 Doseersysteem

 

 

Note! The tube must be placed as perfect

 

as possible in the curve of the 

pump (fig. 21)

 

 

21.

 

Take the transparent cover (art.nr. 003

-

502

-

000) with the associated four long 

flange head screws (art.nr. 003

-

509

-

000). Position the cover so that it is right for 

the recess in the pump. Tighten the screws evenly until the lid is tight. Note: solid 
fixed! (fig. 22)

 

22.

 

Connect the motor of the MultiDos to the control board of the feeding station. 
First, make the control board voltage free, before connecting the motorcable

 

 

Attention! When connecting the motor to the control board, it is possible 
that light electric shocks can occur.

 

 

23.

 

Always mount the cover, so that dirt and dust can

t fall into the container.

 

24.

 

With one pump unit: mount a stainless steel blind plate on the other side of the 
container. Fasten the blind plate with the including socket screws (fig.24) (art.nr. 
003

-

545

-

000)

 

 

Maintenance:

 

Check the MultiDos on faults and wearing on a daily basis. Do this by means of a test 
on the output of de tubes and electric cables. Check periodical the quantity and cali-
brate if necessary.

 

When the HanskampQualityTube is worn by intensive use (leaking), 

replace it according described steps. A repair kit is available by Hanskamp. 
Also check the rollers and bearings for wear. Also these parts are  available 
as a repair kit by Hanskamp.

 

 

Attention! Replace the HanskampQualityTube every year, or after 
pumping 1000L of fluid.

 

 

Calibration:

 

For calibration: operate the motor manually till the liquid emerges from the 
nozzle.

 

 

Attention! During the first rotations you will not see anything hap-
pen, this is because the rotor gets fastened to the axel of the 

 

motor.

 

 

The MultiDos is calibrated by allowing the feeding computer to emit a pulse ten 
times. Then you measure the amount of dispended liquid, divide this by 10 and 
enter this value into the feeding computer. 
Repeat this procedure every month and also 
after changing the liquid. This is one of the 
possibilities for calibration. When the manual 

 

21

 

 

22

 

23

 

 

24

 

3545

 

Содержание MultiDos 035-000-000 Series

Страница 1: ...010 100 000 Date Nov 2017 Version 1 8 Translation of original instructions for use According to Annex 1 chapter 1 7 4 Machine guideline 2006 42 EG Doetinchem The Netherlands www hanskamp nl en Vloeist...

Страница 2: ...this manual The recommendations are meant to serve as guidelines All instructions pictures and specifications in this manual are based on the latest information that was available at the time of publi...

Страница 3: ...you to very easily dose the right quantity of liquids per day and per cow Smart fast and affordable MultiDos doses liquid propylene glycol like gravy on top of the feed chunks And cows love it The in...

Страница 4: ...operation and maintenance of your MultiDos You must make sure that you and anyone else who is going to operate maintain or work in the vicinity of the MultiDos knows all the related SAFETY information...

Страница 5: ...ectrical power supply for the MultiDos Make sure the electrical grounding of the electrical system and all parts of the MultiDos meet the local rules and regulations Replace any damaged electrical lin...

Страница 6: ...Switch off the electrical power supply by taking plug out of the power point and secure the plug before you clean or do maintenance on the Mul tiDos Wear protective clothing and safety goggles when yo...

Страница 7: ...iDos container with including 1 or 2 MultiDos pumps The container and or wall mount will be send in a box These boxes can be put on each other on a pallet The MultiDos system can also be send in a box...

Страница 8: ...e clip danger Attention When the container runs easily on the tube it should be fixed When the container can make multiple rotations it may impair the operation 5 Unscrew the 3 Socket screw with flang...

Страница 9: ...e feed through coupling as indicated in diagram 8 12 Take the pump remove the four long screws art no 003 509 000 and take the transparent cover of the pump housing art no 003 502 000 diag 9 13 Push t...

Страница 10: ...d through coupling art no 003 572 000 Mount this according to diagram 10 and 11 Attention When assembling of the hose clamps there is a small chance of clamp danger Attention Cut the hose off straight...

Страница 11: ...the HanskampQualityTube as much as possible in the shape of the casing Press this to the delivery hose as far back as possible in the stand pipe 20 Take the Rotor and turn this with the side of the co...

Страница 12: ...g socket screws fig 24 art nr 003 545 000 Maintenance Check the MultiDos on faults and wearing on a daily basis Do this by means of a test on the output of de tubes and electric cables Check periodica...

Страница 13: ...ntion Place the housing up to a maximum of 2 meters from the bottom of the storage tank The MultiDos can be mounted on two different ways 3a Attach to a wall Drill holes in the back of the MultiDos as...

Страница 14: ...rt no 001 886 000 as indicated in diagram 30 7 Steadily screw the pump housing with the accompanying screws art no 003 510 000 hand tight on the wall attachment Diag 29 8 Loosen the rotor of the pump...

Страница 15: ...mpQualityTube round and slide this over the left feed through coupling 11 Now slide the suction hose on the right feed through coupling 12 Repeat this with the delivery hose on the left hand side 13 T...

Страница 16: ...the rollers and bearings for wear Also these parts are available as a repair kit by Hanskamp We recommend to disconnect the rotor when the system is temporarily decommis sioned Replace the HanskampQua...

Страница 17: ...s again Type 16 enter Quit to exit the ID2000 user program The ID MR2000 tools menu 1 13 appears REMARK When the Scale factor has been changed all data from all ID2000 Main con trollers have to be era...

Страница 18: ...he processor 2 Maximize the intake speed of this feedstuff 3 Calibrate according to calibration test results 4 If the process computer cannot work with 1 100kg multiply all values by 10 Configuration...

Страница 19: ...tem due to vermin and so forth The warranty is not applicable to consequential damage that is not related to the machine itself All systems have been tested However in the event of faults Copyright an...

Страница 20: ...iquid runs out of the nozzle while the motor doesn t run False air between the pump and the nozzle Press the hose on the nozzle again check improve the sealing between the coupling and nozzle again mo...

Страница 21: ...ration pertains does meet the stipulations of the following directive s Machine Directive 2006 42 EC and completely or partially meets the following essential requirements and that the relevant techni...

Страница 22: ...de dosage Doseersysteem Annex 1 Information nozzle holders 003 518 000 003 518 000 Dill holes to mount the hose and nozzle insert the hose trough the center hole and mount the nozzle to the hose Then...

Страница 23: ...r Art Nr 035 321 000 Color 1 Black 2 Green 3 Blue 4 Red 5 Orange Motor 0 DC Motor black bald 1 DC SolidState5 2 AC with feedback 3 RIM time controlled 4 DC IM motor 5 AC time ctrld without fb 6 Air co...

Страница 24: ...24 30 Hanskamp AgroTech B V the Netherlands www hanskamp nl en MultiDos EN Dosing system Dosiersystem Systeme de dosage Doseersysteem Annex 3 Exploded view wall mount Remove Torque 8Nm Wall mount...

Страница 25: ...p AgroTech B V the Netherlands www hanskamp nl en MultiDos EN Dosing system Dosiersystem Systeme de dosage Doseersysteem Bijlage 4 Exploded view container with 2 pumps pump MultiDos 003 525 000 remove...

Страница 26: ...ltiDos EN Dosing system Dosiersystem Systeme de dosage Doseersysteem Bijlage 5 exploded view Rotor 003 524 000 only in combination with HanskampQualityTube 003 512 000 of 003 512 002 003 524 001 only...

Страница 27: ...environment It is the responsibility of the user to determine suitability of tubing formulation for each application 4 The HanskampQualityTube is not intended or recommended for medical applica tions...

Страница 28: ...ing machine dealer of the apparatus the MultiDos regarding HanskampQualityTube installa tion pump rollers guide rollers and supply channel maintenance and calibration Inspect the HanskampQualityTube f...

Страница 29: ...7x10 1 001 006 005 PVC hose 5 meter 7x10 1 001 947 000 Membrane grommet 1 003 510 000 Socket screw with flange M5x10 3 003 515 000 Countersunk Hexagon socket screw M6x20 3 003 518 000 Spray nozzle co...

Страница 30: ...Netherlands www hanskamp nl en MultiDos EN Dosing system Dosiersystem Systeme de dosage Doseersysteem Hanskamp AgroTech B V Broekstraat 17 7009 ZB Doetinchem The Netherlands Tel 31 0 314 393 797 Fax 3...

Отзывы: