Space required according to the appliance
dimensions
A:
1880 mm
B:
595 mm
C:
300 mm
D: 630 mm
E:
1179 mm
F:
100 mm
G:
100 mm
H: 135°
I:
1000 mm
– To prevent the formation of a flammable
gas-air mixture in the event of a leakage
in the refrigeration circuit, the installation
space must have a minimum size of 1 m
3
per 8 g of refrigerant in compliance with
the EN 378 standard. The amount of re-
frigerant contained in your appliance can
be found on the type plate and on the data
sheet at the end of this user manual.
– The appliance must only be placed on a
level and firm surface. The surface must be
strong enough to support the appliance’s
weight when fully laden.
– Suitable locations are dry, well-ventilated
areas that are cool if possible.
– Unsuitable locations are ones with direct
sunlight or which are directly next to an
oven, hob or radiator.
– The following minimum distances must be
maintained:
– from electrical hobs
3 cm
– from oil and coal burning stoves 30cm
– from other cooling appliances
2 cm
– from washing machines/
dishwashers
2 cm
– If you would like to reduce these distances,
you can fit an insulation plate between the
appliances.
– If underfloor heating is installed at the set-
up location, place the cooling appliance on
an insulation plate made from solid mate-
rial.
Space requirement diagram (when the door is open and when the door is closed)
Start-up
Page GB-22