background image

75

Thermostatic Adjustment 

Temperature Limitation 

The temperature is limited by the safety stop to 40°C. If 
a higher temperature is required, it is possible to over ride 
the safety stop by depressing the safety button.

NB.

  It  is  recommended  that  for 

private  domestic 

use

 the maximum mixed water temperature be set at the 

following factory set values:

Shower Mixer 43°C
Bath/Shower 43°C

Temperatures  can  be  set  by  following  the  procedures 
on  pages  62  and  63.

 

This  ensures  that  after  correct 

installation the outlet temperature of the water can never 
exceed 43°C.

To guarantee a smooth running of the thermostatic element, 
it is necessary from time to time to turn the thermostat from 
total hot to total cold. The thermostatic mixer valve should 
be  checked  annually  by  a  qualified  person  to  ensure 
correct operation.

The  mixer  is  fitted  with  check  valves  (pages  68  and 
69 pos. 94074000) and filters (pages 68 and 69 pos 
94282000). If the water flow drops the filters need to be 
cleaned. For that purpose please follow the steps 1 - 12 
on pages 64 and 65.

Calibrating Thermostat 

If  the  temperature  reading  is  different  to  the  showering 
temperature, follow the steps 1 - 3 on page 62. 

Technical Hotline 

E-mail

0 870  7701975 

[email protected]

Содержание Ecostat S

Страница 1: ...22 ZH 24 RU 26 HU Haszn lati tmutat Szerel si tmutat 28 FI K ytt ohje Asennusohje 30 SV Bruksanvisning Monteringsanvisning 32 LT Vartotojo instrukcija Montavimo instrukcijos 34 HR Upute za uporabu Upu...

Страница 2: ...e 1 6 MPa 1 MPa 10 bar 147 PSI Hot water temperature max 80 C Recommended hot water temp max 65 C Thermal disinfection max 70 C 4 min Safety against backflow The product is exclusively designed for dr...

Страница 3: ...e set Thermostat has not been adjusted Adjust thermostat Hot water temperature too low Increase hot water temperature to 42 C to 65 C Temperature regulation not possible Temperature regulator dirty or...

Страница 4: ...60 Montage 3 2 4 1 2 1 2 1 2 6 5 X X 11 1 2 mm...

Страница 5: ...61 Montage 9 PuraVida 15775XXX 8 7 1 2 3 Nr 1047 6220 Ar ma tur en fet t Gr ea se S W 2 m m 4 N m SW 3 mm 4 Nm 11 10...

Страница 6: ...62 Safety Function Justierung 1 2 S W 3 m m 1 2 3...

Страница 7: ...63 Safety Function 2 1 5 6 S W 3 m m 4 N m 7 8 z B 42 C for example 42 C 1 2 3 4 SW 2 mm 4 Nm...

Страница 8: ...64 Wartung SW 4 mm 1 2 2 3 4 5 6 SW 24 mm 1 2 3 1 S W 3 m m SW 2 mm 4...

Страница 9: ...65 Wartung SW 4 mm 5 Nm 7 8 9 10 11 12 SW 24 mm 15 Nm Nr 1047 6220 Ar ma tur en fet t Gr ea se S W 3 m m 4 N m SW 2 mm 4 Nm 1 2 3 4...

Страница 10: ...eti avage atv rt otvoriti pne hape schlie en ferm close chiudere cerrar sluiten lukke fechar zamkn zav t uzavrie bez r s sulkeminen st nga u daryti Zatvaranje kapatmak nchide zapreti sulgege aizv rt z...

Страница 11: ...67 Ecostat E 15700000 Ecostat S 15701000 PuraVida15775XXX Metris 31572000 Ma e Durchflussdiagramm...

Страница 12: ...m 95037000 96525000 M5x20 98133000 16x2 96451000 96435000 95508000 48x3 98371000 29x3 97669000 38391000 Ecostat S 15701000 97747000 13595000 25 mm 94073000 96551000 96439000 94282000 94074000 96449000...

Страница 13: ...96446000 94009000 96454000 M5x55 98793000 145 mm 95037000 96525000 M5x20 98133000 16x2 96451000 96435000 95508000 48x3 98371000 29x3 97669000 11791XXX 95356XXX 94073000 95904000 96439000 94282000 9407...

Страница 14: ...plastic bags carefully Keep children well away from the work area Check for hidden pipes and cables in the wall before drilling holes The unit must be mounted on a finished waterproofed wall surface u...

Страница 15: ...allowable temperature tolerances inherent in thermo static mixing valves and temperature losses in metal baths It is not a safe bathing temperature for adults or children The British Burns Association...

Страница 16: ...72 KEY Isolating valve Reducing valve Mixer Valve Pump Gas Combination Boiler multi point Unvented System pressure balanced Pumped System...

Страница 17: ...priate at commissioning to carry out some simple checks and tests on each mixing valve to provide a performance reference point for future in service tests Procedure 1 Check that a the designation of...

Страница 18: ...ce of any other instruction or guidance on the means of determining the appropriate frequency of in service testing the following procedure may be used 1 6 to 8 weeks after commissioning carry out the...

Страница 19: ...perature of the water can never exceed 43 C To guarantee a smooth running of the thermostatic element it is necessary from time to time to turn the thermostat from total hot to total cold The thermost...

Страница 20: ...76 Hansgrohe Auestra e 5 9 D 77761 Schiltach Telefon 49 0 78 36 51 1282 Telefax 49 0 7836 511440 E Mail info hansgrohe com Internet www hansgrohe com 06 2013 9 08420 08...

Отзывы: