background image

21

21

UP

TIME

ALT

TEMP

UP

DOWN

UP

TIME

ALT

TEMP

INTV

TIME

INTV

TIME

INTV

TIME

LOG

UP

DOWN

TIME

LOG

ALT

TEMP

Example:

Step One

 - Setting the printing/logging interval at 2 minutes:

Press ALT and TIME keys twice. The time will appear on the primary

display with a number representing the printing/logging interval

blinking.

Press either the UP or DOWN keys until a blinking "2" appears.

Press ALT and TIME keys to exit. The display will now show the

current time together with the selected interval of 2 minutes.

Step Two

 - Entering the log mode:

Press ALT and LOG keys. Initially, "

L 01

" will appear on the primary

display.

The meter is now in the printing/logging mode utilizing log number

1

, page 

16

. "LOG" and 

P 15

     shown in the secondary display indicate

that the meter has entered the log mode, and has 

15 

available

pages of memory remaining. After the initial printout, the time and
printing/logging interval will reappear.

Press the LOG key to view the running log and page numbers.

INTV

TIME

LOG

LOG

Untitled-27

22

22

LOG

Press the LOG key again to view the running sample number

Step Three

 - Stopping the printer during the log mode:

After the third printout is completed, press the ALT and PAPER keys.

At this point the meter will continue to log data every 2 minutes but

will no longer print any information. "LOG" will keep blinking on the
secondary display for the remainder of "L 01" (log number 1).

Note:

If the display has shut off press the TEMP key to reactivate it.

Step Four 

- Leaving the log mode:

Once the number of samples stored in memory has reached 10, press
the ALT and LOG keys. The meter will exit the log mode after

generating a log exit status printout.

Step Five 

- Reviewing the stored data in sample number 1:

Press LOG key to enter the memory recall mode. The next available

log and page number will be shown on the display.

Press the ALT and DOWN keys until the number 10 and "L1" appear,
indicating that a total of 10 samples were recorded in log number 1.

LOG

UP

PAPER

ALT

PRINT

LOG

UP

DOWN

TIME

LOG

ALT

TEMP

10-01-96

==01==    0002M

0010    *00.18

LOG

DOWN

ALT

Содержание HI 92804

Страница 1: ...instruments are in compliance with directives EN 50081 1 and EN50082 1 PRELIMINARY EXAMINATION 3 GENERAL DESCRIPTION 3 LCD DISPLAY FUNCTIONAL DESCRIPTION 4 FUNCTIONAL DESCRIPTION HI 92701 AND HI 9270...

Страница 2: ...VDC car battery or a battery charger can also be used to power the unit for extended use HI 92801 and HI 92804 have a memory capacity of 16 000 individual temperature readings with recording intervals...

Страница 3: ...emperature s 11 LOG key to enter the recording mode Untitled 27 6 6 FUNCTIONAL DESCRIPTION FUNCTIONAL DESCRIPTION FUNCTIONAL DESCRIPTION FUNCTIONAL DESCRIPTION FUNCTIONAL DESCRIPTION HI 92801 AND HI 9...

Страница 4: ...92804 Printer Low power impact belt type 14 characters per line using 38 mm plain paper Printing LoggingIntervals 1 2 5 10 15 30 60 120 and 180 minutes Environment 0 to 50 C 32 to 122 F Max 95 RH Dim...

Страница 5: ...the 0 1 1 key to select the 0 1 or 1 resolution With four channels versions all four channels readings automatically change by pressing this key To return the reading to its original resolution simpl...

Страница 6: ...ys to leave this mode The time date and printing interval are now set and stored in the memory even when the display is switched off UP DOWN TIME INTV TIME UP DOWN UP TIME ALT TEMP Untitled 27 12 12 T...

Страница 7: ...dditional probes will not be printed Data from remaining channels can only be added if the recording mode is exited and a new log number is entered A blinking CH will appear on the display next to the...

Страница 8: ...d the LOG symbol will appear on the bottom left corner of the LCD PRINT UP DOWN TIME LOG ALT TEMP LOG Log number Page number CH C LOG 07 0005M 0001 14 25 1 25 0 C 2 27 3 C Untitled 27 16 16 CH C LOG U...

Страница 9: ...LOG symbol will start to blink to indicate that the data are now stored only into memory LOG INTV TIME TEMP 10 01 96 07 0005M 0014 14 25 1 25 0 C 2 27 3 C b c d a e f CH C LOG UP PAPER ALT PRINT Untit...

Страница 10: ...keys as detailed in the chapter TO SCAN STORED DATA ON DISPLAY you can print all or part of that log section by using the ALT and the PRINT keys The printer will start to print the logged section begi...

Страница 11: ...key to view the running log and page numbers INTV TIME LOG LOG Untitled 27 22 22 LOG Press the LOG key again to view the running sample number Step Three Stopping the printer during the log mode Afte...

Страница 12: ...data logger on a HI9200 Infrared Transmitter ensuring that the two infrared LEDs are placed on top of each other The memory can be downloaded to your PC through the HI9200 s RS232 port During the dat...

Страница 13: ...ter automatically returns to the oldest page in the memory and if it contains data it will overwrite In this case the first log will not correspond to the oldest set of data It is recommended to perio...

Страница 14: ...ies are running down If it appears during printing approximately 200 printouts can still be made before the batteries are exhausted When there is only sufficient power for 100 printouts the LO BAT sig...

Страница 15: ...the factory However as a general rule it is recommended to have all thermom eters recalibrated at least once a year For an accurate annual recalibration contact your dealer or the nearest Hanna Custom...

Страница 16: ...13 3 280mm 11 100mm 4 16 5 400mm 15 7 260mm 10 2 155mm 6 1 3mm 0 12 200mm 7 8 5mm 0 20 Untitled 27 32 32 300mm 11 8 30mm 1 2 130mm 5 1 8mm 0 3 HI 766B1 90 surface probe max 450 C 840 F HI 766B2 Surfa...

Страница 17: ...nted for a period of six months This warranty is limited to repair or replacement free of charge Damages due to accidents misuse tampering or lack of prescribed maintenance are not covered If service...

Страница 18: ...or burns do not perform any measurement in microwave ovens HI 92701 HI 92704 HI 92801 HI 92804 DECLARATION OF CONFORMITY We Hanna Instruments Srl V le delle industrie 12 35010 Ronchi di Villafranca PD...

Отзывы: