Page 5
For technical questions, please call 1-888-866-5797.
Item 56683
Over Information
1. If Torque is over 110% of full value, value will
be saved, LCD screen will show “OVER,” and
Wrench will vibrate continuously.
2. Press the On/Off Power Button to reset Wrench.
3. Over Information can be viewed by pressing
the Menu Button and selecting “Over Info.”
a. Counter: The number of times the Wrench
has gone over max torque (110%).
b. Torque: The max torque value ever reached.
c. Date: The date and time the max torque
was reached.
Note;
If the Wrench goes over 125% of the full
value, a reminder to recalibrate the Wrench will
appear after turning on the Wrench (until the
Wrench is recalibrated).
Note:
If the Wrench goes over 150% of the full
value, the LCD display will show “REPAIR” and
vibrate continuously. Press the On/Off Power
Button to shut down the Wrench. The Wrench
must be repaired only by a qualified technician.
Replacing Batteries
1. When battery level is low, LCD Screen will
display “Replace Battery” message.
2. Remove Cap (22) from Wrench. Remove old
batteries (if applicable) and dispose of properly.
3. Place 3 AA (1.5 V) batteries in correct polarity.
4. Replace cap before using the Wrench.
Maintenance and Servicing
Procedures not specifically explained in this manual
must be performed only by a qualified technician.
To prevent injury from
tool failure:
Do not use damaged equipment.
If abnormal noise or vibration occurs, have the
problem corrected before further use.
1.
BEFORE EACH USE,
inspect the general
condition of the tool. Check for:
• loose hardware,
• misalignment or binding of moving parts,
• cracked or broken parts, and
• any other condition that may affect its
safe operation.
2.
AFTER USE:
• Pull back Lock Ring and set Wrench to the
lowest torque setting.
• Wipe Wrench with a clean cloth. Do not
use liquid on the cloth or immerse wrench
in liquid.
3.
EVERY 6 MONTHS,
have the Torque Wrench
calibrated and serviced by a qualified
technician.