![Hanskamp PowerSpray Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/hanskamp/powerspray/powerspray_installation-and-operating-instructions-manual_3692281013.webp)
13
-
22
Hanskamp AgroTech B.V. (the Netherlands)
www.hanskamp.nl/en
PowerSpray
EN
Vernevelsysteem, Zerstäubungssystem, liquids spraying system, vaporisateur de liquides
4.
FAQ
Frequent issue:
Possible cause:
Solution:
Pump is running for longer
than 30 seconds.
Leakage in fluid line.
End of line is not pushed in far
enough in the push
-
in coupling.
Line is not cutted straight, before
being pushed in the push
-
in
coupling
Air in the line.
Find the leak spot, and replace the line if necessary.
Push in the line in the push
-
in coupling, with more
force.
Cut the end of the line in a straight way, and again
push it in the push
-
in coupling.
Make sure the fluid level of the container is above the
end of the inlet line.
Bleed out the air of the line. For instructions, read
step 8 of chapter 3.4.
SprayUnit is not spraying/not
creating a mist, when Spray-
Unit is actuated
No fluid in the inlet line/ air in inlet
line.
SprayUnit is not connected the right
way.
The filter of the spray nozzle is clog-
ged.
Make sure the fluid level of the container is above the
end of the inlet line.
Bleed out the air of the line if necessary. For instructi-
ons, read step 8 of chapter 3.4.
Connect the SprayUnit to the feeding sytem, using
the corresponding manual. Consult your dealer for
more information.
Unscrew the spray nozzle and clean the inside of the
nozzle. It is advised to use compressed air, to blow
out any blockings in the nozzle.