23
4.11. Frost Precautions
During cold periods there is a risk of freezing overnight or when travelling on the road. Damage
caused by freezing is expensive to repair and IS NOT COVERED UNDER WARRANTY.
(H&S
Section 7)
Take the following precautions to avoid frost damage:
4.11.1.
To Anti-Freeze the Machine with an Anti-Freeze Tank
1.
The valves to control the antifreeze procedure are located as shown
2.
Shut the tank isolation valve
3.
Open the tank drain valve
4.
The handle for the 3-way ball valve should be in the vertical position.
5.
Put the jump jet valve into the “off” position
Anti-Freeze
Valve
Tank Isolation
Valve
Drain Valve
3-Way Ball Valve