background image

5

4

HI935005

HI935005N

SPECIFICATIONS OF 

HI935005 & HI935005N

Main features:

• 

HI766

 K-thermocouple probes

•  Display of temperature in degrees Celsius or Fahrenheit 
•  Range -50 to 1350 °C or -58 to 2462 °F
•  HOLD function
•  HI and LO (Max and Min) temperature values always displayed on 

the LCD

•  Remaining battery life indication / low battery detection
•  Waterproof casing
•  Auto-off capability (

HI935005

 only) 

•  Backlight feature (

HI935005N

 only)

•  User calibration at 0 °C (

HI935005N

 only)

Keyboard Functions:

ON/OFF

 : turn the meter ON and OFF.

HOLD

 : freeze the reading on display. 

°C/°F

 : change reading unit (°C or °F).

CLR

 : clear the HI and LO values.

BL

 (

HI935005N

 only) : toggle the backlight ON and OFF. 

CAL

 (

HI935005N

 only) : press and hold for 5 seconds to enter the

Calibration mode (with reading within ±3 °C range); press to abort
the Calibration mode.

(*) 

Range may be limited by probe.

SPECIFICATIONS

Range (*)

-50.0 to 199.9 °C / 200 to 1350 °C
-58.0 to 399.9 °F / 400 to 2462 °F

Resolution

0.1 °C  (up to 199.9 °C) / 1 °C (outside)
0.1 °F (up to 399.9 °F) / 1 °F (outside) 

Accuracy  
(@20 °C/68 °F)

±0.2% full scale 
for one year, excluding probe error

Typical EMC

 ±3 °C / ±6 °F

Deviation

with HI766 K-thermocouple probe

Battery

3x1.5V AA (IEC LR6) batteries, approx. 
1600 hours of continuous use (BL off)

Auto-off
(HI935005 only)

user selectable: 8 min, 60 min, disabled

Environment

-10 to 50 °C (14 to 122 °F); RH 100%

Dimensions

150 x 80 x 36 mm (5.9 x 3.1 x 1.4")

Weight

235 g (8.3 oz.)

Содержание HI 935005

Страница 1: ...Instruction Manual HI935005 HI935005N HI935002 HI935009 Portable K Thermocouple Thermometers www hannainst com...

Страница 2: ...hich have been designed using the latest microprocessor technology to provide reliable and accurate measurements in a wide temperature range Standard features include K type probes waterproof casing d...

Страница 3: ...ar the HI and LO values BL HI935005N only toggle the backlight ON and OFF CAL HI935005N only press and hold for 5 seconds to enter the Calibration mode with reading within 3 C range press to abort the...

Страница 4: ...ment DISP select Normal Relative or T1 T2 measuring mode ALT HI935009 only enable the second function keys the ALT tag turns on to indicate that the second functions are enabled Note The ALT key can b...

Страница 5: ...updating Hi Lo and relative values In HI935009 only the held value is also stored in non volatile memory and can be recalled by pressing ALT MR key While the MR key is held the HOLD tag lights up and...

Страница 6: ...corresponding tags will light up to inform the user To select the desired channel use the T1 T2 key The 2 channel models are also provided with the DISP function which allows the user to select the i...

Страница 7: ...e made from distilled water Immerse the temperature probe in the center of the ice bath taking care not to touch the ice with the probe tip Ensure that the meter is measuring a temperature within 3 C...

Страница 8: ...ction with the HI766HD probe handle HI766PA Roller surface probe max 320 C 600 F HI766PB Surface probe max 650 C 1200 F HI766PC Penetration probe max 900 C 1650 F HI766PD Air probe max 300 C 570 F HI7...

Страница 9: ...ruments Inc Highland Industrial Park 584 Park East Drive Woonsocket RI 02895 USA www hannainst com Local Office Hanna Instruments Inc Highland Industrial Park 584 Park East Drive Woonsocket RI 02895 U...

Отзывы: