background image

37

36

WARRANTY

WARRANTY

WARRANTY

WARRANTY

WARRANTY

All Hanna Instruments

 meters are warranted for two years

against defects in workmanship and materials when used for their
intended purpose and maintained according to instructions.

The probes are warranted for a period of six months.

This warranty is limited to repair or replacement free of charge

.

Damages due to accidents, misuse, tampering or lack of prescribed
maintenance are not covered.
If service is required, contact the dealer from whom you purchased the
instrument. If under warranty, report the model number, date of
purchase, serial number and the nature of the failure. If the repair
is not covered by the warranty, you will be notified of the charges
incurred. If the instrument is to be returned to Hanna Instruments,
first obtain a Returned Goods Authorization Number from the Cus-
tomer Service department and then send it with shipment costs
prepaid. When shipping any instrument, make sure it is properly
packaged for complete protection.
To validate your warranty, fill out and return the enclosed warranty
card within 14 days from the date of purchase.

All rights are reserved. Reproduction in whole or in part is
prohibited without the written consent of the copyright owner,
Hanna Instruments Inc., 584 Park East Drive, Woonsocket,
Rhode Island, 02895, USA.

Hanna Instruments reserves the right to modify the design,
construction and appearance of its products without advance
notice.

CALIBRATION TEST PLUGS

Hanna Test Plugs

 provide a quick and easy way to test the meter's

accuracy by simply connecting these Test Plugs to the probe connector
of the meter.
If the reading differs by more than ±0.4°C (±0.8°F) from the Test
Plug value, the unit is due for recalibration.
Choose the right Test Plug to suit your needs:

HI 762-18C

Calibration key,

-18.0°C ±0.4°C

HI 762000C

Calibration key,

0.0°C ±0.4°C

HI 762070C

Calibration key, +70.0°C ±0.4°C

HI 762-004F

Calibration key,

-0.4°F ±0.8°F

HI 762032F

Calibration key, +32.0°F ±0.8°F

HI 762158F

Calibration key, +158.0°F ±0.8°F

ADAPTERS/TRANSFORMERS

HI 710005

Adapter 110 VAC to 12 VDC

HI 710006

Adapter 220 VAC to 12 VDC

OTHER ACCESSORIES

HI 9200

Infrared Transmitter

HI 92000

Windows

®

 compatible software for data transfer to PC

HI 710034

Plain Paper Spare Rolls (10 pcs)

HI 710035

Spare Ink Cartridge (1 pc)

HI 710031

Rugged carrying case

MANRHPRNR2

Instruction manual

Windows

®

 is a registered Trademark of "Microsoft Co."

Содержание HI 9161

Страница 1: ...e in Compliance with the CE Directives HI 9161C ON OFF PAPER RANGE RH 5 0 95 0 C 20 0 60 0 INTV instrum nts e UP PRINT DOWN RANGE LOG MICROPROCESSOR PRINTING THERMOHYGROMETER HI 9161 HI 9261 HI 91610...

Страница 2: ...by the probe into a digital readout in Relative Humidity The standard cable is 2 meters 7 long and a 5 meter 16 5 version is also available Note the RH probe sensor must never come into contact with w...

Страница 3: ...7 5 4 HI 9161C 1 For special applications HI 70606 2 or HI 70606 5 RH probes can also be used These probes come with a sintered cap on the sensor shaft for protection in dusty or corrosive environment...

Страница 4: ...0C 1 FUNCTIONAL DESCRIPTION HI 91610 FUNCTIONAL DESCRIPTION HI 91610 FUNCTIONAL DESCRIPTION HI 91610 FUNCTIONAL DESCRIPTION HI 91610 FUNCTIONAL DESCRIPTION HI 91610 FUNCTIONAL DESCRIPTION HI 9261 FUNC...

Страница 5: ...power impact type belt 14 characters per line using 38 mm plain paper HI 710034 Printing Intervals Selectable from 1 2 5 10 15 30 60 120 180 min Operating Conditions 0 to 50 C 32 to 122 F max RH 98 no...

Страница 6: ...ither the RH or temperature read ing on the display press RANGE The reading will appear without decimal digit when shown on the lower secondary display The tempera ture range on the secondary display...

Страница 7: ...r sensors which provide greater accuracy and faster response than conventional thermistor probes Hanna temperature probes are supplied pre calibrated from the factory and are ready to use Available in...

Страница 8: ...P or the DOWN keys 24 hour clock To memorize the hour press RANGE once again The minutes will start blinking Likewise use UP and DOWN to set the minutes Press the INTV and the RANGE keys simultaneousl...

Страница 9: ...INTV TIME UP DATE DOWN TIME INTV TIME DATE UP To select the hour press the UP or DOWN keys 24 hour clock To set the hour press the TIME key again and the minutes will blink Use the UP or DOWN keys to...

Страница 10: ...5 1 1 5 1 6 5 2 R H 2 5 0 C PRINT To view RH on the primary display press RANGE To view temperature on the primary display when in RH mode press RANGE again If is displayed it indicates that no probe...

Страница 11: ...OFF key The instrument will then make one final exit printout The running log number can be reset by simply removing the batteries 1 0 0 1 9 6 0 1 0 0 0 5 M 0 0 0 6 1 2 0 1 6 5 1 R H 2 5 0 C ON OFF PR...

Страница 12: ...he LOG key The log number and remaining page numbers will appear on display LOG Press the ALT and LOG key simultaneously to enter the logging mode The current log number and the remaining page numbers...

Страница 13: ...ns out the meter will not advise the operator and the printouts could be lost If this hap pens stop the printer by pressing ALT and PAPER key simultaneously Data will be kept in memory Insert a new pa...

Страница 14: ...ON KIT Li Cl 11 1 Na Cl 75 4 CALIBRATION KIT H 2 O 12cc N a C l Li Cl 11 1 Na Cl 75 4 CALIBRATION KIT 12 3 6 9 4 h CALIBRATION KIT Li Cl 11 1 Na Cl 75 4 12 3 6 9 4 h All Hanna thermohygrometers have b...

Страница 15: ...storage or elabora tion without having to connect and disconnect cables between the meter and your PC Data can be further elaborated with the new optional HI 92000 Windows compatible application soft...

Страница 16: ...med reset the printer see page 32 SELF DIAGNOSTIC FUNCTIONS SELF DIAGNOSTIC FUNCTIONS SELF DIAGNOSTIC FUNCTIONS SELF DIAGNOSTIC FUNCTIONS SELF DIAGNOSTIC FUNCTIONS Capacity 8000 data samples which are...

Страница 17: ...tion HI 9161 HI 9261 and HI 91610 can also be used with other adapters supplying a 12VDC output In this case remember to check the correct polarity of your adapter before connecting it to the meter BA...

Страница 18: ...EMPERATURE PROBES These probes use highly sensitive thermistor sensors which provide greater accuracy faster response and a temperature range that is superior to conventional probes All Hanna temperat...

Страница 19: ...te of purchase All rights are reserved Reproduction in whole or in part is prohibited without the written consent of the copyright owner Hanna Instruments Inc 584 Park East Drive Woonsocket Rhode Isla...

Страница 20: ...ons IEC 801 2 Electrostatic Discharge IEC 801 3 RF Radiated IEC 801 4 Fast Transient EN 55022 Radiated Class B Date of Issue 01 02 1996 D Volpato Engineering Manager On behalf of Hanna Instruments S r...

Страница 21: ...A LITERATURE HANNA LITERATURE LAB RECORDING WATER ANALYSIS ENVIROCARE GENERAL CATALOG These and many others catalogs handbooks and leaflets are avail able from Hanna To receive your free copy contact...

Отзывы: