background image

Page 22

For technical questions, please call 1-888-866-5797.

ITEM 59206 

        

SAFETY

SETU
p

Op
ERA
TION

M

AINTENANCE

Long-Term Storage

When the equipment is to remain idle for longer than 

20 days, prepare the Engine for storage as follows:
1. 

CLEANING

Wait for Engine to cool, then clean Engine with 

dry cloth.  

NOTICE:

  

Do not clean using water.

  

The water can cause rust damage over time.  Apply 

a thin coat of rust preventive oil to all metal parts.

2. 

FUEL: 

Gasoline Treatment/Draining the Fuel Tank 

 

To protect the fuel tank during storage, fill the 

tank with fresh gasoline that has been treated 

with a fuel stabilizer additive.  Follow fuel 

stabilizer manufacturer’s recommendations 

for use.  Refer to Checking and Filling Fuel 

Checking and Filling Fuel on page  11.

Aged gasoline that has not been treated with 

stabilizer ahead of time must be safely drained 

away and not run through the engine.

WARNING!

 

TO pREVENT SERIOUS 

INJURY FROM FIRE:

 

Fill tank in a well-ventilated area away 

from ignition sources.  If the engine 

is hot from use, shut the engine off and 

wait for it to cool before adding fuel.  Do not smoke. 

 

Draining the Carburetor

After closing the Fuel Valve, place an appropriate 

container under the Carburetor and carefully 

remove the Drain Bolt from the bottom of the 

Carburetor Bowl, allowing the fuel to drain 

completely.  Replace the Drain Bolt after draining.

WARNING! To prevent serious 

injury and fire, close the Fuel Valve 

before draining the Carburetor.

3. 

LUBRICATION:

a.  Change engine oil.
b.  Clean out area around spark plug.  

Remove spark plug and pour one tablespoon of 

engine oil into cylinder through spark plug hole.

c.  Replace spark plug, but leave 

spark plug cap disconnected.

d.  Pull Starter Handle to distribute oil in cylinder.  

Stop after one or two revolutions when you 

feel the piston start the compression stroke 

(when you start to feel resistance).

4. 

STORAGE AREA: 

Cover and store in a dry, level, well-ventilated 

area out of reach of children.  Storage area should 

also be away from ignition sources, such as 

water heaters, clothes dryers, and furnaces.

5.  Avoid direct exposure to rain and sunlight.

NOTICE:

 During extended storage periods the 

Engine must be started every 3 months and allowed 

to run for 15 – 20 minutes or the Warranty is VOID. 
6. 

AFTER STORAGE: 

Before starting the Engine during or after 

storage, keep in mind that untreated gasoline 

will deteriorate quickly.  Drain the fuel 

tank and change to fresh fuel if untreated 

gasoline has been sitting for a month, if 

treated gasoline has been sitting beyond the 

fuel stabilizer’s recommended time period, 

or if the Engine does not start.

Содержание PREDATOR 59206

Страница 1: ...o do so can result in serious injury SAVE THIS MANUAL Visit our website at http www harborfreight com Email our technical support at productsupport harborfreight com Email our engine support at predat...

Страница 2: ...e use of a special tool or lock and key or other means of security and shall be controlled by the authority responsible for the location 2 Gasoline fuel and fumes are flammable and potentially explosi...

Страница 3: ...de sensor malfunction Sensor needs service Do not use the Generator until the sensor is working properly For technical questions please call 1 888 866 5797 NOTE Yellow light flashes once after startin...

Страница 4: ...re the Generator on transport vehicles to prevent the tool from rolling slipping and tilting 23 Industrial applications must follow OSHA requirements 24 Do not leave the Generator unattended when it i...

Страница 5: ...ion Do not modify the generator or its engine and do not use the generator for a purpose for which it is not intended 43 Extension Cord Make sure your extension cord is in good condition When using an...

Страница 6: ...rrectly 9 Store equipment out of the reach of children 10 Follow scheduled engine and equipment maintenance GFCI Protection This Generator is equipped with two 3 Prong duplex 120V ground fault circuit...

Страница 7: ...ne Recommended fill level 8 Gallons Engine Oil Type SAE 10W 30 above 32 F 5W 30 at 32 F or below Capacity 1 16 Quart Spark Plug Type NHSP Torch F7TC Gap 0 028 0 031 Valve Clearance Intake 0 004 0 006...

Страница 8: ...volt or 240 volt that is compatible with the electrical characteristics and rated capacities of the tools and equipment being used 3 ON OFF Circuit Breakers The circuit breaker protects the Generator...

Страница 9: ...ended to power sensitive electronic equipment without the addition of an appropriate line conditioner and surge protector both not included Sensitive electronic equipment includes but is not limited t...

Страница 10: ...ns are as follows Use one of the following as the grounding electrode Pipe or conduit minimum in diameter minimum 8 ft long If steel it must have anti corrosion coating Rod stainless steel or copper o...

Страница 11: ...plate c Remove the nuts to allow the air cleaner housing to be moved aside Air Cleaner Housing Nuts Deflecting Plate Foam Filter Air Cleaner Cover 4 Place a bowl under the fuel cup to catch any spille...

Страница 12: ...questions please call 1 888 866 5797 ITEM 59206 Safety Setup Operation Maintenance High Altitude Kit Parts List A Part Description Qty 1a Main Jet 3000 6000 ft 1 2a Main Jet 6000 8000 ft 1 3a Bolt Sea...

Страница 13: ...t threading it in and remove it to check the oil level The oil level should be up to the full level as shown above 5 If the oil level is at or below the low mark add the appropriate type of oil until...

Страница 14: ...If above test fails do not use receptacle until it is repaired or replaced d Press Reset button in for use RESET TEST RESET TEST Reset Button Test Button 120 Volt GFCI Receptacle 4 Plug in products 5...

Страница 15: ...t the engine can stabilize For MANUAL START A Turn the Engine Switch to ON B Grip the Starter Handle of the Engine loosely and pull it slowly several times to allow the gasoline to flow into the Engin...

Страница 16: ...er exceed the rated capacity for this Generator as serious damage to the Generator and or appliances tools and equipment could result from an overload Starting and running wattage requirements should...

Страница 17: ...r that only supplies the exact watts needed To Calculate Wattage Volts and amps can be multiplied together to get watts volts x amps watts To Calculate Additional Start Up Watts If They Are Not Listed...

Страница 18: ...gine in an emergency turn the Engine Switch off NOTICE Generator shut off under load may damage the Generator and attached equipment Stopping the Engine Under Normal Conditions 1 Before turning off th...

Страница 19: ...qualified technician service the equipment instead Cleaning Maintenance and Lubrication Note This maintenance schedule is intended solely as a general guide If performance decreases or if equipment o...

Страница 20: ...Remove the drain plug and if possible tilt the crankcase slightly to help drain the oil out Recycle used oil 5 Replace the drain plug and tighten it 6 Clean the top of the Dipstick and the area around...

Страница 21: ...de the spark plug can be damaged 5 Install the new spark plug or the cleaned spark plug into the engine Gasket style Finger tighten until the gasket contacts the cylinder head then about 1 2 2 3 turn...

Страница 22: ...uretor and carefully remove the Drain Bolt from the bottom of the Carburetor Bowl allowing the fuel to drain completely Replace the Drain Bolt after draining WARNING To prevent serious injury and fire...

Страница 23: ...ilter IGNITION SPARK RELATED 1 Power Switch at OFF position 2 Spark plug cap not connected securely 3 Spark plug electrode wet or dirty 4 Incorrect spark plug gap 5 Spark plug cap broken 6 Circuit bre...

Страница 24: ...y operate generator outside 2 Carbon monoxide sensor malfunction Sensor needs service Call 1 888 866 5797 as soon as possible Do not use the Generator until the sensor is working properly 3 Make sure...

Страница 25: ...er Plug in product and turn on 3 Turn off and unplug product Test GFCI receptacle If functioning properly reset GFCI plug in product and turn on 4 Have product repaired Product begins to operate abnor...

Страница 26: ...ASSEMBLY DIAGRAM IN THIS MANUAL AS A REFERENCE TOOL ONLY NEITHER THE MANUFACTURER OR DISTRIBUTOR MAKES ANY REPRESENTATION OR WARRANTY OF ANY KIND TO THE BUYER THAT HE OR SHE IS QUALIFIED TO MAKE ANY...

Страница 27: ...l Series 2 52 Wire Clip 1 53 Coil Subassembly Charge 1 54 Hex Socket Flange Face Bolt Small Series 2 55 Coil Ignition 1 56 Bolt 2 Part Description Qty 57 Clamp Charge Coil 1 58 Hex Socket Flange Face...

Страница 28: ...amp 1 141 Pipe Clamp 1 142 Pipe Clamp 1 143 Tube Fuel 1 144 Jacket Rubber 1 145 Cock Assy Fuel 1 146 Bolt 2 147 Crosspiece Subassembly 1 Part Description Qty 148 Bolt 1 149 Support Atr Cleaner 1 150 S...

Страница 29: ...64 65 66 67 67 68 68 69 70 71 72 71 74 75 76 78 77 73 80 82 83 84 79 81 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 107 108 105 106 109 110 111 112 113 114 115 116 117 119 118 120...

Страница 30: ...the exclusion or limitation of incidental or consequential damages so the above limitation of exclusion may not apply to you THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLI...

Страница 31: ...of components of the emissions control system and are covered by this two 2 year warranty For a full list of emissions control components covered by this warranty please see 40 CFR 1068 Appendix I 1...

Страница 32: ...26677 Agoura Road Calabasas CA 91302 1 888 866 5797...

Отзывы: