24
Lowes.com/harborbreeze
TROUBLESHOOTING
WARNINGt
Before beginning work, shut off the power supply to avoid electrical shock.
PROBLEM
POSSIBLE CAUSE
CORRECTIVE ACTION
The fan does not
move.
1. The reverse switch is not
engaged.
2. The power is off or the fuse is
blown.
3. There is a faulty wire connection.
4. The 9-wire plugs are not
connected properly.
1. Firmly push the reverse switch
to either the left or right.
2. Turn the power on or check the
fuse.
3. Turn the power off, loosen
the canopy, and check all
connections.
4. Check that the 9-wire plugs
in the switch housing are
connected properly.
The fan is noisy.
1. The blades are loose.
2. There is a cracked blade.
3. The wall control is not compatible
with the fan.
4. The break-in period has not
passed.
5. The outlet box is not secure.
6. The mounting bracket is not
secure.
1. Check and tighten all screws
that hold the fan blades to the
blade arms and the motor.
2. Replace the cracked blade.
3. Do not use a full range dimmer
switch to control the fan speed.
4. Run the fan continuously for 24
- 48 hours on medium or high
speed for a “break in” period.
5. Ensure the outlet box is secured
to the building structure.
6. Ensure the mounting bracket is
secured to the outlet box and
that the screws are tight.