6 - Maintenance
138
Off-Season Storage
General Info
To preserve the sprayer intact and to protect its components, carry out the following off-season storage program.
Before Storage
When the spraying season is over, you should devote some extra time to the sprayer. If chemical residues are left over in the
sprayer for longer periods, it may reduce the life of its individual components.
1.
Clean the sprayer completely - inside and outside - as described under “Cleaning” on page 86. Make sure that all valves,
hoses and auxiliary equipment have been cleaned with a cleaning agent and flushed with clean water afterwards, so
that no chemical residues are left in the sprayer.
2.
Replace any damaged seals and repair any leaks.
3.
Empty the sprayer completely, and let the pump work for a few minutes. Operate all valves and handles to drain as
much water out off the liquid system as possible. Let the pump run until air comes out of all nozzles. Remember to
drain the rinsing tank also.
4.
Protection against frost:
First complete the cleaning inside and outside the sprayer.
Pour approximately 13 gal. (50 liters) of antifreeze mixture into the main tank. In the mixture, include any remaining
water in the liquid system to create a protective ratio of antifreeze/water solution.
Depending on your winter temperatures, use the recommended mixture ratio in the table below:
Turn on the pump and operate all valves and functions, operating units, TurboFiller etc., allowing the antifreeze mixture
to be distributed around the entire liquid system without leaving any unmixed water in hidden places.
Unmixed water will freeze and possibly damage the sprayer’s components!
Open the operating unit main valve ON/OFF and distribution valves, so that the antifreeze is sprayed through the
nozzles as well. The antifreeze will also prevent O-rings, seals, diaphragms etc. from drying out.
The FlexCapacity pump (if equipped) must also be engaged and flushed.
Empty filters and boom pipes. Remember to unscrew the end plugs, as unmixed water can build up in blind pipe ends
causing a risk of a broken end plug or pipe, when the boom pipes are pressurized at the next spray job.
5.
Remove the glycerine-filled pressure gauges and store them frost-free in a vertical position.
Also dismount the sensor (A) connected to the nozzle pressure
gauge after filling the antifreeze mixture, as this area is a possible
blind end that could result in frost damages.
6.
Lubricate all lubricating points according to the lubricating intervals.
% Water / Antifreeze
Freezing Point
90%
26° F (-3° C)
80%
18° F (-8° C)
70%
7° F (-14° C)
60%
-10° F (-23° C)
50%
-34° F (-37° C)
Содержание COMMANDER 5500
Страница 2: ......
Страница 4: ......
Страница 10: ...Table of Contents 8 ...
Страница 12: ...1 Welcome 10 ...
Страница 48: ...3 Description 46 ...
Страница 96: ...5 Operation 94 ...
Страница 99: ...6 Maintenance 97 Lubrication and Oiling Plan Boom Width 80 100 10 10 10 C 500 C 50 C 50 10 ...
Страница 100: ...6 Maintenance 98 Lubrication and Oiling Plan Boom Width 120 10 C 500 C 50 10 ...
Страница 129: ...6 Maintenance 127 At the same time adjust the two stop bolts to align the boom sections ...
Страница 142: ...6 Maintenance 140 ...
Страница 162: ...8 Technical Specifications 160 ...
Страница 168: ...Index 166 ...
Страница 169: ......