background image

 

 

Send BASIC SET VALUE = 255 to nodes associ-
ated with group 2 when motion alarm is canceled. 

Default setting: 

Parameter size: 

1 [byte] 

 

Parameter No. 17 Enable/disable shock alarm 

0 - Disabled 

1 - Enabled 

Default setting: 

Parameter size: 

1 [byte] 

 

Parameter No. 18 Motion alarm cancellation delay 

The  motion  alarm  will  be  cancelled  in  the  main  con-
troller  and  the  associated  devices  after  3  seconds, 
the  alarm  cancellation  can  be  delay  by  this  parame-
ter. Any motion detected during the cancellation delay 
time  countdown  will  result  in  the  countdown  being 
restarted. 

Available settings: 

0 ~ 65535 [seconds] 

Default setting: 

0 [seconds] 

Parameter size: 

2 [byte] 

 

Parameter No. 32 Level of low battery 

Define a battery level as the “low battery”. 
Available settings: 

10 ~ 50 [%] 

Default setting: 

20 [%] 

Parameter size: 

1 [byte] 

 
 
 
 
 
 
 
 
 

FCC NOTICE (for USA)

 

This  device  complies with  part 15  of  the  FCC  Rules. 
Operation is subject to the following two conditions: 

1)  This  device  may  not  cause  harmful  interference, 

and 

2)  This  device  must  accept  any  interference  re-

ceived,  including  interference  that  may  cause  un-
desired operation. 

 
 
 
 
 

DISPOSING AND RECYCLING

 

When  the  device  reaches  its  end  of  life, 
dispose  it  according  to  your  local  environ-
mental laws, guidelines and regulations. The 
WEEE symbol on the product or the packag-
ing  means  that  according  to  local  laws  and 
regulations it needs to be disposed of sepa-
rately from household waste. 

 

Once  this  product  has  reached  the  end  of  its  life, 
please  take  it  to  a  collection  point  (recycle  facility) 
designated by your local authorities. By recycling the 
product  and  its  packaging  you  help  to  conserve  the 
environment and protect human health. 

 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

MANUFACTURER

 

 

HANK ELECTRONICS CO., LTD 

Address: 

Floor  32

th

,  Block  B,  Dachong  Business 

Center,  Nanshan  District,  Shenzhen, 
China, 518057 

Web: 

www.hank-tech.com 

Tel: 

+86 

– 755 – 26404450 / 82024967 

Fax: 

+86 

– 755 – 26657180 

E-mail 

[email protected] 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
All above is for references only. 
 

Version: 50 / 2020

 

Содержание HKZW-MS02-V1.0

Страница 1: ...MOTION SENSOR HKZW MS02 V1 0 Operating Manual Thank you for your support Please read the user manual carefully before operat ing the device Please keep the user manual for future reference ...

Страница 2: ...R changes It is allowed to be installed on a shelf in the corner of your room anywhere on the wall and even at the ceiling Features list 1 Z Wave series 500 protocol 2 Supports security 0 and security 2 protected mode with AES 128 encryption 3 Tamper alarm by vibration sensor 4 Up to 1 year battery life 5 Low battery alert 6 Supports firmware OTA over the air update ...

Страница 3: ...ly 3V 1x CR123A or USB Standby current about 20µA Working current about 55mA Recommended instal lation height 2m 4m Storage environment 10 50 C 0 80 rH Operating temperature 0 40 C Radio protocol Z Wave Radio frequencies 868 42 MHz EU 908 42 MHz US 921 42 MHz AU ...

Страница 4: ...Range More than 100m outdoors About 30m indoors depending on building materials Dimension 50mm Ø INSTALLATION 1 Turn the cover counter clockwise and open it 2 Remove the battery blocker ...

Страница 5: ...s motion detection area is shown as below The actual range of the sensor can be influenced by environment conditions Should false motion alarms be reported check for any moving objects within the sen sor s detection area such as trees blowing in the wind cars passing by windmills pets etc False motion alarms may be caused by moving masses ...

Страница 6: ...of air and heat as well If the device keeps on reporting false alarms despite eliminating all of the above mentioned factors install the device in another place Approximate detection area ...

Страница 7: ... the adding process to end 6 A successful adding will be confirmed by the Z Wave controller s message Include as a secure device S0 or S2 1 Open the cover 2 Place the device within the direct range of your Z Wave controller 3 Set the Z Wave controller into the security Add in clusion mode see controller operating manual 4 Press and hold the Z Button for more than 3 seconds and then release the LED...

Страница 8: ...or should blink fast 5 Wait for the removing process to end 6 Successful removing will be confirmed by the Z Wave controller s message ASSOCIATION Associations allow the motion sensor to control other Z Wave devices such as Smart Switch Smart Dimmer etc It supports two association groups and can associ ate maximum 5 nodes in each group Group 1 reports the motion detection and battery level Group 2...

Страница 9: ...xamples 0 59 0 seconds the device will not wake up by itself 60 119 60 seconds the device will wake up every 60 seconds RESETTING The reset procedure clears the motion sensor s memory including Z Wave network controller infor mation To reset the motion sensor 1 Power on the device 2 Press and hold the Z Button for more than 20 seconds 3 After holding for 20 seconds the LED indicator will keep on f...

Страница 10: ...byte Parameter No 14 Enable disable BASIC SET command The motion sensor can send a BASIC SET command to nodes associated with group 2 when motion is triggered 0 Disabled 1 Enabled Default setting 0 Parameter size 1 byte Parameter No 15 Value of the BASIC SET The motion sensor can reverse its value of BASIC SET when motion is triggered 0 Send BASIC SET VALUE 255 to nodes associ ated with group 2 wh...

Страница 11: ...tion alarm will be cancelled in the main con troller and the associated devices after 3 seconds the alarm cancellation can be delay by this parame ter Any motion detected during the cancellation delay time countdown will result in the countdown being restarted Available settings 0 65535 seconds Default setting 0 seconds Parameter size 2 byte Parameter No 32 Level of low battery Define a battery le...

Страница 12: ...e device reaches its end of life dispose it according to your local environ mental laws guidelines and regulations The WEEE symbol on the product or the packag ing means that according to local laws and regulations it needs to be disposed of sepa rately from household waste Once this product has reached the end of its life please take it to a collection point recycle facility designated by your lo...

Страница 13: ... Address Floor 32th Block B Dachong Business Center Nanshan District Shenzhen China 518057 Web www hank tech com Tel 86 755 26404450 82024967 Fax 86 755 26657180 E mail sales hank tech com All above is for references only Version 50 2020 ...

Отзывы: