13
NOTE: It is advisable to increase the forward speed (double if pos-
sible) and reduce the pressure. For S4110 nozzles, pressure may
be reduced to 1.5 bar.
2. Select and use the appropriate protective clothing. Select detergent
suitable for cleaning and suitable deactivating agents if necessary.
3. Rinse and clean sprayer and tractor externally. Use detergent if
necessary.
4. Remove tank and suction filters and clean. Be careful not to damage
the mesh. Replace suction filter top. Replace filters when the
sprayer is completely clean.
5. With the pump running, rinse the inside of the tank. Remember the
tank roof. Rinse and operate all components and any equipment
that has been in contact with the chemical. Before opening the
distribution valves and spraying the liquid out, decide whether this
should be done in the field again or on the soakaway.
6. After spraying the liquid out, stop the pump and fill at least 1/5 of the
tank with clean water. Note that some chemicals require the tank to
be completely filled. Add appropriate detergent and/or deactivating
agent, eg. Washing soda or Triple ammonia.
NOTE: If a cleaning procedure is given on the chemical label, follow
it closely.
7. Start the pump and operate all controls enabling the liquid to come
in contact with all the components. Leave the distribution valves
until last. Some detergents and deactivating agents work best if left
in the tank for a short period. Check the label.
If fitted the Self-Cleaning Filter can be flushed by removing the
bypass hose from the bottom of the filter. Stop the pump and re-
move the hose. Start the pump for a few seconds to flush filter. Be
careful not to loose the restrictor nozzle.
8. Drain the tank and let pump run dry. Rinse inside of tank, again
letting the pump run dry.
9. Stop the pump. If the pesticides used have a tendency to block
nozzles and filters, remove and clean them now. Check also for
sediment on the pressure side of the safety valve for the Self-Clean-
ing Filter.
10. Replace all the filters and nozzles and store the sprayer. If, from
previous experiences, it is noted that the solvents in the pesticide
are particularly aggressive, store the sprayer with the tank lid open.
NOTE: If the sprayer is cleaned with a high pressure cleaner we
recommend lubrication of the entire machine.
Содержание Boss Series
Страница 1: ...BOSS HERON Instruction book 673791 GB 04 2002 www hardi international com...
Страница 18: ...16 1 X 40 2 A X 8 A X 40 3 X 40 17 6 9 T200 0001...
Страница 19: ...17 4 X 40 5 X 40 X 1000 or once a year 16 16 HR only...
Страница 47: ...45 1202 foot A10...
Страница 48: ...46 A12 1302 foot...
Страница 49: ...47 Unit BK 180K 92 B9...
Страница 50: ...48 B10 Distributor BK180K 92...
Страница 51: ...49 Damper HJ73 B300...
Страница 52: ...50 D2 SB 6 8 10 m...
Страница 53: ...51 Boom tube TRIPLET SNAP FIT D904...
Страница 54: ...52 H106 PS 300...
Страница 55: ...53 TPS 800 H107...
Страница 56: ...54 H108 PU TPS 800...
Страница 58: ...56...
Страница 60: ...HARDI INTERNATIONAL A S Helgesh j All 38 DK 2630 Taastrup DENMARK...