background image

R

                                         

X H - K G 5 5 B

                     

 

R

                                                   

X H - K G 5 5 B

 

                                                                                                                                                                                                                                                                                           

5.0 

Explanation of  Programming

 

i.e.  proce ss  N o. 

F2

F2

F2

F2,

 ste p  N o

. L0

L0

L0

L0....

 

 
 
 
 
 
 

Diagram of Programming 

No 

a c t i o n  

s e t t i n g  

t e mp  

 

g r a d  

(℃

/min

 

i s o t h e r m  

t i m e

 

min

 

Process 

No.

F * 

Step No

  L * 

press RST

RST

RST

RST 

press PRG

PRG

PRG

PRG 

press 0

 0

 0

 0~

~9 

9  

press 

  

set parameters 

press 

  

set end program 

press RST

RST

RST

RST 

PPPP    

F0L0

F0L0

F0L0

F0L0     

F2L0

F2L0

F2L0

F2L0     

000.0

000.0

000.0

000.0    

0 8 0

0 8 0

0 8 0

0 8 0....0000    

000.0

000.0

000.0

000.0    

000.0

000.0

000.0

000.0    

    

    

    

0.0

0.0

0.0

0.0     

1111.5

.5

.5

.5     

0.0

0.0

0.0

0.0     

0.0

0.0

0.0

0.0     

    

    

    

    

0 0

0 0

0 0

0 0     

3 0

3 0

3 0

3 0     

0 0

0 0

0 0

0 0     

0 0

0 0

0 0

0 0     

    

 

enter F*L* 

enter F2 

enter data 

F2L1 

enter data 

F2L2,set 0 

end 

 

8  

   

6.0 

Diagram of  KG55B Output Connection

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

                          K G 5 5 B   F r o n t   P a n e l  

                                    Diagram 1 

9  

     

XH-KG55B

 

DYEING CONTROLLER

 

 

       

       

         

TEMP (℃)   *GRAD

(℃

/min)

*TIME 

(min)

*

 

                                           

 

                  HEAT          HOLD        CALL        RUN 

                                                   

 

                           
 

 

 

 

 

 

R

 

FOSHAN HANSUNG AUTOMATION Co., Ltd. 

  RUN 

STOP 

P R G 

R S T  

 

0

 

 

  hold ing  te mper atu re 

80℃  

fo r 30

 

                                                 

E N D  

 
 

u p -g rad ient    

1.5℃ /

min 

   

a mbie nt  te mper atu r e 

Содержание XH-KG55B

Страница 1: ...t interface to going to smaller and more intelligent direction And it is strong versatile fit for controlled temperature which is less than 150 i e washing mechanism and electric heater MAIN SPECIFICT...

Страница 2: ...radient and isotherm time 2 4 Temperature Control Method optimize self adaptive method 2 5 Temperature parameters setting range object temperature 030 0 150 0 gradient 0 2 9 9 min time of isothermic p...

Страница 3: ...r than 150 the controller calls and automatically stops 2 8 Power Range AC 180 250 V 50 60HZ Power consumption 3W 2 9 Dimension of Apparatus W 96 H 96 L 100 mm3 2 10 Dimension of Installation W 92 H 9...

Страница 4: ...thermic phase STOP and RST key can t be operated Up gradient rate and down gradient rate is set 00 in programming mode Quickly push STOP and RST key it can return to normal state Check error parameter...

Страница 5: ...ntroller runs but lights is on Output is ok AC contactor can t run or heated flex is burnt out Maintain external electric apparatus Increase temp slowly Power of heated flex is smaller Val ve Increase...

Страница 6: ...is old apparatus and bad probe we have to correct temperature The corrected temp value is used under 99 after the controller is in isotherm time 20mins It is right correction method that 6 bits standa...

Страница 7: ...If abnormal situation happens in operation cut off power for 5secs before the controller runs again or press RST 4 Operation of keys should be on for one second to avoid error 5 When programming set t...

Страница 8: ...L0 F2L0 F2L0 000 0 000 0 000 0 000 0 0 8 0 0 8 0 0 8 0 0 8 0 0 0 0 0 000 0 000 0 000 0 000 0 000 0 000 0 000 0 000 0 P 0 0 0 0 0 0 0 0 1 1 1 1 5 5 5 5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3...

Отзывы: