6 - Maintenance
34
ATTENTION! The hinge will move forward and backward during
the spray job; make sure that the threaded rod does not come in
contact with the boom. Minimum distance is 5/8” (15mm).
ATTENTION! Make sure that there are threads showing outside of
the jamb nuts. If not you will run the risk of the boom coming free
and swinging forward toward the tractor cab.
Mechanical End Stop
1.
The mechanical end stop (1) must be adjusted so that it is placed
in the middle of the folding arm.
•
Loosen bolt (A) so that the end stop can slide freely.
•
Adjust the position of the end stop by screwing or unscrewing bolt
(B).
•
Tighten counter nut (C).
ATTENTION! Make sure that bolt (B) does not come completely
unscrewed from mechanical stop (1).