Hank HKZW-MS08 Скачать руководство пользователя страница 3

Radio frequency: 

868.42MHz (EU)   
908.42MHz (US) 

Range: 

More than 100m outdoors 
About 30m indoors 

Dimensions: 

59*59*56mm 

Working current: 

100mA

 

Standby current: 

40uA

 

Recommended installation height: 

2m   

PIR detection range 

Within 8m 

  installation height 2m

 

 

 

. Installation 

 

1

Power on (battery or USB)

 

 

 
 

2

Install the sensor in a desired position using screws or 3M tape

 

 

 
 

3

Insert the Multisensor in it’s holder 

Содержание HKZW-MS08

Страница 1: ...f vendor to increase reliability of the network Multisensor is also a security Z Wave device and supports the Over The Air OTA feature for the product s firmware upgrade If you want your Multisensor t...

Страница 2: ...V 1300mAh Storage environment 40 70 Operational temperature 10 50 Measured temperature range 10 50 Temperature measuring accuracy 2 Measured humidity range 20 RH 80 RH Humidity measuring accuracy 8 RH...

Страница 3: ...nsions 59 59 56mm Working current 100mA Standby current 40uA Recommended installation height 2m PIR detection range Within 8m installation height 2m Installation 1 Power on battery or USB 2 Install th...

Страница 4: ...ion alarms be reported check for any moving objects within the sensor s detection area such as trees blowing in the wind cars passing by windmills False motion alarms may be caused by moving masses of...

Страница 5: ...indicator of the sensor will keep flashing quickly If the inclusion is successfully connected the LED light will be off Otherwise after a timeout of 30 seconds it will be flash ing slowly enter the S...

Страница 6: ...ntroller information To reset the Multisensor 1 Power on the device 2 press and hold the Z button for more than 20 seconds 3 If holding time more than 20 seconds the LED indicator will keep on for 2 s...

Страница 7: ...ds Wake Up Interval Step Seconds 60 seconds Minimum Wake Up Interval Seconds 0 seconds Maximum Wake Up Interval Seconds 3600x24 seconds namely 24h Default Wake Up Interval Seconds 14400 seconds Wake U...

Страница 8: ...IR is triggered send Binary Sensor Report or not Sensor Type Motion 0 don t send 1 send 18 0x12 1 2 The default unit for temperature report 1 degrees Celsius 2 Fahrenheit 19 0x13 1 1 When motion is de...

Страница 9: ...ce pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radi...

Отзывы: