Send BASIC SET VALUE = 255 to nodes associ-
ated with group 2 when motion alarm is canceled.
Default setting:
0
Parameter size:
1 [byte]
Parameter No. 17 Enable/disable shock alarm
0 - Disabled
1 - Enabled
Default setting:
0
Parameter size:
1 [byte]
Parameter No. 18 Motion alarm cancellation delay
The motion alarm will be cancelled in the main con-
troller and the associated devices after 3 seconds,
the alarm cancellation can be delay by this parame-
ter. Any motion detected during the cancellation delay
time countdown will result in the countdown being
restarted.
Available settings:
0 ~ 65535 [seconds]
Default setting:
0 [seconds]
Parameter size:
2 [byte]
Parameter No. 32 Level of low battery
Define a battery level as the “low battery”.
Available settings:
10 ~ 50 [%]
Default setting:
20 [%]
Parameter size:
1 [byte]
FCC NOTICE (for USA)
This device complies with part 15 of the FCC Rules.
Operation is subject to the following two conditions:
1) This device may not cause harmful interference,
and
2) This device must accept any interference re-
ceived, including interference that may cause un-
desired operation.
DISPOSING AND RECYCLING
When the device reaches its end of life,
dispose it according to your local environ-
mental laws, guidelines and regulations. The
WEEE symbol on the product or the packag-
ing means that according to local laws and
regulations it needs to be disposed of sepa-
rately from household waste.
Once this product has reached the end of its life,
please take it to a collection point (recycle facility)
designated by your local authorities. By recycling the
product and its packaging you help to conserve the
environment and protect human health.
MANUFACTURER
HANK ELECTRONICS CO., LTD
Address:
Floor 32
th
, Block B, Dachong Business
Center, Nanshan District, Shenzhen,
China, 518057
Web:
www.hank-tech.com
Tel:
+86
– 755 – 26404450 / 82024967
Fax:
+86
– 755 – 26657180
All above is for references only.
Version: 50 / 2020