MAINTENANCE AND TROUBLESHOOTING
-
Ⅳ
-
Note: 1. In the welding process, press the MENU key to return to the main interface
and re-set parameters, and then press the ENTER key to enter the welding
interface;
2. In the function selection interface, rotate L Knob to select a welding method
as required and press L Knob two times to directly enter the welding interface.
§4.3Welding parameters
Material
Wire diameter (mm)
GAS
Welding current
(A)
Fe-metal Solid-cored
0.6
CO
2
25-90
Fe-metal Solid-cored
0.8
CO
2
40-150
Fe-metal Solid-cored
0.9
CO
2
50-180
Fe-metal Solid-cored
1.0
CO
2
60-200
Fe-metal Solid-cored
0.6
MIX
25-110
Fe-metal Solid-cored
0.8
MIX
40-180
Fe-metal Solid-cored
0.9
MIX
50-200
Fe-metal Solid-cored
1.0
MIX
60-200