9. TROUBLESHOOTING GUIDE
1 PWR Lamp is Turned off but PWR Switch is Turned on
1. PWR Lamp is Turned-off but PWR Switch is Turned-on
2 Not Operating Transmitter but PWR Lamp is Turned-on
3. A function doesn't operate
4. BATTERY'S LIFETIME IS CONSIDERABLY REDUCED
5. Not Operating from a Distance
No.
ITEMS
CAUSE
ACTION
Low Voltage of the Battery
Replace the Battery
Low Voltage of the Battery
Replace the Battery
Bad or Poor Connection in the
Transmitter or the Receiver
Check Connection
Bad or Poor Connection of
the Battery
Check Connection
Working in Auto Power-off Circuit
Turn Off and Turn On the
EMS(Emergency Stop Switch) Button,
then Turn On the Power Switch
Power Switch is Turned-Off in the
Turn On the Power Switch in the
1
PWR Lamp is Turned-off
but PWR Switch is
Turned-on
Receiver
Receiver
Breakdown of Fuse
Replace the Fuse
Bad Button
Replace the Button
2
Not Operating Transmitter
but PWR Lamp is Turned-
on
Bad Relay
Replace the Relay
Bad or Poor Connection of the
Transmitter
Check or Replace the Bad Parts
contact failure of the transmitter
s/w
REPLACE CONNECTION PARTS
RELAY OF RECEIVING POWER
DISCONNECTED
A function doesn't
A function doesn t
operate
4
BATTERY'S LIFETIME IS
CONSIDERABLY
REDUCED
3
Bad or Poor Connection of
the Antenna
Check or Replace the Antenna
Bad RF Module
Replace the RF Module
EXAMINATION WITH THE NAKED
EYE
CHECK THE BROKEN PARTS BY A
SHOCK AND MAINTENANCE
5
Not Operating from a
Distance
6
OTHERS
NO CAUSES FOUND
REQUEST WARRANTY SERVICE