Assembly see page 33
Cleaning
(see page 37) and enclosed brochure
Operation
(see page 36)
Maintenance
(see page 39)
• The non return valves must be checked regularly according to DIN
EN 1717 in accordance with national or regional regulations (at
least once a year).
• To guarantee the smooth running of the thermostat, it is necessary
from time to time to turn the thermostat from total hot to total cold.
Special accessories order as an extra
(see page 38)
corner fitting set
#27999000
Spare parts
(see page 38)
Flow diagram
(see page 31)
Hand shower
overhead shower (Rain)
overhead shower (Rainflow)
Dimensions
(see page 31)
Do not use silicone containing acetic acid!
Safety Function
(see page 35)
The desired maximum temperature for example max. 42º C can be pre-
set thanks to the safety function.
Adjustment
(see page 34)
After the installation, the output temperature of the thermostat must be
checked. A correction is necessary if the temperature measured at the
output differs from the temperature set on the thermostat.
Symbol description
Safety Notes
Gloves should be worn during installation to prevent crushing and cutting
injuries.
The hot and cold supplies must be of equal pressures.
The shower system may only be used for bathing, hygienic and body cleansing
purposes.
Children as well as adults with physical, mental and/or sensoric impairments
must not use this shower system without proper supervision. Persons under the
influence of alcohol or drugs are prohibited from using this shower system.
Do not allow the streams of the shower touch sensitive body parts (such as your
eyes). An adequate distance must be kept between the shower and you.
The product may not be used as a holding handle. A separate handle must be
installed.
Installation Instructions
• Prior to installation, inspect the product for transport damages. After it has been
installed, no transport or surface damage will be honoured.
• The fitting must be installed, flushed and tested after the valid norms.
• Where the contractor mounts the product, he should ensure that the entire area
of the wall to which the mounting plate is to be fitted, is flat (no projecting joints
or tiles sticking out), that the structure of the wall is suitable for the installation
of the product and has no weak points. The enclosed screws and dowels are
only suitable for concrete. For another wall constructions the manufacturer’s
indications of the dowel manufacturer have to be taken into account.
• The installation dimensions stated in these installation instructions are ideal
for people of approximately 1800 mm in body height. The dimensions can
be altered if required. In this case, pay attention to the fact that a change of
installation height will also change the minimum height, and that the altered
mounting dimensions must be taken into consideration.
• The panel is movable 200 mm downward. The stated dimensions refer to the
highest position of the panel.
• The premounted filter insert must be used to ensure a normal flow of the shower
and to prevent dirt from entering through the pipes. Dirt entering can affect the
function and/or lead to damages to the shower. Hansgrohe will not be held
liable for this type of damage.
Technical Data
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,22 - 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 80°C
Recommended hot water temp.:
65°C
Thermal disinfection:
max. 70°C / 4 min
Anti-pollution function
The product is exclusively designed for drinking water!
English
4
Содержание Raindance Lift
Страница 32: ...32 G 265 420 260 625 1800 2138 330 365...
Страница 34: ...34 7 8 1 2 SW 10 mm 9 1 2 3 1 2 1 2 1 2...
Страница 35: ...35 2 SW 3 mm 1 z B 42 C for example 42 C 1 2 3 4 5 6 7 8 9 10 11 SW 3 mm 2 Nm 1 2 1 2 12...
Страница 36: ...40 C 200 mm 40 100 N 36...
Страница 37: ...37 2 3 1 4 5 6 2 3 1 1 2 SW 5 mm 3 SW 5 mm 2 Nm...
Страница 39: ...2 SW 10 mm 8 1 2 SW 10 mm 7 2 SW 24 mm 5 6 SW 24 mm 3 4 1 1 3 4 39...
Страница 43: ...3 6 mm...