background image

3

2

HI 8033

 and 

HI 933000

 are some of the most complete and versatile

portable conductivity meters ever manufactured.
Designed with utmost precision and simplicity, these meters provide for
up to 3 or 4 measurement ranges.
The conductivity of a solution depends on the temperature and for
this reason measurements are carried out with reference to a
standard temperature of 25°C.
If the solution measured has a different temperature than 25°C,
compensation must be performed.

HI 8033

 compensates for temperature manually, while 

HI 933000,

with a built-in temperature sensor and circuitry, automatically com-
pensates for temperature changes.
The temperature coefficient is fixed at 2%.

Remove the instrument from the packing material and examine it
carefully to make sure that no damage has occurred during shipping.
If there is any noticeable damage, notify your Dealer or the nearest
Hanna office immediately.
Each meter is supplied with:

• Conductivity probe with 1 m (3.3') cable
• Calibration screwdriver (

HI 933000

 only)

• 9V battery and instruction manual

Note:

Save all packing materials until you are sure that the
instrument functions correctly. Any damaged or defective item
must be returned in its original packing materials together
with the supplied accessories.

PRELIMINARY EXAMINATION

GENERAL DESCRIPTION

Dear Customer,
Thank you for choosing a Hanna Product.
Please read this instruction manual carefully before using the instru-
ment. If you need additional technical information, do not hesitate to
e-mail us at 

[email protected]

.

These instruments are in compliance with the 

 directives.

All rights are reserved. Reproduction in whole or in part is prohibited without the
written consent of the copyright owner.

WARRANTY

All Hanna Instruments

 meters are warranted for two years

against defects in workmanship and materials when used for their
intended purpose and maintained according to instructions. 

Probes

are warranted for a period of six months. 

This warranty is

limited to repair or replacement free of charge. Damages due to
accident, misuse, tampering or lack of prescribed maintenance are not
covered. If service is required, contact the dealer from whom you
purchased the instrument. If under warranty, report the model
number, date of purchase, serial number and the nature of the
failure. If the repair is not covered by the warranty, you will be
notified of the charges incurred. If the instrument is to be returned to
Hanna Instruments, first obtain a Returned Goods Authorization
number from the Customer Service department and then send it with
shipping costs prepaid. When shipping any instrument, make sure it
is properly packaged for complete protection.

PRELIMINARY EXAMINATION ...................................................... 3
GENERAL DESCRIPTION .............................................................. 3
FUNCTIONAL DESCRIPTION & SPECIFICATIONS OF HI 8033 ........ 4
FUNCTIONAL DESCRIPTION & SPECIFICATIONS OF HI 933000 .... 5
OPERATIONAL GUIDE ................................................................. 6
CALIBRATION ............................................................................. 7
CONDUCTIVITY VERSUS TEMPERATURE CHART ............................. 9
PROBE MAINTENANCE .............................................................. 10
BATTERY REPLACEMENT ............................................................ 11
ACCESSORIES ........................................................................... 12
CE DECLARATION OF CONFORMITY ............................................ 14

TABLE OF CONTENTS

Hanna Instruments reserves the right to modify the design, construction and

appearance of its products without advance notice.

Содержание HI 8033

Страница 1: ...Instruction Manual HI 8033 HI 933000 Portable Multi Range Conductivity Meters w w w h a n n a i n s t c o m...

Страница 2: ...al information do not hesitate to e mail us at tech hannainst com These instruments are in compliance with the directives All rights are reserved Reproduction in whole or in part is prohibited without...

Страница 3: ...SPECIFICATIONS OF HI 933000 1 Liquid Crystal Display 2 Rotary switch 3 Knob for manual temperature compensation 4 Calibration knob mS Conductivity meter HI 8033 ins rum ns C k S 0 199 9 S 0 1999 S 0...

Страница 4: ...making sure that the holes on the probe are completely submerged If possible use plastic beakers to minimize any EMC interference H I 7 0 3 0 C CALIBRATION Each meter is supplied complete with a 9V ba...

Страница 5: ...440 86 81300 113800 5096 27 80 6 13370 1467 87 83000 115700 5190 28 82 4 13620 1494 89 84900 117700 5286 29 84 2 13870 1521 90 86300 119700 5383 30 86 14120 1548 92 88200 121800 5479 31 87 8 14370 157...

Страница 6: ...EMENT After every series of measurements rinse the probe with tap water If a more thorough cleaning is required remove the PVC sleeve and clean the probe with a cloth or a non abrasive detergent When...

Страница 7: ...80000 S cm 230 mL bottle HI 7035L 111800 S cm 500 mL bottle HI 7035M 111800 S cm 230 mL bottle HI 7039L 5000 S cm 500 mL bottle HI 7039M 5000 S cm 230 mL bottle HI 7032L 1382 ppm mg L 500 mL bottle H...

Страница 8: ...discharges Avoidtouchingtheseringsatalltimes Duringcalibrationoftheinstruments ESDwriststrapsshouldbeworntoavoidpossibledamagetotheprobe by electrostatic discharge Use plastic beakers to minimize any...

Страница 9: ...2 Japan Tel 03 3258 9565 Fax 03 3258 9567 Korea Tel 02 2278 5147 Fax 02 2264 1729 Malaysia Tel 603 5638 9940 Fax 603 5638 9829 Singapore Tel 6296 7118 Fax 6291 6906 SouthAfrica Tel 011 615 6076 Fax 01...

Отзывы: