manualshive.com logo in svg
background image

Page 2

For technical questions, please call 1-888-866-5797.

Item 63313 

        

Before start-up, note the following:

The pump must be connected to a GFCI protected plug which has been installed according 
to regulations.  The plug must have a supply voltage of 120 VAC at 60 Hz.

CAUTION

This pump has been evaluated for use with water only.

WARNING

IMPORTANT!  For your own safety – 
before starting to run the pump, please have 
the following items checked by an expert:

1.  Risk of electric shock – This pump is supplied 

with a grounding conductor and grounding-type 
attachment plug.  To reduce the risk of electric shock, 
be certain that it is connected only to a properly 
grounded, grounding-type receptacle.

2.  Risk of electric shock – This pump has not been 

investigated for use in swimming pool areas.

3.  The electrical connections must be 

protected from moisture.

4.  If there is danger of flooding, the electrical 

connections must be taken to higher ground.

5.  Circulation of caustic fluids, as well as the circulation 

of abrasive materials, must be avoided at all costs.

6.  The pump must be protected from frost.

7.  The pump must be protected from running dry.

8.  Access by children should also be 

prevented with appropriate measures.

9.  To reduce the risk of electric shock, use only 

on portable self-contained fountains.

10. 

POSITION OF PUMP:

To avoid the possibility of the pump plug or 
receptacle getting wet, position pump to one 
side of a wall mounted receptacle to prevent 
water from dripping onto the receptacle or plug. 
The user should arrange a “drip loop” in the 
cord connecting the pump to a receptacle.

Pump

The “drip loop” is that part of the cord below the level 
of the receptacle, or the connector if an extension 
cord is used, to prevent water traveling along the 
cord and coming in contact with the receptacle.

11. 

To prevent death from electric shock, 
pump must be connected only to a GFCI 
protected outlet.

12.  Do not use an extension cord with this item.

13.  WARNING: The cord of this product contains 

lead and/or di (2-ethylhexyl) phthalate (DEHP), 
chemicals known to the State of California 
to cause cancer, and birth defects or other 
reproductive harm. Wash hands after handling.  
(California Health & Safety Code § 25249.5, 

et seq.

)

14.  People with pacemakers should consult their 

physician(s) before use.  Electromagnetic fields in 
close proximity to heart pacemaker could cause 
pacemaker interference or pacemaker failure.

15.  The warnings, precautions, and instructions 

discussed in this instruction manual cannot cover all 
possible conditions and situations that may occur.   
It must be understood by the operator that 
common sense and caution are factors 
which cannot be built into this product, but 
must be supplied by the operator.

Fluid Type

The Pump is designed for use with water with a maximum temperature of 77° F (25°C).  Do not use the pump 
for other fluids, especially not fuels, cleaning fluids, or other chemical products.

Содержание creekstone 63313

Страница 1: ...ture reference When unpacking make sure that the product is intact and undamaged If any parts are missing or broken please call 1 888 866 5797 as soon as possible Copyright 2016 by Harbor Freight Tools All rights reserved No portion of this manual or any artwork contained herein may be reproduced in any shape or form without the express written consent of Harbor Freight Tools Diagrams within this ...

Страница 2: ...ump plug or receptacle getting wet position pump to one side of a wall mounted receptacle to prevent water from dripping onto the receptacle or plug The user should arrange a drip loop in the cord connecting the pump to a receptacle Pump The drip loop is that part of the cord below the level of the receptacle or the connector if an extension cord is used to prevent water traveling along the cord a...

Страница 3: ... Pump will not function unless fully submerged Power Supply 1 The pump is equipped with a shock proof plug according to regulations The pump is designed to be connected to 120 VAC 60 Hz GFCI protected socket 2 Make sure that the socket is sufficiently secured and is in excellent condition 3 WARNING To prevent death from electric shock pump must be connected only to a GFCI protected outlet WARNING ...

Страница 4: ...f the basin if it is not suspended by the handle 2 Verify that the discharge pipe is properly connected 3 Verify that the electrical connection is 120 VAC 60 Hz 4 Verify that the electrical socket is GFCI protected and in good condition Test GFCI protected outlet before use 5 Verify that water and moisture cannot get near the power supply socket 6 Verify that the pump is installed so as to prevent...

Страница 5: ...3 Low line voltage 4 Check valve sold separately stuck or installed backwards 1 Remove Inlet Screen Clean out dirt and debris from Inlet Screen and impeller Then replace Inlet Screen 2 There must be at least 0 deep water for the Pump to operate properly 3 Consult an electrician 4 Remove and examine check valve Pump won t start or run 1 Check power connections and circuits fuses 2 Water level too l...

Страница 6: ...G OUT OF HIS OR HER REPAIRS TO THE ORIGINAL PRODUCT OR REPLACEMENT PARTS THERETO OR ARISING OUT OF HIS OR HER INSTALLATION OF REPLACEMENT PARTS THERETO Parts List Part Description Qty 1 Front Cover 1 2 Filter 1 3 Water Seating 1 4 Impeller Head 1 5 Impeller 1 6 Impeller Shaft 1 7 Sealing Ring 2 8 Shaft Cover 2 9 Suction Cup 4 10 Frame 1 11 Water Outlet 1 12 Pump Body 1 13 Motor 2 14 Grounded Termi...

Страница 7: ...Page 7 For technical questions please call 1 888 866 5797 Item 63313 Assembly Diagram 20 2 1 9 14 6 5 3 12 18 4 13 7 8 11 15 19 16 17 10 7 7A 4A 3A 2A 1A 6A 5A 8A ...

Страница 8: ...so the above limitation of exclusion may not apply to you THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS To take advantage of this warranty the product or part must be returned to us with transportation charges prepaid Proof of purchase date and an explanation of the complaint must accompany the merchandise If o...

Отзывы: