Technical Information
Recommended water pressure
15 - 75 PSI
Max. water pressure
145 PSI
Recommended hot water temp. 120° - 140° F*
Max. hot water temp
176°F*
Flow rate - showerhead
2.0 GPM max.
Flow rate - handshower
1.85 GPM max.
Flow rate - tub filler
5.3 GPM@ 44 PSI
* Please know and follow all applicable local plumb-
ing codes when setting the temperature on the water
heater.
Installation Considerations
• For best results, Hansgrohe recommends that
this unit be installed by a licensed, professional
plumber.
• Please read over these instructions thoroughly
before beginning installation. Make sure that
you have all tools and supplies needed to
complete the installation.
• The installation dimensions shown in this
installation instruction are ideal for people of
approximately 6' in height. The dimensions can
be changed if required. In this case, the minimum
ceiling height of 86⅜" from the standing surface,
and all other measurements, must be changed.
• The installer must ensure that the entire area of
the wall to which the mounting plate is to be
mounted, is flat (no protruding grout joints or
tiles). He should also make sure that the wall is
strong enough to support the showerpipe.
• The enclosed screws and anchors are suitable for
a solid surface wall. If installing in a fiberglass or
acrylic shower unit, install header boards at the
mounting points.
• This showerpipe requires showerpipe rough
16181181(not included).
• This showerpipe is for use with shower heads
rated at 1.7 GPM (6.4 l/min) or higher.
• To prevent scald injury, the maximum output
temperature of the shower valve must be no
higher than 120°F. In Massachusetts, the
maximum output temperature can be no higher
than 112° F.
• Keep this booklet and the receipt (or other proof
of date and place of purchase) for this product in
a safe place. The receipt is required should it be
necessary to request warranty parts.
This unit meets or exceeds the
following:
• ASME A112.18.1 / CSA B125.1
• Listed by IAPMO for use in the
US and Canada
Содержание Croma Showerpipe
Страница 19: ...19 User Instructions Instructions de service Manejo on ouvert abierto 1 1 2 2...
Страница 20: ...20 User Instructions Instructions de service Manejo function lever levier palanca 104 F 1 2...
Страница 21: ...21 Cleaning Nettoyage Limpieza scale remover d tartrant desincrustante 1 2 3 1 2...
Страница 22: ...22 Cleaning Nettoyage Limpieza Scale Remover 1 min scale remover d tartrant desincrustante 1 2 3 1 2...
Страница 23: ...23 Check Valve Maintenance Entretien Mantenimiento 3 mm 2 3 4 30 mm 10 mm 1 2 3 1 1 2 3 4...