15
Code
Valid Values
Default
PW
60 Current day
01 to 31
from RTC
no
61 Current month
01 to 12
from RTC
no
62 Current year
1997 to 9999
from RTC
no
63 Current time
00:00 to 23:59
from RTC
no
71 Baud rate
1200, 2400, 4800, 9600
9600 (RS485)
no
90 Display selftest
0: off
1: on
0
yes
91 Keyboard selftest
0: off
1: on
0
yes
92 EEPROM selftest
0: off
1: on
0
yes
93 Relays and LEDs selftest
0: off
1: on
0
yes
94 Watchdog selftest
0: off
1: on
0
yes
99 Unlock password
0000 to 9999
0000
yes
Note
The
process controller automatically checks to ensure that
the entered data matches other related variables. If a wrong
configuration is entered, “WRONG” blinks on the LCD to
prompt the user. The correct configurations are the follow-
ing:
If M1=
/ 0 then S1<HA, S1>LA;
If M2=
/ 0 then S2<HA, S2>LA;
For models other than HI 21523:
If M1= 1 then S1-H1>LA;
If M1= 2 then S1+H1<HA;
If M1= 3 then S1+D1<HA;
If M1= 4 then S1-D1>LA;
If M2= 1 then S2-H2>LA;
If M2= 2 then S2+H2<HA;
If M2= 3 then S2+D2<HA;
If M2= 4 then S2-D2>LA;
If M1= 1 and M2 = 2
then S1-H1>S2+H2, S2>LA, HA>S1;
If M1 = 2 and M2 = 1
then S2-H2>S1+H1, S1>LA, HA>S2;
If M1 = 3 and M2 = 2
then S1>S2+H2, S2>LA, HA>S1+D1;