GeneraL eMiSSiOnS WarranTy COVeraGe

a)  The warranty period begins on the date the engine or equipment is delivered to an ultimate purchaser. The warranty period is 

two years.

b)  HFT warrants to the initial owner and each subsequent owner that the engine is:

1.  Designed, built, and equipped so as to conform with all applicable regulations adopted by the Air Resources Board; and
2.  Free from defects in materials and workmanship that causes the failure of a warranted part for a period of two years.

c)  The warranty on emissions-related parts is as follows:

1.  Any warranted part that is not scheduled for replacement as required maintenance in the written instructions provided, 

is warranted for the warranty period stated above. If any such part fails during the period of warranty coverage, it will be 

repaired or replaced HFT.  Any such part repaired or replaced under the warranty will be warranted for the remaining 

warranty period. 

2.  Any warranted part that is scheduled only for regular inspection in the written instructions is warranted for the warranty 

period stated above. A statement in the written instructions to the effect of “repair or replace as necessary” does not 

reduce the period of warranty coverage.  Any such part repaired or replaced under warranty will be warranted for the 

remaining warranty period. 

3.  Any warranted part that is scheduled for replacement as required maintenance in the written instructions will be 

warranted for the period of time prior to the first scheduled replacement point for that part. If the part fails prior to the first 

scheduled replacement, the part will be repaired or replaced by HFT. Any such part repaired or replaced under warranty 

will be warranted for the remainder of the period prior to the first scheduled replacement point for the part. 

4.  Repair or replacement of any warranted part under the warranty will be performed at no charge to the owner at a retail 

store or by HFT paying for shipping the product for repair. 

5.  Notwithstanding the provisions herein, warranty services or repairs will be provided at all retail stores or by contacting 

HFT product support at 1-888-866-5797 or [email protected]

6.  The owner will not be charged for diagnostic labor that leads to the determination that a warranted part is in fact 

defective, provided that such diagnostic work is performed at a retail store.

7.  HFT is liable for damages to other engine components proximately caused by a failure under warranty of any warranted 

part. 

8.  Throughout the emissions warranty period stated above, HFT will maintain a supply of warranted parts sufficient to meet 

the expected demand for such parts. 

9.  Any replacement part may be used in the performance of any warranty maintenance or repairs and will be provided 

without charge to the owner. Such use will not reduce the warranty obligations of HFT.

10.  Add-on or modified parts that are not approved by HFT may not be used. The use of any non-exempted add-on or 

modified parts will be grounds for disallowing a warranty claim. HFT is not liable to warrant failures of warranted parts 

caused by the use of a non-exempted add-on or modified part.

d)  Emission Warranty Parts List.

1.  Fuel Metering System

a.  Carburetor and its internal parts (and/or pressure 

regulator or fuel injection system).

b.  Fuel tank.
c.  Cold start enrichment system.
d.  Air/fuel ratio feedback and control system.

2.  Air Induction System

a.  Controlled hot air intake system.
b.  Intake manifold.
c.  Air filter.

3.  Ignition System

a.  Spark plugs.
b.  Magneto ignition system.
c.  Spark advance/retard system.

4.  Catalyst System (if so equipped)

a.  Exhaust pipe stud/exhaust manifold.
b.  Thermal reactor.
c.  Catalytic converter (if so equipped).

5.  Particulate Controls

a.  Traps, filters, precipitators, and any other device used 

to capture particulate emissions.

6.  Miscellaneous Items Used in Above Systems

a.  Vacuum, temperature and time sensitive valves and 

switches.

b.  Hoses, belts, connectors, and assemblies.

7.  Evaporative Emission Control System

a.  Fuel tank.
b.  Fuel caps, valves, canisters, filters, vapor hoses, 

clamps, connectors, belts, and assemblies.

HFT provides with each product written instructions for the maintenance and use of the product by the owner.

Содержание Storm Cat 60338

Страница 1: ...dry place for future reference using a generator indoors Can KiLL yOu in MinuTeS Generator exhaust contains carbon monoxide This is a poison you cannot see or smell neVer use inside a home or garage eVen iF doors and windows are open Only use OuTSiDe and far away from windows doors and vents When unpacking make sure that the product is intact and undamaged If any parts are missing or broken please...

Страница 2: ...stabilizer treated unleaded gasoline mixed with 2 cycle oil see below Capacity 1 1 Gallon Oil Type 2 cycle oil designed specifically for mixing with gasoline Ratio 50 1 gasoline to oil ratio 2 5 oz oil per gallon of gasoline Run Time 50 Load with full tank 5 hr Sound Level at feet 82 dB Rotation viewed from PTO power takeoff the output shaft Counterclockwise Spark Plug Type BONON F5TC Gap 0 028 0 ...

Страница 3: ...ry Wear ANSI approved safety goggles with side shields Read the manual before set up and or use WARNING marking concerning Risk of Hearing Loss Wear hearing protection Symbol Property or Statement WARNING marking concerning Risk of Respiratory Injury Operate engine OUTSIDE and far away from windows doors and vents WARNING marking concerning Risk of Fire while handling fuel Do not smoke while handl...

Страница 4: ...ack up power 10 Do not operate the Generator before grounding The Generator must be earth grounded in accordance with all relevant electrical codes and standards before operation Operating Precautions 1 CARBON MONOXIDE HAZARD Using a generator indoors CAN KILL YOU IN MINUTES Generator exhaust contains carbon monoxide This is a poison you cannot see or smell NEVER use inside a home or garage EVEN I...

Страница 5: ... near the engine s magneto or recoil starter 26 Use only accessories that are recommended by Harbor Freight Tools for your model Accessories that may be suitable for one piece of equipment may become hazardous when used on another piece of equipment 27 Do not operate in explosive atmospheres such as in the presence of flammable liquids gases or dust Gasoline powered engines may ignite the dust or ...

Страница 6: ...uring service 6 Maintain labels and nameplates on the equipment These carry important information If unreadable or missing contact Harbor Freight Tools for a replacement 7 Have the equipment serviced by a qualified repair person using only identical replacement parts This will ensure that the safety of the equipment is maintained Do not attempt any service or maintenance procedures not explained i...

Страница 7: ...lating to fire prevention requirements Grounding 1 The Generator must be properly grounded in accordance with all relevant electrical codes and standards before operation Have the unit grounded by a qualified electrician if you are not qualified to do so 2 To ground the Generator connect a 10 AWG grounding wire not included from the Grounding Terminal on the side of the unit to a grounding rod not...

Страница 8: ...MPORTANT Your Warranty is VOID if the Engine s Fuel Tank is not filled with the proper mixture 50 1 of stabilizer treated unleaded gasoline and 2 cycle oil before each use Before each use check the fuel level Do not run the Engine with an improper unleaded gasoline 2 cycle oil mixture Running the Engine with an improper mixture WILL permanently damage the Engine 1 GALLON STABILIZER TREATED UNLEADE...

Страница 9: ... s carburetor Then pull the Starter Handle gently until resistance is felt Allow Cable to retract fully and then pull it quickly Repeat until the engine starts Note Do not let the Starter Handle snap back against the engine Hold it as it recoils so it doesn t hit the engine 5 Allow the Engine to run for several seconds Then if the Choke lever is in the START position move the Choke Lever very slow...

Страница 10: ...nd extension cords draw additional power Keep cord length at a minimum Wattage Estimates Wattages listed below are estimates for that type of equipment only Check nameplate wattages on all loads before connecting to Generator This Unit Can Power Any One of the Following Items Running Watts Peak Watts Camping 50 700 Tailgating 50 700 Radio 50 200 Table Box Fan 200 15 Amp Battery Charger 380 Outdoor...

Страница 11: ...llowing procedures are in addition to the regular checks and maintenance explained as part of the regular operation of the engine and equipment Procedure Before Each Use Monthly or every 20 hr of use Every 3 mo or 50 hr of use Every 6 mo or 100 hr of use Yearly or every 300 hr of use Every 2 Years Brush off outside of engine Check engine fuel oil mixture level Check air cleaner Check sediment cup ...

Страница 12: ...dust mask respirator and heavy duty work gloves In a well ventilated area away from bystanders use pressurized air to blow dust out of the filter For foam filters Wash the filter in warm water and mild detergent several times Rinse Squeeze out excess water and allow it to dry completely Soak the filter in lightweight oil briefly then squeeze out the excess oil 3 Install the cleaned filter s Secure...

Страница 13: ...3 LUBRICATION a Clean out area around spark plug Remove spark plug and pour one tablespoon of engine oil into cylinder through spark plug hole b Replace spark plug but leave spark plug cap disconnected c Pull Starter Handle to distribute oil in cylinder Stop after one or two revolutions when you feel the piston start the compression stroke when you start to feel resistance 4 STORAGE AREA Cover and...

Страница 14: ...uire further cleaning 7 Gently tap side of carburetor float chamber with screwdriver handle 8 Turn Choke to RUN position Remove spark plug and pull the start handle several times to air out the chamber Reinstall spark plug and set Choke to START position 9 Replace Fuel Filter IGNITION SPARK RELATED 1 Spark plug cap not connected securely 2 Spark plug electrode wet or dirty 3 Incorrect spark plug g...

Страница 15: ... quality gasoline oil mixture 2 Engine overloaded 3 Incorrect spark timing deposit buildup worn engine or other mechanical problems 1 Fill fuel tank with fresh 87 octane stabilizer treated unleaded gasoline oil mixture Do not use gasoline with more than 10 ethanol E15 E20 E85 etc 2 Do not exceed equipment s load rating 3 Have qualified technician diagnose and service engine Engine backfires 1 Impu...

Страница 16: ... Round Head Bolt M6 x 16 2 40 Flywheel 1 41 Flange Nut M10 x 1 25 1 Part Description Qty 42 Recoil Starter Assy 1 43 Intake Valve Gasket 1 44 Intake Valve Assy 1 45 Flange Bolt M6 x 20 4 46 Stud AM6 x 60 2 47 Intake Gasket 1 48 Carburetor 1 49 Carburetor Gasket B 1 50 Carburetor Gasket A 1 51 Supporting Plate 1 52 Compression Spring 1 53 Cross Round Head Bolt M6 x 40 1 54 Rod Link 1 55 Tension Spr...

Страница 17: ...Page 17 For technical questions please call 1 888 866 5797 ITEM 60338 Safety Setup Operation Maintenance Assembly Diagram ...

Страница 18: ...plain the emissions control system warranty on your 2016 Small Off Road Engine in addition to the Retail Warranty above In California new equipment that uses small off road engines must be designed built and equipped to meet the State s stringent anti smog standards HFT must warrant that the emissions control system on your engine will be free from defects in material and workmanship for two 2 yea...

Страница 19: ...r shipping the product for repair 5 Notwithstanding the provisions herein warranty services or repairs will be provided at all retail stores or by contacting HFT product support at 1 888 866 5797 or productsupport harborfreight com 6 The owner will not be charged for diagnostic labor that leads to the determination that a warranted part is in fact defective provided that such diagnostic work is pe...

Страница 20: ...O THE BUYER THAT HE OR SHE IS QUALIFIED TO MAKE ANY REPAIRS TO THE PRODUCT OR THAT HE OR SHE IS QUALIFIED TO REPLACE ANY PARTS OF THE PRODUCT IN FACT THE MANUFACTURER AND OR DISTRIBUTOR EXPRESSLY STATES THAT ALL REPAIRS AND PARTS REPLACEMENTS SHOULD BE UNDERTAKEN BY CERTIFIED AND LICENSED TECHNICIANS AND NOT BY THE BUYER THE BUYER ASSUMES ALL RISK AND LIABILITY ARISING OUT OF HIS OR HER REPAIRS TO...

Отзывы: