V. Exclusion from Z-Wave network 
 

The sensor can be excluded from the Z-Wave network by following steps: 

1

Power on the device   

2

Set z-Wave gateway/hub to exclusion mode (see Z-Wave gateway/hub Operation 

Manual)

 

3

Triple click

 the device's Z-Wave button 

 

4

The LED indicator of the sensor will keep flashing quickly. If the exclusion is succeeded, 

the LED light will be flashing slowly (enter the SmartStart function). Otherwise, after a 
timeout of 30 seconds, it will be off and please repeat the operation of step (2) to include to 
the network.

 

 
 

. RESET THE DEVICE 

 
Reset procedure clears the Multisensor’s memory, including Z-Wave network controller 
information. To reset the Multisensor: 
 

1

Power on the device, 

2

press and hold the Z button for more than 20 seconds   

3

If holding time more than 20 seconds, the LED indicator will keep on for 2 seconds, 

which means resetting is complete. 

4

The reset feature works only when the device has been included into a Z-Wave 

network. 

 

Note: 

Use this procedure only in the event that the network primary controller 

is missing or otherwise inoperable. 
 

 

                             
 
 

. ASSOCIATIONS 

 

Association allows Multisensor to control other Z-Wave device such us Smart Switch, 

dimmer,etc. 

Multisensor supports two association groups.   
Multisensor can max associate 5 nodes in each group. 
 
Group 1 reports the conditions of the Multisensor, battery level, temperature, humidity, 

luminance and motion detection. 

Group 2 is assigned to the Multisensor sends BASIC SET command. 

!   

Содержание HKZW-MS08

Страница 1: ...f vendor to increase reliability of the network Multisensor is also a security Z Wave device and supports the Over The Air OTA feature for the product s firmware upgrade If you want your Multisensor t...

Страница 2: ...V 1300mAh Storage environment 40 70 Operational temperature 10 50 Measured temperature range 10 50 Temperature measuring accuracy 2 Measured humidity range 20 RH 80 RH Humidity measuring accuracy 8 RH...

Страница 3: ...nsions 59 59 56mm Working current 100mA Standby current 40uA Recommended installation height 2m PIR detection range Within 8m installation height 2m Installation 1 Power on battery or USB 2 Install th...

Страница 4: ...ion alarms be reported check for any moving objects within the sensor s detection area such as trees blowing in the wind cars passing by windmills False motion alarms may be caused by moving masses of...

Страница 5: ...indicator of the sensor will keep flashing quickly If the inclusion is successfully connected the LED light will be off Otherwise after a timeout of 30 seconds it will be flash ing slowly enter the S...

Страница 6: ...ntroller information To reset the Multisensor 1 Power on the device 2 press and hold the Z button for more than 20 seconds 3 If holding time more than 20 seconds the LED indicator will keep on for 2 s...

Страница 7: ...ds Wake Up Interval Step Seconds 60 seconds Minimum Wake Up Interval Seconds 0 seconds Maximum Wake Up Interval Seconds 3600x24 seconds namely 24h Default Wake Up Interval Seconds 14400 seconds Wake U...

Страница 8: ...IR is triggered send Binary Sensor Report or not Sensor Type Motion 0 don t send 1 send 18 0x12 1 2 The default unit for temperature report 1 degrees Celsius 2 Fahrenheit 19 0x13 1 1 When motion is de...

Страница 9: ...ce pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radi...

Отзывы: