background image

1

2

4

5

Alternative 3: End-point charging (Standard version for article number 50100051 and accessory for article number 50100057)

If the end-point charging option is chosen, the lift unit must be fitted with a charger contact (70200062). The charger 
that is included with the lift unit is used. It is connected to the charger rails in the same way as the charger station, see 
section Charger station for charging via hand control. 

1) Check to ensure that the charging points are set for the charger station; the charger plate is secured with the spring 
pins, see fig 1.

2) Check to ensure that the charger plate springs in and out when pressure is applied to the charger plate, see fig 2.

3) Guide the lift unit onto the rail so that the plus on the charging point is on the right side, according to fig 3.

4) Mount charger contacts according to fig 4. NOTE! Push the charger contact (A) in about 50 mm if only a stop bolt is 
used. When an adjustable end-stop is used, the charger contact is pushed in about 90 mm.

5) Affix the accompanying screws for charger contacts, see fig 5 (B). 

6)  Connect the red cable to the charger contact on the right side, the charger plate’s plus side (positive), and the black 
cable on the left side (negative), according to fig 6.

7)  Install the end-stop on the rail.

Spring pin 

3

+

+

+ Plus

6

J

K

L

M

9

1

2

3

4

5

6

7

8

10

11

12

K

G

F

H

J

SCALE:1:5

DWG.  NO.

REV.

NAME

DATE

DRAWN

APPROVED BY

SHEET 1 OF 1

WEIGHT:

COMMENTS:

STATUS:

TITLE

MATERIAL:

SIZE

hc-mabr

In work

End point charger

90001915

00A

Material <not specified>

3441.59 g

2012-01-12

A1

Unless otherwise stated, general 

tolerances according to ISO 2768-m

This drawing and any information or descriptive matter set out hereon are the confidential and copyright property of Handicare

and must not be disclosed, loaned, copied or used for manufacturing, tendering or any other purpose without their written permission.

A

J

K

L

M

9

1

2

3

4

5

6

7

8

10

11

12

K

G

F

H

J

SCALE:1:5

DWG.  NO.

REV.

NAME

DATE

DRAWN

APPROVED BY

SHEET 1 OF 1

WEIGHT:

COMMENTS:

STATUS:

TITLE

MATERIAL:

SIZE

hc-mabr

In work

End point charger

90001915

00A

Material <not specified>

3441.59 g

2012-01-12

A1

Unless otherwise stated, general 

tolerances according to ISO 2768-m

This drawing and any information or descriptive matter set out hereon are the confidential and copyright property of Handicare

and must not be disclosed, loaned, copied or used for manufacturing, tendering or any other purpose without their written permission.

B

+

+

-

+

-

9

M A N U A L

System

RoMedic

TM

Содержание SystemRoMedic RiseAtlas450M QuickTrolleySystem

Страница 1: ...a holistic approach to patient transfers and is organized in four categories transfer positioning support and lifting Visual inspection Inspect lift functions regularly Check to ensure that product is...

Страница 2: ...sing the product 13 18 Important information 13 Before use 13 Safe working load 14 Description of functions and symbols 14 Hand control 15 Information panel 16 Preventive service maintenance 16 Emerge...

Страница 3: ...ssued by Handicare AB Periodic inspection must be performed at least once yearly Use only original spare parts Service and maintenance must be performed according to instructions in the manual The lif...

Страница 4: ...e Holder Charger cup Charger cable EU UK US connectors included fixtures between charger station and wall freestanding rail not included Charger station a Secure holder to charger station on wall free...

Страница 5: ...ESS OTHERWISE SPECIFIED DIMENSIONS ARE IN MILLIMETERS SURFACE FINISH TOLERANCES LINEAR ANGULAR Q A MFG APPV D CHK D DRAWN Fig 2 Trolley in position for mount ing dismounting Trolley quick release Trol...

Страница 6: ...the quick trolley release bracket into the desired angle fig 6 III Mount the top bracket and the covers back to their original position 9000 WEIGHT SEE DETAILS SEE DETA MATERIAL DATE SIGNATURE NAME D...

Страница 7: ...r assembly instructions see Assembly of charger unit 1 The lift unit is charged via a wall mounted charger station Place the hand control in the charger station The charging lamp on the lift unit indi...

Страница 8: ...ig 1 To set the charging points for in rail charging remove the spring pins that hold the charger plate in place Then the dip switch on the circuit board is set for the desired charging function 2 Che...

Страница 9: ...2 Check to ensure that the charger plate springs in and out when pressure is applied to the charger plate see fig 2 3 Guide the lift unit onto the rail so that the plus on the charging point is on th...

Страница 10: ...t is activated the battery symbol lights up for two seconds to indicate the current battery status Battery status in rail charging The battery symbol lights green when battery capacity exceeds 50 When...

Страница 11: ...lley T bracket into the trolley Then rotate the lift unit 90 degrees to lock the QuickTrolleyReleaseBracket into the trolley picture 1 4 below Ensure that the lift unit slides in place and that it can...

Страница 12: ...t lift function by lifting a person not a patient using an approved sling At the same time check both the manual and electrical emergency lowering function with someone in the lift See section on Emer...

Страница 13: ...or alterations are made to the lift by personnel who are not authorized RiseAtlas must not come in direct contact with water RiseAtlas must not be charged in a wet room article no 50100057 To ensure...

Страница 14: ...in the manual for the respective accessory Below is a brief description of the functions that are available for caregivers and patients Symbols on the product Battery status Emergency stop The lift r...

Страница 15: ...ut 2 seconds to indicate battery status If the lamp does not light check to ensure that the emergency stop is not activated Active safety RiseAtlas has a built in strap guard which prevents the lift f...

Страница 16: ...e lift again Night light RiseAtlas is equipped with night lighting which will be activated by pressing and holding the ON button on the hand control for 3 seconds The LED lamp lights for 15 minutes if...

Страница 17: ...as the emergency stop strap fig 3 On the inside of the cover there is an Allen key Remove the Allen key and insert it into the hole as indicated fig 4 Turn it counter clockwise to lower and clockwise...

Страница 18: ...on that load is applied to the lift strap If the lift unit is not working properly contact your Handicare dealer If the lift cannot be run all the way up to stop check to ensure that the overload symb...

Страница 19: ...icle no 70100002 300 kg 661 lbs Article no 70100003 400 kg 881 lbs Assistive devices for positioning SystemRoMedic includes a wide range of functional comfortable high quality assistive devices for po...

Страница 20: ...th warm water or rubbing alcohol Do not use cleaning agents containing phenol or chlorine as this may damage the material Storage To ensure maximum battery life charge regularly We recommend that the...

Страница 21: ...ch SWL RiseAtlas450M 205 kg 450 lbs Sound level Unload 55 dB Max load 57 dB Pressure hand control Buttons on hand control 4 N Lift measurements 26 6 x 15 1 x 15 6 cm 10 5 x 5 9 x 6 1 inch Intermittent...

Страница 22: ...ch SWL RiseAtlas450M 205 kg 450 lbs Sound level Unload 55 dB Max load 57 dB Pressure hand control Buttons on hand control 4 N Lift measurements 26 6 x 15 1 x 15 6 cm 10 5 x 5 9 x 6 1 inch Intermittent...

Страница 23: ...23 0 cm 9 inch Installation height on SlingBar M 32 7 cm 12 8 inch Article no 50100057 Article no 50100051 1 Outlet for hand control 2 Hand control 3 Lift strap 4 Emergency stop and electrical emergen...

Страница 24: ...inde pendence and dignity Through a combination of training and a complete range of transfer assistive devices SystemRoMedic offers the means to improving both the work environment and the quality of...