background image

R

                                         

X H - K G 5 5 B

                     

 

R

                                                   

X H - K G 5 5 B

 

                                                                                                                                                                                                                                                                                           

te mp era tur e  me asu re me nt r ange

: 000.0℃ ~ 153.0℃  

te mp era tur e con tro l  ran ge

: 030.0℃ ~ 150.0℃  

te mp era tur e con tro l a cc urac y

sta ble  er ror  

≤ ±

1.2

 

2.3 

P rogrammable Functions

 

     

  prog ra mmab le  p r ocess  N o

.:

(0

9 )

to ta l 10

 

          P

rogra mma ble   p roces s s tep s of  each  p r ocess  is  t en. 

         

         

E ach  s tep  is  b e s et o b jec t  te mp era tu re,  gradi ent  and   

          iso the r m  t i me. 

2.4 

Temperature Control Method

:

 

        optimize self-adaptive method

 

         
2.5 

Temperature p a rameters  s etting ra nge

 

     

o b jec t  te mper atu re

:(

030.0 

  150.0

) ℃  

     

g rad ien t

:(

0.2  

  9.9

) ℃

/ min

 

     

t i me o f  iso the r mic  phase

:(

00  

  9 9

min

 

2.6 

P rogramming Checkout  Func tions

 

      P res s

“ △ ”

ke y t o  check w heth er  se tt ing   

para mete rs  cor respon d  wi th  pa ra met ers  in  the    

proces s f lo wcha rt  or no t. 

2.7 

S afeke eping

 

1

)  

S uddenl y  powe r cu t o ff , a run ning  con tro l ler    

can con tin ual l y  run  in  r etr ie ving  the  old  proc e ss s tep    

data  af ter   powe r  is on  a gain. 

2  

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание XH-KG55B

Страница 1: ...t interface to going to smaller and more intelligent direction And it is strong versatile fit for controlled temperature which is less than 150 i e washing mechanism and electric heater MAIN SPECIFICT...

Страница 2: ...radient and isotherm time 2 4 Temperature Control Method optimize self adaptive method 2 5 Temperature parameters setting range object temperature 030 0 150 0 gradient 0 2 9 9 min time of isothermic p...

Страница 3: ...r than 150 the controller calls and automatically stops 2 8 Power Range AC 180 250 V 50 60HZ Power consumption 3W 2 9 Dimension of Apparatus W 96 H 96 L 100 mm3 2 10 Dimension of Installation W 92 H 9...

Страница 4: ...thermic phase STOP and RST key can t be operated Up gradient rate and down gradient rate is set 00 in programming mode Quickly push STOP and RST key it can return to normal state Check error parameter...

Страница 5: ...ntroller runs but lights is on Output is ok AC contactor can t run or heated flex is burnt out Maintain external electric apparatus Increase temp slowly Power of heated flex is smaller Val ve Increase...

Страница 6: ...is old apparatus and bad probe we have to correct temperature The corrected temp value is used under 99 after the controller is in isotherm time 20mins It is right correction method that 6 bits standa...

Страница 7: ...If abnormal situation happens in operation cut off power for 5secs before the controller runs again or press RST 4 Operation of keys should be on for one second to avoid error 5 When programming set t...

Страница 8: ...L0 F2L0 F2L0 000 0 000 0 000 0 000 0 0 8 0 0 8 0 0 8 0 0 8 0 0 0 0 0 000 0 000 0 000 0 000 0 000 0 000 0 000 0 000 0 P 0 0 0 0 0 0 0 0 1 1 1 1 5 5 5 5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3...

Отзывы: