2
Assembly see page 4
Fault
Cause
Remedy
Mixer stiff
-
Cartridge defective, calcified
-
Exchange cartridge
Mixer dripping
-
Cartridge defective
-
Exchange cartridge
Diverter not operating
-
Residue
-
Clean converter / grease O-rings
-
Water pressure to low
-
Increase water pressure
-
Diverter defective
-
Exchange diverter
Hot water temperature too low, no
cold water. Instantaneous water
heater starts up when cold water is
selected.
-
Hot water limiter incorrectly set
-
Set hot water limiter
-
Crossflow
-
Exchange cartridge
Cleaning
see enclosed brochure
Spare parts
(see page 7)
Operation
(see page 8)
Dimensions
(see page 6)
Adjustment
(see page 5)
To adjust the hot water limiter. Using a hot
water limiter in combination with a continu-
ous flow water heater is not recommended.
Do not use silicone containing acetic acid!
Symbol description
Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The product may only be used for bathing, hygienic
and body cleaning purposes.
The hot and cold supplies must be of equal pres-
sures.
Installation Instructions
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be observed.
Technical Data
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,1 - 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 70°C
Recommended hot water temp.:
65°C
Thermal disinfection:
max. 70°C / 4 min
Safety against backflow
The product is exclusively designed for drinking water!
English
Flow diagram
(see page 6)
Rate of flow by 0,3 MPa:
Tub outlet
Shower outlet