PRELIMINARY EXAMINATION

Remove the pump from the packing material and examine it carefully
to make sure that no damage has occurred during shipping. If there
is any noticeable damage, notify your Dealer.
Each pump is supplied complete with:

• discharge and suction valves
• LDPE tubing, 7 m (23')
• power cord
• instruction manual

Note:

Save all packing material until you are sure that the pump
functions correctly. Any defective item must be returned in the
original packaging together with the supplied accessories.

READ THE INSTRUCTIONS ATTENTIVELY

BEFORE INSTALLING OR OPERATING YOUR PUMP

The BL electronic dosing pumps are easy to use. We recommend,
however, that you read the entire manual before using the pump.
Familiarity with the features and controls of the unit will give you a
better idea of the dosing potential and help reduce operator errors.
Please operate the pump only as directed in the instruction manual.
Follow all general safety guidelines during operation.
Remember: electrical devices are potentially hazardous. Check that the
voltage of the installation matches the voltage indicated on the
specification label on the back of the pump.

Note:

It is the responsibility of the user to install and ground the
pump properly; it is highly recommended to install an external
switch.

Each pump is protected by a 1 A/250 V fuse that is located together
with 1 spare in a drawer on the power socket under the pump.
Always store chemicals in safe, out of reach places. Follow the
directions for use with each chemical. Do not assume chemicals are the
same because they look alike. Hanna Instruments cannot be held
responsible for the misuse of chemicals or the pump.
Always wear protective clothing (gloves and safety glasses) when
working near chemical dosing pumps. When pumping chemicals,
make sure all tubes are securely attached to the fittings. It is
recommended that tubing is shielded to prevent possible injury in
case of rupture or accidental damage.
Avoid using a pipe wrench or pliers on plastic parts and connectors.

Dear Customer,
Thank you for choosing a Hanna product.
Please read this instruction manual carefully before using the pump.
If you need additional technical information, do not hesitate to e-mail
us at 

[email protected]

.

These instruments are in compliance with the 

 directives.

TABLE OF CONTENTS

PRELIMINARY EXAMINATION ........................................................ 3
GENERAL DESCRIPTION ................................................................ 4
FLOW RATE CHART ....................................................................... 5
FUNCTIONAL DESCRIPTION BL 7916 ............................................ 6
FUNCTIONAL DESCRIPTION BL 7917 ............................................ 7
SPECIFICATIONS ........................................................................... 8
VALVE / HOSE ASSEMBLY DIAGRAM ............................................. 9
MECHANICAL DIMENSIONS ........................................................ 10
INSTALLATION ........................................................................... 11
OPERATIONAL GUIDE ................................................................. 18
pH CALIBRATION ....................................................................... 22
TROUBLESHOOTING GUIDE ........................................................ 23
MAINTENANCE ........................................................................... 24
ELECTRODE CONDITIONING AND MAINTENANCE ........................... 26
TAKING REDOX MEASUREMENTS ................................................. 30
CHEMICAL COMPATIBILITY GUIDE ................................................ 32
ACCESSORIES ............................................................................. 34
CE DECLARATION OF CONFORMITY .............................................. 38

All Hanna Instruments

 pumps are warranted for one year 

against defects in

workmanship and materials when used for their intended purpose and maintained
according to instructions. This warranty is limited to repair or replacement free of
charge. Damages due to accident, misuse, tampering or lack of prescribed main-
tenance are not covered. If service is required, contact the dealer from whom you
purchased the instrument. If under warranty, report the model number, date of
purchase, serial number and the nature of the failure. If the repair is not covered by
the warranty, you will be notified of the charges incurred. If the instrument is to be
returned to Hanna Instruments, first obtain a Returned Goods Authorization Num-
ber from the Customer Service department and then send it with shipment costs
prepaid. When shipping any instrument, make sure it is properly packaged for
complete protection.

WARRANTY

Содержание BL 7917

Страница 1: ...Instruction Manual BL 7916 BL 7917 pH and ORP Measuring Dosing System w w w h a n n a i n s t c o m...

Страница 2: ...near chemical dosing pumps When pumping chemicals make sure all tubes are securely attached to the fittings It is recommended that tubing is shielded to prevent possible injury in case of rupture or a...

Страница 3: ...ch of children and pets All pumps undergo stringent tests to ensure that they comply with their stated specifications and are calibrated at the maximum rated pressure GENERAL DESCRIPTION The BL 7916 a...

Страница 4: ...P electrode 11 Overheating LED 12 Power Socket and Fuse Holder 13 Cable Glands FUNCTIONAL DESCRIPTION BL 7916 1 Discharge Valve Assembly 2 Pump head 3 Suction Valve Assembly 4 Hose 5 Liquid Crystal Di...

Страница 5: ...142 x 181 mm 8 7 x 5 6 x 7 1 Weight Approximately 5 kg 11 lb Range 0 00 to 14 00 pH Resolution 0 01 pH Accuracy 20 C 68 F 0 01 pH Typical EMC Deviation 0 1 pH InputImpedance 10 Ohm Dosage Proportional...

Страница 6: ...r permanent installation The pump can be mounted directly on a wall or tank see page 10 for the specific mounting dimensions Power Requirements BlackStone pumps are designed to operate to specificatio...

Страница 7: ...should be protected from direct exposure to outdoor elements direct sun light rain extreme temperatures high humidity etc Generally speaking the shorter the suction distance the more efficient the pu...

Страница 8: ...nd discharge valves located on the pump head should not be inter changed as they are different internally The discharge valve is fitted with a valve guide and will not function properly if used on the...

Страница 9: ...INSTALLATIONS Flooded Suction Installation Suggested Installation for consis tent output when using a low stroke rate Also suggested for highly viscous chemicals A slight suction pressure avoids self...

Страница 10: ...pump works at 100 of the rating when the difference between measure and setpoint is more than 150 mV BL 7917 or 1 5 pH BL 7916 It goes into proportional dosing for values less than the above You can...

Страница 11: ...ump is stopped when the chemicals are exhausted MANUAL An auxiliary switch can be connected to these terminals to force the unit to pump whatever value is measured by the controller This might be need...

Страница 12: ...nk This vertical distance should not exceed 1 5 meters 5 feet Either lower the pump or raise the feed tank Check the pump head suction and discharge valves for blockage Pump flow rate is reduced Check...

Страница 13: ...Remove the valves from the pump head the injection fitting and the feed Keep the suction and discharge valves separated as they are not interchangeable Disassemble each valve and clean it with a neutr...

Страница 14: ...constantly in a well filled with the sample stream or tank When not in use replace the solution in the protective cap with a few drops of HI 70300 storage solution Follow the Preparation Procedure ab...

Страница 15: ...he cleaning procedures rinse the electrode thoroughly with distilled water drain and refill the reference chamber with fresh electrolyte not necessary for gel filled electrodes and soak the electrode...

Страница 16: ...or reducing power of a solution and are commonly expressed in mV Oxidation may be defined as the process during which a molecule or an ion loses electrons and reduction as the process by which electr...

Страница 17: ...thane Tetraethyl Lead Tetralin Tin Salts Vegetable Oils Vinegar Water Acid Mine Water Fresh Water Distilled Water Salt Whiskey Wines Zinc Chloride Zinc Sulfate Adipic Acid Alcohol Amyl Alcohol Diaceto...

Страница 18: ...L Oxidizing pretreatment solution 500 mL MAINTENANCE SOLUTIONS HI 70300M Storage solution 230 mL botte HI 70300L Storage solution 500 mL bottle HI 7061M General cleaning solution 230 mL botte HI 7061L...

Страница 19: ...5M KCl AgCl electrolyte solution 4x50 mL for single junction electrodes HI 7072 1M KNO3 electrolyte solution 4x50 mL HI 7082 3 5M KCl electrolyte solution 4x50 mL for double junction electrodes RECOMM...

Страница 20: ...e sure that they are entirely suitable for the environ ment in which they are used Operation of these instruments in residential areas could cause unacceptable interfer ence to radio and TV equipment...

Страница 21: ...2 Japan Tel 03 3258 9565 Fax 03 3258 9567 Korea Tel 02 2278 5147 Fax 02 2264 1729 Malaysia Tel 603 5638 9940 Fax 603 5638 9829 Singapore Tel 6296 7118 Fax 6291 6906 SouthAfrica Tel 011 615 6076 Fax 01...

Отзывы: