4
English
Assembly
(see page 35)
Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The hot and cold supplies must be of equal pressures.
Installation Instructions
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be observed.
• During initial start-up and after servicing, air in the
fittings can cause noise. After switching the jet on and
off about 15 times, the noise will stop.
Technical Data
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,1 - 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 60°C
Thermal disinfection:
70°C / 4 min
The product is exclusively designed for drinking water!
Symbol description
Do not use silicone containing acetic acid!
Adjustment
(see page 40)
To adjust the hot water limiter. Using a hot water limiter in
combination with a continuous flow water heater is not
recommended.
Maintenance
(see page 45)
The check valves must be checked regularly according to
EN 806-5 in accordance with national or regional
regulations (at least once a year).
Dimensions
(see page 41)
Flow diagram
(see page 41)
Spare parts
(see page 42)
XXX = Colors
000 = Chrome Plated
670 = Matt Black
800 = Stainless Steel Optic
Special accessories
(order as an extra)
extension #43333000 (see page 39)
Cleaning
(see page 44)
Operation
(see page 46)
• Hansgrohe recommends not to use as drinking water
the first half liter of water drawn in the morning or
after a prolonged period of non-use.
• Minor leaking may occur briefly at the spout when
opening the fitting via the lever.
• Use the lever to open the tap and set the desired
temperature. The water flow can be paused by
pressing the Select button on the face side of the
spout. When the tap is not used for a longer period of
time, f.e. when retiring at night or leaving the house, it
must be closed completely by means of the lever.
Fault
Cause
Remedy
Insufficient water
- Aerator calcified, dirty
- Clean aerator, replace as necessary
Mixer stiff
- Cartridge defective, calcified
- Exchange cartridge
Mixer dripping
- Cartridge defective
- Exchange cartridge
Water escaping in area of swivel
spout
- O-ring defective
- Exchange O-ring
Water escaping at the threaded base - connection hoses not completely
screwed into basic body
- Tighten connection hoses by hand
- O-ring at the connection hose
defective.
- Exchange O-ring
Hot water temperature too low
- Hot water limiter incorrectly set
- Set hot water limiter
Содержание Zesis M33 150 2jet 74821 Series
Страница 35: ...35 max 35 mm max 60 mm 3 Nm SW 19 mm 4 Nm SW 9 mm 1b 1a 2 3 4 5...
Страница 36: ...36 1 2 3 11 9 10 SW 17 mm SW 22 mm SW 22 mm SW 19 mm 4 Nm 97206000 450 mm SW 17 mm 8 Nm 22 mm 1 2 6 7 8...
Страница 37: ...37 14 1 2 12 13 15a max 30 mm max 30 mm...
Страница 38: ...38 max 20 15b max 20 15c F12 43333000 max 30 mm 15d max 20...
Страница 39: ...39 16 17 F12 43333000 max 100 mm 2 min 1 Nm...
Страница 40: ...0 3 MPa 0 3 0 3 60 C 10 C 40 1 2 SW 2 5 mm 4x 1 2 SW 2 5 mm 3 5 Nm 1 2 5 6 4 3 36 C 38 C 43 C 60 C 55 C 50 C...
Страница 45: ...45 1 2 1 2...
Страница 46: ...46 1 2 Zesis M33 150 2jet 74821XXX Zesis M33 160 2jet 74823XXX...
Страница 47: ...47...