SUCTION VAPOR CAPACITIES (TONS) 

(1 Ton=12,000  Btu/hr=3.517  kW=3042 kcal/hr)

‡ 2 psi= 0.14 bar g 

5 psi= 0.35 bar g 

10 psi= 0.69 bar g 

20 psi= 1.38 bar g

*Optional 25% or 50% reduced capacity ¾" (20 mm) plugs are available for unusually low loads if requested.

† –40

°

F (–40°C) and –20

°

F (–28.9°C) capacities are based on a two stage system.

For liquid overfeed evaporator suction between normal 2:1 to 5:1 rate, add 20% to the evaporator load or use the next larger port 
size to accommodate liquid volume accompanying the suction gas and to reduce impact velocity.

Conditions:

 

Capacities are based on the evaporator temperatures shown and +86

°

F (+30°C) liquid. R717: For each 10

°

F (5.6°C) 

lower liquid temperature, increase the above table capacity by 3%. R22: For each 10

°

F (5.6°C) lower liquid temperature, increase 

the above table capacity by 5%. To convert for R134a, multiply the R22 table values by 0.73 (accuracy within 8%). For other 
refrigerant capacities and suitability, contact the factory.

PORT 

SIZE 
(mm)

Cv

(Kv)

PRESSURE 

DROP 

ACROSS 

VALVE‡

R717

R22

EVAPORATING TEMPERATURE

EVAPORATING TEMPERATURE

–40ºF†

(–40ºC)

–20ºF†

(–28.9ºC)

0ºF

(–17.8ºC)

+20ºF

(–6.7ºC)

+40ºF

(+4.4ºC)

–40ºF†

(–40ºC)

–20ºF†

(–28.9ºC)

0ºF

(–17.8ºC)

+20ºF

(–6.7ºC)

+40ºF

(+4.4ºC)

¾"*

(20)

6.4

(5.5)

2 psi

4.7

6.4

7.4

9.5

12

2.1

2.8

2.8

3.6

4.4

5 psi

6.7

9.7

8.7

15

19

3.2

4.3

4.4

5.5

6.9

10 psi

13

15

20

26

5.8

6.0

7.7

9.6

20 psi

19

27

35

7.8

10

13

1"

(25)

11.7

(10)

2 psi

8.5

12

13

17

22

3.9

5.2

5.2

6.5

8.0

5 psi

12

18

16

27

34

5.8

7.9

8.0

10

13

10 psi

23

28

37

47

11

11

14

18

20 psi

36

49

64

14

19

24

1¼"
(32)

16.4

(14)

2 psi

12

16

19

24

31

5.4

7.2

7.2

9.1

11.3

5 psi

17

25

22

38

48

8.1

11

11

14

18

10 psi

32

39

52

66

15

15

20

25

20 psi

50

69

90

20

26

34

1½"
(40)

35

(30)

2 psi

25

35

40

52

65

12

15

15

19

24

5 psi

37

53

48

81

102

17

24

24

30

38

10 psi

69

84

111

141

31

33

42

53

20 psi

106

147

193

43

56

72

2"

(50)

47

(40)

2 psi

34

47

54

70

87

16

21

21

26

32

5 psi

49

71

64

108

137

23

32

32

41

51

10 psi

92

113

149

190

42

44

56

71

20 psi

143

198

259

57

76

96

2½"
(65)

77

(66)

2 psi

56

77

89

114

143

25

34

34

43

53

5 psi

81

116

105

177

224

38

52

53

67

83

10 psi

151

185

243

311

69

72

92

116

20 psi

234

324

424

94

124

158

3"

(80)

104

(89)

2 psi

76

104

120

154

193

34

46

46

58

71

5 psi

109

157

141

239

303

51

70

71

90

112

10 psi

204

250

329

420

93

97

125

156

20 psi

316

438

572

127

167

213

4"

(100)

166

(142)

2 psi

121

166

191

246

309

55

73

73

92

114

5 psi

174

251

226

382

483

82

112

114

144

179

10 psi

325

398

525

671

149

155

199

249

20 psi

505

699

913

203

267

340

5"

(125)

242

(207)

2 psi

176

242

278

358

450

80

107

107

135

166

5 psi

254

365

329

557

704

120

163

166

210

261

10 psi

474

581

765

978

218

226

290

363

20 psi

736

1019

1331

295

390

496

6"

(150)

413

(354)

2 psi

300

412

475

611

768

136

182

183

230

283

5 psi

434

624

562

950

1202

204

278

282

358

446

10 psi

809

991

1305

1669

371

386

496

620

20 psi

1256

1739

2272

504

665

847

4

R429d
AUG 2015

Содержание HA4A series

Страница 1: ...petrochemical plants pharmaceutical plants supermarkets and many others APPLICATIONS Evaporator Pressure Control Defrost Pressure Control Condensing Pressure Regulation Receiver Pressure Control Hot G...

Страница 2: ...h a conduit fitting is standard Optional DIN Plug Coils are for grounded cord connections and include the necessary DIN plug socket with gasket Hansen long life Beacon Pilot Lights are available They...

Страница 3: ...inlet and outlet pressure See page 8 HA4AK RESEATING RELIEF REGULATOR Used for defrost high to low side relief or nonatmosphere relief to other parts of the system This control opens when system upstr...

Страница 4: ...7 9 6 20 psi 19 27 35 7 8 10 13 1 25 11 7 10 2 psi 8 5 12 13 17 22 3 9 5 2 5 2 6 5 8 0 5 psi 12 18 16 27 34 5 8 7 9 8 0 10 13 10 psi 23 28 37 47 11 11 14 18 20 psi 36 49 64 14 19 24 1 32 16 4 14 2 psi...

Страница 5: ...324 230 2 65 553 377 3 80 733 505 PORT SIZE mm OIL P 30 psi 2 bar g 20 48 1 25 87 1 32 122 1 40 260 2 50 350 2 65 574 3 80 775 REFRIG APPLICATION PORT SIZE mm 20 1 25 1 32 1 40 2 50 2 65 R717 Hot Gas...

Страница 6: ...1 or Range V 20 to 130 psig 0 67 to 9 bar g Part 75 1249 Catalog M3P RESEATING RELIEF Opens wide when pressure exceeds pressure setting and repeatedly reseats after operation Defrost relief or high to...

Страница 7: ...lable on order from to 6 20mm to 150mm Each AR1 and AR3 includes flange gaskets nuts and bolts and a plugged FPT outlet pressure access port The access port is for connecting outlet or differential co...

Страница 8: ...ressure reading A pressure gauge downstream is also required With the control module range spring force at the minimum control module stem turned fully counterclockwise at this point pressure differen...

Страница 9: ...direction of arrow ADJUSTMENT With solenoid control module de energized follow adjustment procedures for the HA4A Standard Regulator See page 8 HA4AS REGULATOR WITH ELECTRIC SHUT OFF OPERATION When th...

Страница 10: ...Tighten the locking ring after the final adjustment has been made Range 40 F to 30 F 40 C to 0 C or 15 F to 75 F 10 C to 25 C HA4AJ ELECTRONICALLY CONTROLLED REGULATOR OPERATION The controller receive...

Страница 11: ...or counterclockwise to lower the inlet pressure setting When the desired refrigerant pressure setting is achieved tighten the adjustment locking nut A final adjustment should be made after the system...

Страница 12: ...H2 H3 H4 L L1 L2 L3 L4 M W FPT SW WN ODS 1 1 20 25 32 3 09 78 6 77 172 3 75 95 4 63 117 8 20 208 8 94 227 6 19 157 2 38 60 4 07 103 7 20 183 3 70 94 4 50 114 1 2 40 50 2 87 73 8 84 225 4 90 124 5 72...

Страница 13: ...SERIES AND PARALLEL ARRANGEMENT AD SI solenoid SII P pressure pilots FOR SERIES ARRANGEMENT AS SI solenoid SII pressure pilot 5 AND 6 PILOT PIPING TOP VIEW WELD END DIMENSIONS mm T A DIA See page 8 SI...

Страница 14: ...1 8 Seal Cap O ring 1 70 0011 Diaphragm Gasket Kit M3O 75 1108 Above kit consists of LDSKUDP RZHU DVNHW WKLFN 8SSHU DVNHW WKLQ ROORZHU 2 ULQJ LEHU DVKHU RZHU 6WHP 2 ULQJ JUHHQ GRW 8SSHU 6WHP 2 ULQJ 6H...

Страница 15: ...Piston Kit FRQVLVWV RI 75 1019 3LVWRQ 3LVWRQ 6HDO GDSWHU DVNHW ODQJH DVNHW V Port Seal Kit 3 4 75 1020 V Port Seal Kit 1 75 1021 V Port Seal Kit 1 1 4 75 1022 Above kits consist of D 9 3RUW 6HDW E 9...

Страница 16: ...XJK E 6HDO DS LW ITEM DESCRIPTION QTY PART NO Gasket Kit 1 1 2 2 75 1039 Gasket Kit 2 1 2 75 1040 Gasket Kit 3 75 1041 Gasket Kit 4 75 1042 Above kits consist of D GDSWHU DVNHW E GDSWHU DVNHW F GDSWHU...

Страница 17: ...PARTS LIST 1 THROUGH 4 40mm THROUGH 100mm 14 17 15 16 13 12 11 10 9 20 18 3 4 5 6 23 22 8 7 25 21 24 1 2 19 SII P AR1 SI AR3 17 R429d AUG 2015...

Страница 18: ...75 1112 V Port Seat Kit 6 75 1113 Above kits consist of D 9 3RUW 6HDW E 9 3RUW 6HDW GDSWHU 2 ULQJ QQHU GDSWHU 2 ULQJ 2XWHU 6HDW 6HDO 2 ULQJ 6HDW 6FUHZ ORVLQJ 6SULQJ 6HDW 5LQJ 0DQXDO 2SHQLQJ 6WHP 6HDO...

Страница 19: ...any refrigerant which may still remain in the valve If disc piston is difficult to remove insert a 20 threaded screw 3 8 16 for 5 6 valves into center of piston and lift straight up Inspect piston an...

Страница 20: ...ype HA4W with integral butt weld end only 1 is standard 2 bolt flange design 4 bolt flange style available upon request to field replace 1 R S 25 and 50 Reduced Capacity Plugs are also available Weld...

Отзывы: