7 - Menu 3 Calibration
7.2
Menu 3.1.1.1 Constant
The theoretical speed constant, pulses per unit (PPU), is the distance in
feet on the circumference of the wheel between holes (or protrusions /
magnets) that the speed sensor records.
Menu 3.1.1.2.1 Practical
Practical calibration of speed is done by driving a measured distance
and correcting the display so that the actual and the calculated
distances are the same. Calibration should take place in the field with a
half full tank and normal working tire pressure in order to obtain the
wheel’s real “working radius”.
Method:
1.
Measure a distance not less than 200 feet.
2.
Park the tractor at the start of the measured distance.
3.
Press #. When zero distance [ 0 ft ] shows, drive the distance.
4.
Press #.
5.
Correct the distance shown on the display with the ¿ or ª to read the actual distance. Alternatively key in on the
numeric keys.
6.
Press # to see the new calculated value.
7.
Press # again to accept the value.
3.1.1.1 Sprayer speed
4 .00
PPU
Shows and permit change to the constant, Pulses Per Unit (metre
/ feet)
3.1.1.2.1
200
Measure up a distance more than 70 metres or 200 feet.
Then drive distance
Содержание HC 6500
Страница 1: ...CONTROLLER HC6500 Instruction book sw 1 2x 67021903 Version 1 20 US 08 2010 ...
Страница 2: ......
Страница 4: ......
Страница 10: ...1 Welcome 1 2 ...
Страница 30: ...4 System setup 4 8 ...
Страница 62: ...8 Menu 4 Toolbox 8 4 Menu 4 4 Reserved Reserved function This menu is not used ...
Страница 70: ...10 Soft keys 10 2 ...
Страница 72: ...11 Maintenance 11 2 ...
Страница 80: ...12 Fault finding 12 8 ...
Страница 89: ...Notes ...
Страница 90: ...Notes ...
Страница 91: ......