6
Press
BATTERY TYPE button
and hold for 3 seconds to go into your battery type
selection mode, the battery type you select will be shown on the LCD meter, the default
setting is AGM Battery; the controller will automatically memorize your battery type
setting.
Li-ion battery shown in LCD indicates 3-SERIES Li-ion battery shown as below:
-- Lithium Cobalt Oxide LiCoO2 (LCO) battery
-- Lithium Manganese Oxide LiMn2O4 (LMQ) battery
-- Lithium Nickel Manganese Cobalt Oxide LiNiMnCoO2 (NMC) battery
-- Lithium Nickel Cobalt Aluminum Oxide LiNiCoAlo2 (NCA) battery
LiFePO4 battery shown in LCD indicates Lithium Iron Phosphate battery, LFP battery.
LTO battery shown in LCD indicates Lithium Titanate Oxide, Li4Ti5O12 battery.
Caution: Incorrect battery type setting may damage your battery.
When the controller powers on, the unit will run self-qualify mode and automatically show
below items on LCD before going into charging process
Self-test starts, digital meter segments test
Software version test
Rated voltage and current test
External battery temperature sensor test (if connected)
After going into charging process, the LCD displays the charging statues as below:
Press
VOLT / AMP button
in sequence, the LCD will display in turn with
Battery Voltage, Charging Current, Charged capacity (Amp-hour) and Battery
Temperature (if external temperature sensor connected)
Display in the day time
-
Display during the night
-
Display when battery fully charged
Press
VOLT / AMP button
in sequence, the LCD will display in turn with
Battery Voltage, Charging Current, if you do not press the button, the LCD will
alternatively display the FUL and VOLT or FUL and AMP every 2 seconds