Extended Menu for SW 4.XX
To access Extended Menu, press and hold the “ESC” button, switch the power ON and wait
until the menu is opened.
The
“[xxx]”
indicates the choices or range.
The factory default and helpful notes like increments of change are in
italics.
Extended Menu 1 Language:
Here the is language choice. There are standard languages
and place for two local languages that can be uploaded to the HC5500 by a service person.
Note: For Russian, the HC5500 hardware version with Cyrillic text is used.
Extended Menu 2 Unit:
Is for what unit the controller shall use.
Extended Menu 3 Sprayer type:
The basis setup of what kind of sprayer is the HC5500
attached to and what kind of liquid system is mounted on the sprayer.
Extended Menu 4 Data exchange:
Setup of the data communication.
HC5500 can be attached to other units like a PC, printers, variable Rate Application or
remote control. The communication between the HC5500 and the unit has to be set up
correctly.
The setup and use of the com ports are described in the “Software” section of this manual.
Extended Menu 5 Optional sensors:
Setup of optional sensors that can be fitted. It is
typically the pressure, fan revolutions and tank contents (TankGauge).
Extended Menu 6 Service interval:
Setup of the service interval.
Extended Menu 7 Factory settings:
Setup of factory settings
Extended Menu 8 Settings:
Settings of the regulation, tank, track and misc. settings are
done.
Extended Menu 9 JobCom:
Is for setup of the JobCom, TWIN actuators and read out of
the software version and serial number.
Extended Menu 1 Language
E1
Language
[UK, D, DK, F, SF, HU, Local 1, Local 2]
Default is UK.
Local 1 & 2 are languages that can be added with a PC and the “HC 5500 Language config”
software or another HC5500.
Extended Menu 2 Unit
E2
Unit
[Metric, US]