Gloves should be worn during installation to prevent crushing and cutting
injuries.
The product may only be used for bathing, hygienic and body cleaning
purposes.
The arm of the shower head is intended only to hold the shower head. Do not
load it down with other objects!
Children as well as adults with physical, mental and/or sensoric impairments
must not use this product without proper supervision. Persons under the
influence of alcohol or drugs are prohibited from using this product.
Do not allow the streams of the shower touch sensitive body parts (such as your
eyes). An adequate distance must be kept between the shower and you.
The product may not be used as a holding handle. A separate handle must be
installed.
The hot and cold supplies must be of equal pressures.
Installation Instructions
• Prior to installation, inspect the product for transport damages. After it has been
installed, no transport or surface damage will be honoured.
• The pipes and the fixture must be installed, flushed and tested as per the
applicable standards.
• The plumbing codes applicable in the respective countries must be observed.
• The installation dimensions stated in these installation instructions are ideal for
people of approximately 1800 mm in body height. The dimensions can be
altered if required. In this case, pay attention to the fact that a change of
installation height will also change the minimum height, and that the altered
mounting dimensions must be taken into consideration.
• During installation of the product by qualified trained personnel, make sure that
the entire fastening surface is even and smooth (no protruding seams or tile
offset), that the finish of the wall is suitable to apply the product and has no
weak points.
• The filter insert must be used to protect the shower against incoming dirt by
pipework. Incoming dirt leads to defects or/and can damage parts of the
shower; such caused faults voids all liability and guarantee claims.
• The product is not designed to be used with steam baths!
• If the water connections are not stabil mounted, the fitting must be fixed with
2 to 4 extra screws (see page 32, fig. A1 - A11). With this type of installation,
take care not to puncture the water pipe! If the water connections are stabil
mounted, no extra screws are required (see page 33, fig. B1 - B11).
Technical Data
Operating pressure:
max. 1 MPa
27126000 / 27126400Recommended operating pressure:
0,15 - 0,5 MPa
27127000 / 27127400Recommended operating pressure:
0,2 - 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 60°C
Centre distance:
150±12 mm
Connections G 1/2:
cold right - hot left
Thermal disinfection:
70°C / 4 min
• Safety against backflow
• The product is exclusively designed for drinking water!
Symbol description
Do not use silicone containing acetic acid!
Safety Function
(see page 36)
The desired maximum temperature for example max. 42º C can be pre-set thanks
to the safety function.
Adjustment
(see page 36)
After the installation, the output temperature of the thermostat must be checked. A
correction is necessary if the temperature measured at the output differs from the
temperature set on the thermostat.
Maintenance
(see page 40)
• The check valves must be checked regularly according to EN 806-5 in
accordance with national or regional regulations (at least once a year).
• To guarantee the smooth running of the thermostat, it is necessary from time to
time to turn the thermostat from total hot to total cold.
Dimensions
(see page 38)
Flow diagram
(see page 38)
Dismounting handle #98369000
(see page 41)
Spare parts
(see page 44)
Special accessories
(order as an extra)
tile-matching-disk Chrome Plated #92143000 (see page 44)
Cleaning
(see page 42)
Operation
(see page 37)
To empty the overhead shower after use, hold it in a slightly inclined position.
Test certificate
(see page 41)
Fault
Cause
Remedy
Insufficient water
- Supply pressure inadequate
- Check water pressure (If a pump has been installed
check to see if the pump is working).
- Regulator filter dirty
- Clean filter in front of the mixer and on the MTC-ther-
mo cartridge
- filter insert shower dirty
- Clean filter insert between shower and hose
Crossflow, hot water being forced into cold water
pipe, or vice versa, when mixer is closed
- Backflow preventers dirty or leaking
- Clean backflow preventers, exchange if necessary
Spout temperature does not correspond with
temperature set
- Thermostat has not been adjusted
- Adjust thermostat
- Hot water temperature too low
- Increase hot water temperature to 42 ºC to 60 ºC
Temperature regulation not possible
- thermo cartridge calcified
- Exchange thermo cartridge
Safety stop button not operating
- Spring defective
- Button calcified
- Clean spring and/or button, exchange if necessary
Содержание 27126400
Страница 35: ...35 1 2 SW 4 mm SW 17 mm 10 Nm 27126000 27126400 22B 23B 24B 40 C Silicone 25 40 C 26 97708000 ...
Страница 36: ...36 1 2 3 2 1 6 7 8 z B 42 C for example 42 C 5 4 3 2 4 5 1 ...
Страница 43: ...43 1 min A B C D E F 50 mm SW 3 mm 2 Nm 1a 3 4 2 6 SW 3 mm SW 17 mm 45 2 3 1 1b 7 SW 17 mm 10 Nm 45 2 3 1 8 5 ...
Страница 45: ...45 ...
Страница 46: ...46 ...
Страница 47: ...47 ...