10
Justify the handle
Tools required:
Thermometer
3 mm Allen wrench
Turn the valve on. Place the thermometer in the
water stream.
Turn the temperature control knob until the output
water is 100°F.
Turn the water off.
Use a 3 mm Allen wrench to loosen the handle set
screw. Remove the handle from the valve (1).
Hold the handle lever in one hand. With the
other hand, turn the temperature control knob
approximately ½ turn clockwise (2a). Then,
without pressing inward on it
, turn it counter-
clockwise until it is positioned vertically and hits
the safety stop (2b).
Install the handle (3). Tighten the screw.
All models:
Install the carrier plate and gasket
with the carrier plate screws.
Press the escutcheon firmly over the carrier plate.
The strips of Duotec will interlock, producing a
very firm hold.
Install the handle. Tighten the handle screw with
a 3 mm Allen wrench. The handle screw must
engage the slot milled into the brass on the bottom
of the cartridge.
Set the high temperature limit stop (optional) – see
page 11.
Justify the handle.
2
a
b