Fault
Cause
Remedy
Insufficient water
-
Supply pressure inadequate
-
Check water pressure (If a pump
has been installed check to see if
the pump is working).
-
Regulator filter dirty
-
Clean filter in front of the mixer and
on the MTC-thermo cartridge
-
Shower filter seal dirty
-
Clean filter seal between shower
and hose
Crossflow, hot water being forced
into cold water pipe, or vice versa,
when mixer is closed
-
Backflow preventers dirty or leaking
-
Clean backflow preventers, ex-
change if necessary
Spout temperature does not cor-
respond with temperature set
-
Thermostat has not been adjusted
-
Adjust thermostat (see page 6)
-
Hot water temperature too low
-
Increase hot water temperature to
42 ºC to 65 ºC (see page 7)
Temperature regulation not possible
-
thermo cartridge calcified
-
Exchange thermo cartridge
Shower or spout dripping
-
Dirt or sedimentation on valve seat,
shut-off unit damaged
-
Clean or exchange shut-off unit
Instantaneous heater didn't work with
thermostat
-
Filters are dirty
-
Clean the filter / exchange filter
-
check valve hasn't moved back
-
Exchange check valves
-
Flow limiter in handshower isn’t
removed
-
Remove flow limiter
Test certificate
(see page 24)
Содержание Talis Puro 13148000
Страница 22: ...22 SW 24 mm X X 36 mm X 36 5 1 3b 2 4 3a 1 2 1 2 Silicone max 39 mm max 5 mm 1 2 36 mm ...
Страница 23: ...23 6 7 8 SW 30 mm 17 Nm ...
Страница 25: ...25 z B 42 C for example 42 C 1 2 3 5 6 4 1 2 1 2 2 1 SW 3 mm 2 Nm SW 3 mm ...
Страница 26: ...26 1 4 3 5 SW 3 mm 2 Nm 6 2 SW 3 mm 10 l min ...