background image

 

- 32 - 

 

8.2.3 Anti-over-heated Device (Independent heater-explosion-proof thermostat and 

probe) 

It's a thermostat switch with probe. It will be active to cut the electric heating when 

the MEDIA TEMPERATURE exceeds limit. It's set to 110 °C. 

 

C

 

8.2.4 Compressor Overload Safety Device (Freezing area) 

It is a Thermal Overload Relay with auto-reset function, responsible for protecting 

the  compressor  from  overloaded.  Once  operated,  the  message  appears  on  the 

display and the machine will stop. 

Alarm
Compressor fault

Solve overload problem or
replace compressor then start

 

This  usually  happens  under  error  operation,  like  setting  the  mix  temperature  too 

low and making the mix over freezes. 

For the reset of the unit, solve overload problem and restart the machine. 

 

8.2.5 Agitator Motor Overload Safety Device (Freezing area) 

It is a Thermal Overload Relay with auto-reset function, responsible for protecting 

the agitator motor from overloaded. Once operated, the message appears on the 

display and the machine will stop. 

Alarm
Motor fault

Solve overload problem or
replace motor then start

 

For the reset of the unit, solve overload problem and restart the machine. 

 

8.2.6 Refrigerate Gas Pressure High Safety Device (Freezing Area) 

When  the  cooling  system  is  not  efficient,  like  the  amount  of  cooling  water  is  not 

enough,  this  part  will  active  to  stop  the  machine  to  prevent  the  compressor  from 

damaged. 

For  the  reset  of  the  unit,  please  wait  at  least  three  minutes  and  make  sure  the 

cooling water supply is enough, then run the machine again. 

 

TM

Содержание HM10C

Страница 1: ...COMBINATION MACHINE INSTRUCTIONS HANDBOOK Version 2 1 MODELS HM5C HM10C HM15C TM...

Страница 2: ...Inc http www hmcompanyusa com Email info hmcompanyusa com This handbook may neither be reprinted reproduced transferred for any commercial purposes nor translated in other languages unless agreed by...

Страница 3: ...1 2 Unpacking 11 1 3 Machine Storage 11 1 4 Disposal of Packing Stuff 11 CHAPTER 2 GENERAL INFORMATION 2 1 Basic Information 12 2 1 1 Nameplate of Machine 12 2 1 2 User s Data 12 2 1 3 Service Declara...

Страница 4: ...ification of Controller 22 5 4 PASTEURIZING AREA 23 5 4 1 Display Screen 23 5 4 2 Increase and Decrease Key 23 5 4 3 Reset Save and Exit Key 23 5 4 4 Pasteurize Key 23 5 4 5 STOP Page Down Key 24 5 5...

Страница 5: ...Device Freezing area 32 8 2 5 Agitator Motor Overload Safety Device Freezing area 32 8 2 6 Refrigerate Gas Pressure High Safety Device Freezing Area 32 8 2 7 Built in Timer Controlled Stop Safety Dev...

Страница 6: ..._______________________________________________________ Handbook Structure This handbook is structuralized in Chapters Sections and Sub sections based on conventional consults habits Chapters A Chapte...

Страница 7: ...ally those components with safety functions are concerned gas pressure switch thermostats sensor magnetic switch etc The following is necessary for concerns above mentioned An instruction handbook rel...

Страница 8: ...afety principle in carrying out the operation described under this symbol may cause an electric shock Caution of General Danger Non compliance with safely principle described related to this symbol ma...

Страница 9: ...f wires should have adequately sized to be compatible to the data on the machine and the diameter of wire is no less than 3mm Before carrying out any kind of maintenance make sure that the machine is...

Страница 10: ...ject to accept the machine Don t open the external package to leave everything as it is Immediately inform the seller and insurance company and make a claim 1 1 1 Moving Notice for Packed Machine To m...

Страница 11: ...the wooden base Make sure safety during all operations mentioned as above Improper operation may cause injury of people crashed or cut by machine even the machine may capsize when it looses balance NO...

Страница 12: ...y manufacture Otherwise the manufacturer will not be responsible for the further warrantee 2 1 4 Information to the User The handbook includes information of machine operation maintenance instruction...

Страница 13: ...combination machine of mix boiler and batch freezer M5C M10C are designed for professional purpose good for making Italian ice cream gelato gourmet ice cream sorbet frozen custard and water ice H M al...

Страница 14: ...ius Degree ambient temperature both water or air cooled Model Dimension mm Width W Depth D Height H HM5C 490 930 920 HM10C 620 580 1200 HM15C 790 655 1430 MODEL Capacity Minimum Input Maximum input Po...

Страница 15: ...ng term and steady operation Voltage Fluctuation 10 Min ambient temperature 10 C Max ambient temperature 43 C Min cooling water temperature 10 C Max cooling water temperature 30 C Min water pressure 1...

Страница 16: ...ondenser The room would be better with enough space for operators to withdraw when necessary Minimum 50 cm from wall or any stuff at rear Minimum 150 cm _______________________________________________...

Страница 17: ...bris It s better to use soften water to prevent that furring appears inside of the pipe to block the pipe and reduce the heat exchange efficiency Water temperature does not exceed 30 degrees Celsius P...

Страница 18: ...laced with same features and carried out by an skilled technician 3 5 Refrigerant Gas Refill The freezing system has been filled with refrigerant gas and inspected by H M before delivery If the machin...

Страница 19: ...of machine should be available at working site for easy reference at any time This handbook must be carefully read and regulations must be followed strictly The technician assigned to checkout and car...

Страница 20: ...teurizing area Bearing Mix tank Stop spring Plastic blade Bottom blade End nut Plastic support Blender frame Seal bearing Seal ring bearing Axis holder Axis Wheel Key Elastic pad End nut Freezing cyli...

Страница 21: ...zing area 4 2 5 Output valve Pasteurizing Area 1 Plastic handle 2 Valve tube 3 4 6 7 Seal ring 5 Fader 8 Extensions tube Aixs Inlet cover Door seal ring Cylinder door Outlet door seal ring Outlet door...

Страница 22: ...f tank it helps to transmit the heat between mix and heater Media temperature is the temperature of this liquid 5 2 Electrical Control Panel 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 PASTEURIZING AREA 1...

Страница 23: ...s an error 5 4 2 Increase and Decrease Key Push increase volume Push decrease volume Under standby mode push both and keys at same time will enter parameters setting mode Details about the parameters...

Страница 24: ...erminate a processing Under parameter setting mode this key acts as Page down Push will move the cursor down 5 4 6 Power On Off key Under STANDBY MODE push will power on the PASTEURIZING area push aga...

Страница 25: ..._______________________________________________ 5 5 2 Parameters Description and Factory Volume 5 6 FREEZING AREA 5 6 1 Display Screen It dynamically shows the statues of machine Ready mode Ready Free...

Страница 26: ...matically Under parameters programming mode push key or will increase or decrease the parameter volume 5 6 3 Reset Save and exit Under parameter setting mode push will save the parameters volume and e...

Страница 27: ...r at any time during freezing The target hardness can be modified freely during the freezing by directly pushing or the new volume will be recorded automatically When the ice cream hardness meets the...

Страница 28: ...y The power indicator blinks after the power source connected The whole system will be activated after the is pressed the indicator will turn on 5 6 7 STOP key The machine will stop running when key p...

Страница 29: ...____________________ 5 7 2 Description of Parameter 5 8 Electric Diagram It s stick on the electric box inside of the machine Parameter Meaning Range Unit Factory volume Hardness T The target hardness...

Страница 30: ...h the food Stainless steel and plastic materials as well as rubber used in the construction and also their particular shapes are designed for easy cleaning but cannot prevent proliferation of mildew a...

Страница 31: ...n Safety Device It monitors the door position When the door is open the computer will forbid all turning to protect the operator and a message appears on the screen Close the door will reset the unit...

Страница 32: ...ix over freezes For the reset of the unit solve overload problem and restart the machine 8 2 5 Agitator Motor Overload Safety Device Freezing area It is a Thermal Overload Relay with auto reset functi...

Страница 33: ...r is programmable _________________________________________________________________ CAUTION It is prohibited to modify or remove the safety devices H M will not be responsible or accept any claim for...

Страница 34: ...he end of selling season and the water inside the pipe should be drained out Otherwise if the outside temperature falls under 0 C the water inside may be frozen and damage the pipe of the machine 9 3...

Страница 35: ...m to ensure the efficiency of freezing Make sure the tightness of the chamber and replace the seal if needed Use long haired brush or compressed air to clear out the dust and other stuff on the conden...

Страница 36: ...d here below are used for the future maintenance which may not be included in the spare parts together with the machine MIXSP 02 MIXSP 11 MIXSP 01 MIXSP 10 MIXSP 09 MIXSP 13 MIXSP 08 MIXSP 07 MIXSP 04...

Страница 37: ...overloading Reduce load Value of motor thermal switch is low Set it to be higher Alarm Compressor Too much refrigerant gas Reduce to correct amount Thermostatic valve not set right Correct valve setti...

Отзывы: