- 32 -
8.2.3 Anti-over-heated Device (Independent heater-explosion-proof thermostat and
probe)
It's a thermostat switch with probe. It will be active to cut the electric heating when
the MEDIA TEMPERATURE exceeds limit. It's set to 110 °C.
C
8.2.4 Compressor Overload Safety Device (Freezing area)
It is a Thermal Overload Relay with auto-reset function, responsible for protecting
the compressor from overloaded. Once operated, the message appears on the
display and the machine will stop.
Alarm
Compressor fault
Solve overload problem or
replace compressor then start
This usually happens under error operation, like setting the mix temperature too
low and making the mix over freezes.
For the reset of the unit, solve overload problem and restart the machine.
8.2.5 Agitator Motor Overload Safety Device (Freezing area)
It is a Thermal Overload Relay with auto-reset function, responsible for protecting
the agitator motor from overloaded. Once operated, the message appears on the
display and the machine will stop.
Alarm
Motor fault
Solve overload problem or
replace motor then start
For the reset of the unit, solve overload problem and restart the machine.
8.2.6 Refrigerate Gas Pressure High Safety Device (Freezing Area)
When the cooling system is not efficient, like the amount of cooling water is not
enough, this part will active to stop the machine to prevent the compressor from
damaged.
For the reset of the unit, please wait at least three minutes and make sure the
cooling water supply is enough, then run the machine again.
TM