5 - Operation
77
Filling Through Tank Lid
Water is filled into the main tank by removing the tank lid located at the top of the sprayer, which is accessible from the
platform. It is recommended to use water as clean as possible for spraying purposes. Always fill water through the strainer
basket to prevent foreign particles from entering the tank. An overhead tank can be used in order to obtain high filling
capacity.
±
WARNING! Do not let the filling hose enter the tank. Keep it
outside the tank, pointing towards the filling hole. If the hose is
led into the tank and the water pressure drops at the water
supply, chemicals may be siphoned back and contaminate the
water supply lines and source.
±
The water supply line should be provided with a check valve as
additional safety precaution. Follow local legislation in force at
any time.
±
The water supply should be provided with a water meter to avoid
spillage by overfilling. Follow local legislation in force at any time.
Main Tank Quick Fill
The main tank is filled via the 3” quick coupler located behind the
TurboFiller:
1.
Remove plug from Quick Fill valve and connect filling hose from
water supply.
2.
Open the Quick Fill valve and fill tank to desired level.
3.
Keep an eye on the main tank level indicator in order not to overfill
the tank.
4.
Close the Quick Fill valve and remove the filling hose.
5.
Replace the plug to the Quick Fill coupler when filling is complete.
Filling of Rinsing Tank
The rinsing tank is filled via the 2” quick coupler at the manifold system:
1.
Remove plug from Quick Fill valve and connect filling hose from
water supply.
2.
Open the Quick Fill valve and fill tank to desired level.
3.
Keep an eye on the level indicator in order not to overfill the tank.
4.
Close the Quick Fill valve and remove the filling hose.
5.
Replace the plug to the Quick Fill coupler when filling is complete.
Capacity: approximately 130 gallons (500 liters).
ATTENTION! Only fill rinsing tank with clean water! To avoid algae developing in the rinsing tank, always drain the
rinsing tank if the sprayer is not in use for a long period of time.
ATTENTION! For cleaning purposes etc. the rinsing tank is also accessible via the tank lid on top of the tank.
Содержание COMMANDER 5500
Страница 2: ......
Страница 4: ......
Страница 10: ...Table of Contents 8 ...
Страница 12: ...1 Welcome 10 ...
Страница 48: ...3 Description 46 ...
Страница 96: ...5 Operation 94 ...
Страница 99: ...6 Maintenance 97 Lubrication and Oiling Plan Boom Width 80 100 10 10 10 C 500 C 50 C 50 10 ...
Страница 100: ...6 Maintenance 98 Lubrication and Oiling Plan Boom Width 120 10 C 500 C 50 10 ...
Страница 129: ...6 Maintenance 127 At the same time adjust the two stop bolts to align the boom sections ...
Страница 142: ...6 Maintenance 140 ...
Страница 162: ...8 Technical Specifications 160 ...
Страница 168: ...Index 166 ...
Страница 169: ......