Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
Children as well as adults with physical, mental and/or
sensoric impairments must not use this shower system
without proper supervision. Persons under the influence
of alcohol or drugs are prohibited from using this shower
system.
The shower system may only be used for bathing, hygienic
and body cleansing purposes.
Do not allow the streams of the shower touch sensitive
body parts (such as your eyes). An adequate distance
must be kept between the shower and you.
Assembly
(see page 62)
Important!
The fitting must be installed, flushed and
tested after the valid norms.
Important!
Do not use silicone containing acetic acid!
Adjustment
(see page 65)
Correction is necessary if the temperature measured at the
take off point differs from the temperature set on the scale.
To adjust temperature proceed as follows: Turn the setting
knob until water at a temperature of 38º C comes out of
the outlet. Loosen screw of setting knob. Remove setting
knob and turn to the 38º C position. Attach setting knob
again and tighten the screw.
Operation
(see page 63)
Temperature limitation
The temperature is limited by the safety check to 38º C
(100º F). If a higher temperature is required, it is possible to
override the safety stop by depressing the safety button.
Safety Function
(see page 64)
The desired maximum temperature for example max. 42º
C can be pre-set thanks to the safety function.
Technical Data
(see page 2)
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,1 – 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 80°C
Recommended hot water temp.:
65°C
Rate of flow by 0,3 MPa:
approx. 20 l/min
Maintenance
(see page 66)
There is no special maintenance for thermostats.
However, once a year the function of the non-return-valve
(97350000 / 97980000) has to be checked. At this
time, please also check the filter (6.1) situated on the
MTC-thermoelement (98282000). After assembling the
MTC-thermoelement, it is necessary to check the water
temperature at the take off point as described under the
headline „adjustment“. Before the adjustment, please
check, if the warm water supply is activated and the
maximum temperature of the warm water is available at
the take off point.
To guarantee the smooth running of the thermostat, it is
necessary from time to time to turn the thermostat from
total hot to total cold.
Spare parts
(see page 67)
Cleaning
(see page 68)
English
Содержание AXOR Urquiola 11422000
Страница 1: ...Montageanleitung Urquiola 11422000...
Страница 27: ...27 42 C 65 C 180 180...
Страница 29: ...29 42 65 180...
Страница 45: ...45 temperatura del agua demasiado baja no hay 42 C 65 C 180 180...
Страница 47: ...47 42 65 180 180...
Страница 59: ...59 42 C 65 C 180 180...
Страница 64: ...64 1 2 3 4 Safety Function...