Set up
read the enTire iMpOrTanT SaFeTy inFOrMaTiOn section at the beginning of this manual
including all text under subheadings therein before set up or use of this product.
TO preVenT SeriOuS inJury:
Operate only with proper spark arrestor installed.
Operation of this equipment may create sparks that can start fires around dry vegetation.
a spark arrestor may be required.
The operator should contact local fire agencies for laws or regulations
relating to fire prevention requirements.
Grounding
1. The Generator must be properly grounded in accordance with all relevant electrical codes and standards
before operation. Have the unit grounded by a qualified electrician if you are not qualified to do so.
2. To ground the Generator, connect a #10 AWG grounding wire (not included) from the Grounding
Terminal on the side of the unit to a grounding rod (not included). The grounding rod must be an
earth-driven copper or brass rod (electrode) which can adequately ground the Generator.
3. Refer to local regulations for ground source information.