11.  Improper connections to a building electrical system 

can allow electrical current from the Generator 

to backfeed into the utility lines.  Such backfeed 

may electrocute utility company workers or others 

who contact the lines during a power outage, and 

the Generator may explode, burn, or cause fires 

when utility power is restored.  Consult the utility 

company and a qualified electrician if intending 

to use the Generator for back up power.

12. Do not operate the Generator before grounding.  

The Generator must be earth-grounded 

in accordance with all relevant electrical 

codes and standards before operation.

13. Install carbon monoxide alarm(s) with 

battery backup in nearby buildings according 

to manufacturer’s instructions.

Operating precautions

1. 

 

 

CARBON MONOXIDE HAZARD  

 

 

USING A GENERATOR INDOORS  

 

 

CAN KILL YOU IN MINUTES. 

  

Generator exhaust contains carbon 

monoxide.  This is a poison you cannot see or smell.

 

NEVER use inside a home or garage, EVEN IF 

doors and windows are open.

 

Only use OUTSIDE and far away from 

windows, doors, and vents.

2. 

CARBON MONOXIDE SHUTOFF

DANGER! TO pREVENT SERIOUS 

INJURY AND DEATH FROM 

CARBON MONOXIDE INHALATION: 

The Carbon Monoxide sensor is an additional 

layer of protection only.  Do not use the 

Generator in any area or situation that will 

allow carbon monoxide to accumulate.

•  FLASHING RED LIGHT: 

Dangerous levels of carbon monoxide gas have 

built up and generator will shutoff.   

Leave immediately until area has aired 

out. Move Generator to well-ventilated 

area before operation.

•  FLASHING YELLOW LIGHT: 

Carbon monoxide sensor malfunction. 

Sensor needs service.  Do not use the 

Generator until the sensor is working 

properly.  For technical questions, 

please call 1-888-866-5797.

NOTE: Yellow light flashes once after 

starting to indicate passing self-check 

and is functioning normally. 

Carbon Monoxide sensor must only be serviced 

by qualified technician to restore it to original 

settings.  Do not modify or tamper with the 

Carbon Monoxide sensor. Not following these 

instructions can result in death or serious injury 

due to Carbon Monoxide sensor malfunction.

3.  Never use a generator indoors, including in 

garages, basements, crawlspaces and sheds.  

Opening doors and windows or using fans will NOT 

prevent carbon monoxide build up in the home.

4.  When using generators, keep them outdoors 

and far away from open doors, windows, 

and vents to avoid toxic levels of carbon 

monoxide from building up indoors.

5.  If you start to feel sick, dizzy, or weak while 

using a generator, get to fresh air right away.  

The carbon monoxide from generators can 

quickly lead to full incapacitation and death.

6.  Keep children away from the equipment, 

especially while it is operating. 

7.  Keep all spectators at least six feet 

from the Engine during operation.

8.  Do not touch engine during use.  

Let engine cool down after use. 

9.  Never store fuel or other flammable 

materials near the engine.

10. Fire Hazard! Do not fill gas tank while engine is 

running.  Do not operate if gasoline has been spilled.  

Clean spilled gasoline before starting engine. 

Do not operate near pilot light or open flame.

11.  If the plugged-in product operates abnormally 

or unusually slow, immediately stop using the 

Generator as a power source.  Always read and 

adhere to the instruction manual of the product 

to be powered, to make sure that it can be safely 

and efficiently powered by a portable generator.  

Set up precautions (continued)

Содержание PREDATOR 59206

Страница 1: ...o do so can result in serious injury SAVE THIS MANUAL Visit our website at http www harborfreight com Email our technical support at productsupport harborfreight com Email our engine support at predat...

Страница 2: ...e use of a special tool or lock and key or other means of security and shall be controlled by the authority responsible for the location 2 Gasoline fuel and fumes are flammable and potentially explosi...

Страница 3: ...de sensor malfunction Sensor needs service Do not use the Generator until the sensor is working properly For technical questions please call 1 888 866 5797 NOTE Yellow light flashes once after startin...

Страница 4: ...re the Generator on transport vehicles to prevent the tool from rolling slipping and tilting 23 Industrial applications must follow OSHA requirements 24 Do not leave the Generator unattended when it i...

Страница 5: ...ion Do not modify the generator or its engine and do not use the generator for a purpose for which it is not intended 43 Extension Cord Make sure your extension cord is in good condition When using an...

Страница 6: ...rrectly 9 Store equipment out of the reach of children 10 Follow scheduled engine and equipment maintenance GFCI Protection This Generator is equipped with two 3 Prong duplex 120V ground fault circuit...

Страница 7: ...ne Recommended fill level 8 Gallons Engine Oil Type SAE 10W 30 above 32 F 5W 30 at 32 F or below Capacity 1 16 Quart Spark Plug Type NHSP Torch F7TC Gap 0 028 0 031 Valve Clearance Intake 0 004 0 006...

Страница 8: ...volt or 240 volt that is compatible with the electrical characteristics and rated capacities of the tools and equipment being used 3 ON OFF Circuit Breakers The circuit breaker protects the Generator...

Страница 9: ...ended to power sensitive electronic equipment without the addition of an appropriate line conditioner and surge protector both not included Sensitive electronic equipment includes but is not limited t...

Страница 10: ...ns are as follows Use one of the following as the grounding electrode Pipe or conduit minimum in diameter minimum 8 ft long If steel it must have anti corrosion coating Rod stainless steel or copper o...

Страница 11: ...plate c Remove the nuts to allow the air cleaner housing to be moved aside Air Cleaner Housing Nuts Deflecting Plate Foam Filter Air Cleaner Cover 4 Place a bowl under the fuel cup to catch any spille...

Страница 12: ...questions please call 1 888 866 5797 ITEM 59206 Safety Setup Operation Maintenance High Altitude Kit Parts List A Part Description Qty 1a Main Jet 3000 6000 ft 1 2a Main Jet 6000 8000 ft 1 3a Bolt Sea...

Страница 13: ...t threading it in and remove it to check the oil level The oil level should be up to the full level as shown above 5 If the oil level is at or below the low mark add the appropriate type of oil until...

Страница 14: ...If above test fails do not use receptacle until it is repaired or replaced d Press Reset button in for use RESET TEST RESET TEST Reset Button Test Button 120 Volt GFCI Receptacle 4 Plug in products 5...

Страница 15: ...t the engine can stabilize For MANUAL START A Turn the Engine Switch to ON B Grip the Starter Handle of the Engine loosely and pull it slowly several times to allow the gasoline to flow into the Engin...

Страница 16: ...er exceed the rated capacity for this Generator as serious damage to the Generator and or appliances tools and equipment could result from an overload Starting and running wattage requirements should...

Страница 17: ...r that only supplies the exact watts needed To Calculate Wattage Volts and amps can be multiplied together to get watts volts x amps watts To Calculate Additional Start Up Watts If They Are Not Listed...

Страница 18: ...gine in an emergency turn the Engine Switch off NOTICE Generator shut off under load may damage the Generator and attached equipment Stopping the Engine Under Normal Conditions 1 Before turning off th...

Страница 19: ...qualified technician service the equipment instead Cleaning Maintenance and Lubrication Note This maintenance schedule is intended solely as a general guide If performance decreases or if equipment o...

Страница 20: ...Remove the drain plug and if possible tilt the crankcase slightly to help drain the oil out Recycle used oil 5 Replace the drain plug and tighten it 6 Clean the top of the Dipstick and the area around...

Страница 21: ...de the spark plug can be damaged 5 Install the new spark plug or the cleaned spark plug into the engine Gasket style Finger tighten until the gasket contacts the cylinder head then about 1 2 2 3 turn...

Страница 22: ...uretor and carefully remove the Drain Bolt from the bottom of the Carburetor Bowl allowing the fuel to drain completely Replace the Drain Bolt after draining WARNING To prevent serious injury and fire...

Страница 23: ...ilter IGNITION SPARK RELATED 1 Power Switch at OFF position 2 Spark plug cap not connected securely 3 Spark plug electrode wet or dirty 4 Incorrect spark plug gap 5 Spark plug cap broken 6 Circuit bre...

Страница 24: ...y operate generator outside 2 Carbon monoxide sensor malfunction Sensor needs service Call 1 888 866 5797 as soon as possible Do not use the Generator until the sensor is working properly 3 Make sure...

Страница 25: ...er Plug in product and turn on 3 Turn off and unplug product Test GFCI receptacle If functioning properly reset GFCI plug in product and turn on 4 Have product repaired Product begins to operate abnor...

Страница 26: ...ASSEMBLY DIAGRAM IN THIS MANUAL AS A REFERENCE TOOL ONLY NEITHER THE MANUFACTURER OR DISTRIBUTOR MAKES ANY REPRESENTATION OR WARRANTY OF ANY KIND TO THE BUYER THAT HE OR SHE IS QUALIFIED TO MAKE ANY...

Страница 27: ...l Series 2 52 Wire Clip 1 53 Coil Subassembly Charge 1 54 Hex Socket Flange Face Bolt Small Series 2 55 Coil Ignition 1 56 Bolt 2 Part Description Qty 57 Clamp Charge Coil 1 58 Hex Socket Flange Face...

Страница 28: ...amp 1 141 Pipe Clamp 1 142 Pipe Clamp 1 143 Tube Fuel 1 144 Jacket Rubber 1 145 Cock Assy Fuel 1 146 Bolt 2 147 Crosspiece Subassembly 1 Part Description Qty 148 Bolt 1 149 Support Atr Cleaner 1 150 S...

Страница 29: ...64 65 66 67 67 68 68 69 70 71 72 71 74 75 76 78 77 73 80 82 83 84 79 81 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 107 108 105 106 109 110 111 112 113 114 115 116 117 119 118 120...

Страница 30: ...the exclusion or limitation of incidental or consequential damages so the above limitation of exclusion may not apply to you THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLI...

Страница 31: ...of components of the emissions control system and are covered by this two 2 year warranty For a full list of emissions control components covered by this warranty please see 40 CFR 1068 Appendix I 1...

Страница 32: ...26677 Agoura Road Calabasas CA 91302 1 888 866 5797...

Отзывы: