The nations #1 manufacturer of hospital cribs

Home Care Warranty

Return Policy

Acceptance of returns on all new and unused equipment and parts is at the discretion of HARD    
Manufacturing. The purchaser will be responsible for a restocking fee and the freight costs associated 
with returning the equipment or item.

Replacement of any part under warranty is contingent upon the following:

1. The customer is to provide the serial number of the crib or bed as well as the serial number of the       
defective or damaged part(s) if one exists. If the part is a mattress, the customer must supply the  

    

serial number of the mattress as well as photos of both tags on the mattress. 
2. The customer is to provide photos of the defective or damaged part.
3. The customer must, if requested by HARD Manufacturing, return the defective or damaged item for  
     inspection prepaid within 30 days of reporting the issue.

Maintenance

Placing cribs and youth beds in cart washers and/or the use of steam spray guns for disinfecting is 
not recommended. Use a non-abrasive cleaning solution such as a mild detergent and thoroughly 
dry all components of crib or bed prior to replacing the mattress on the unit. Solvents containing 
alcohol, ammonia or other abrasives should be avoided. Failure to follow the suggested cleaning/dry-
ing instructions could lead to premature corrosion and require replacement of the mattress.

Expected Service Life of HARD Manufacturing Cribs or Beds is 9 years.

Five (5) year warranty 

HARD Manufacturing will replace at no cost to the purchaser any expendable component  such as, 
but not limited, to mattresses, trigger assemblies, slide rods or slide rod components, crank 
handles, Johns Hopkins handles, vinyl curtains, curtain rods, or IV components found to have a defect 
in materials or workmanship within one (1) year from the date of purchase at our discretion. 

One (1) year warranty

HARD Manufacturing will replace at no cost to the purchaser any motor, sta

  control or under 

bed control box found to be defective within two (2) years from the date of purchase.

Electrical Components

Terms and Conditions of the Warranty Period

The warranty covers normal use of our cribs or youth beds. It does not cover damage or defects that 
occur due to any of the following:
1. Abuse, misuse, mishandling and excessive wear by sta

 , patients or parents/caregivers. 

2. Modi

 cations of the equipment including the electrical equipment. The covers should never be 

removed on the motors, transformers, control boxes, scale controls or sta

  controls. Doing any type        

of modi

 cation to our cribs or youth beds will void the warranty.

E

 ective 6/1/2017

Revised 2020.1  3.26.2020

HARD Manufacturing will replace at no cost to the purchaser any non-expendable component such 
as the head and foot end assemblies, side assemblies or mattress platform found to have a defect in 
materials or workmanship within 

 ve (5) years from the date of purchase at our discretion. 

Содержание H1943-CGP

Страница 1: ...Revised 2020 1 6 12 2020 MODELS H1943 CGP H1955 KGP H1975 MGP HOME CARE SPRINGFIELD CRIB CAREGIVER INFORMATION The nations 1 manufacturer of hospital cribs ASSEMBLY INSTRUCTIONS ...

Страница 2: ...nd beds for up to 12 years from the date of manufacture as long as we still make the part or can obtain it from our vendors HARD Manufacturing cribs and beds can be cleaned with an anti bacterial all purpose cleaner of the parent caregiver choice but it must be a non abrasive cleaner Anything containing bleach alcohol or ammonia must be avoided The crib should be dried thoroughly with a soft cloth...

Страница 3: ...mly and properly If the trigger mechanism for the side rail fails to lock into place properly call the durable medical equipment provider who supplied your child with the crib and ask for servce SIDE RAIL OPERATION SAFETY To prolong the life of the trigger assembly in the side rail continue to squeeze the trigger mechansim as you lower the rail to the desired height and not release until that time...

Страница 4: ...t bar make sure that the red tips of the trigger mechanisms securely lock into place in the notches on both sides of the slide rods You should barely be able to see any of the red tip of the trigger mechanism There should also be an audible click on both ends and if you grasp the lift bar and tug it should not move if it is correctly and securely latched Lift Bar Operation Safety If one of the tri...

Страница 5: ... any further it will only put stress on the crank handle components and eventually cause them to break The Head Crank Handle The foot crank handle is located on the right side of the foot end of your crib The foot crank handle when not in use should be tucked in This helps to avoid damage from it hitting or getting caught on other objects when the crib is being moved To use the foot crank handle p...

Страница 6: ...o make sure nothing was damaged during transport Locate the hardware bag that is packed in the box with the crib ends sides Suggested tools for assembly Philips Screwdriver Rubber Mallet Qty 4 Part 11750 1 2 Plastic Spacer To be used at the bottom of the slide rod Qty 4 Part 63838 1 4 20x7 8 Screw To be used at the top of the slide rod for the rails Qty 4 Part 11531 Washer To be used at the top of...

Страница 7: ...be used halfway down on the slide rods at the lug Part 11556 Nylon Washer To be used halfway down on the slide rods at the lug Part 63454 Lockwasher To be used halfway down on the slide rods at the lug Part 62068 Acorn Nut To be used halfway down on the slide rods at the lug ...

Страница 8: ...seat the mattress platform into the corner locks tap the four corners of the platform with the rubber mallet being careful not to bend or damage the platform or metal pans of the mattress surface End Assembly Pegs from the mattress platform are fully seated into the corner locks as shown Corner Lock End Assembly Mattress Platform Corner Locks ...

Страница 9: ...ps onto the slide rods Do not put the top curtain rod on at this time At the top of both slide rods place a white metal stop ring approximately 1 1 1 2 from the top of the slide rod the stop ring can be placed over the top most notch in the slide rods and fasten with an Allen Key Do not fasten too tightly as they may need to be adjusted once the crib is assemblied See close up photo on next page f...

Страница 10: ...r to the tops of the slide rods but do not completely fasten at this time ASSEMBLY INSTRUCTIONS CONTINUED Plastic Spacer Bumper Spring Bumper Washers Lower Crib Eye Screw Washer Upper Crib Eye Stop Ring 7 Halfway down the slide rod and the end assemblies there is a tab called a lug Line up the slide rod lug with the one on the end assembly and fasten with the screw and washer on the outside and th...

Страница 11: ...ers of these beds place them in the following categories To avoid overheating the motor after raising and lowering the bed three full times in successions HARD Manufacturing Company requires a fifteen minute break before repeating the same Equipment not suitable for use in the presence of fammable anaesthetic mixture with air or oxygen or nitrous oxide The nations 1 manufacturer of hospital cribs ...

Страница 12: ...replacement of the mattress Expected Service Life of HARD Manufacturing Cribs or Beds is 9 years Five 5 year warranty HARD Manufacturing will replace at no cost to the purchaser any expendable component such as but not limited to mattresses trigger assemblies slide rods or slide rod components crank handles Johns Hopkins handles vinyl curtains curtain rods or IV components found to have a defect i...