background image

2–15

SCANTEAM 5700 User’s Guide

Enable

 Disable

Require Data Format

Enter Data Format

Clear All Data Formats

Data Format Editor

Status Check

Show Formats

Scan the 

Show Formats

 bar code to transmit the existing Data Format Editor

formats.  One format per line will be printed out.

When disabled, the bar code data will be output to the host as scanned (including
prefixes and suffixes).  When enabled, all input data must conform to an edited
format or the scanner will not transmit the input data to the host device.

See pages 2–14 and 2–16 through 2–17 for a description of this selection and
examples.

Содержание Scanteam 5700

Страница 1: ...Decoded Output ...

Страница 2: ... Allyn shall not be liable for technical or editorial errors or omissions contained herein nor for incidental or consequential damages resulting from the furnishing performance or use of this material This document contains proprietary information which is protected by copyright All rights are reserved No part of this document may be photocopied reproduced or translated into another language witho...

Страница 3: ... will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures FCC Class B Compliance Statement Caution Any changes or modifications made to this device that are not expressly ...

Страница 4: ... 053 5 408 081 5 410 139 5 436 440 5 468 949 5 479 000 5 942 741 Other U S and foreign patents pending Patents Welch Allyn shall not be liable for use of our product with equipment i e power supplies personal computers etc that is not CE marked and does not comply with the Low Voltage Directive For further information please contact Welch Allyn Ltd 1st Floor Dallam Court Dallam Lane Warrington Che...

Страница 5: ...l Interface Selections Programming Instructions 1 14 Code 39 Wand Emulation Selection 1 15 Same Code Wand Emulation Selection 1 15 RS 232 Selection 1 15 Laser Emulation Selection 1 15 Dual Interface Enable Disable Selection 1 16 Switched Power Mode Selections 1 16 Laser Emulation Power Up Delay Selection 1 16 Section 2 Output Parameters Menu Section Page Prefix Suffix Selections Introduction 2 1 P...

Страница 6: ...RS 232 Word Length Selection 2 12 Parity Selection 2 12 Protocol Selection 2 13 Serial Wedge Output Selection 2 13 Data Formatter Selections Status Check 2 15 Require Data Format 2 15 Data Format Editor 2 15 Section 3 General Operating Menu Section Page Laser Options Introduction 3 1 Marker Beam Selection 3 2 AutoTrigger Selection 3 2 Wand Emulation Selections Transmission Rate Selection 3 3 Wake ...

Страница 7: ...Selection 4 11 Retail Symbology Selections EAN Selection 4 12 UPC Selection 4 13 EAN Addenda Selection 4 14 UPC Addenda Selection 4 14 MSI Selection 4 15 Plessey Selection 4 15 Section 5 Firmware Utility Menu Section Page Introduction 5 1 Downloading Utility 5 2 Uploading Utility 5 2 Cloning Utility 5 3 Temporary Serial Communication Configuration 5 3 Section 6 Supported Interface Keys Section Pag...

Страница 8: ... Troubleshooting Section Page Maintenance 8 1 Troubleshooting 8 3 Section 9 Customer Service Section Page Obtaining Factory Service 9 1 Technical Support 9 2 Limited Warranty 9 2 Default Charts Programming Chart inside back cover Sample Bar Codes back cover ...

Страница 9: ...and formatting capabilities and multiple interface connectivity The scanner can be programmed for many communications parameters and input output protocols compatible to the host Programming is accomplished by using the single programming bar codes in this menu Use this chapter to program your laser scanner to work with your terminal computer Introduction Section 1 Introduction Quick Start Menu Th...

Страница 10: ...arious DEC Only RS 232 Wedge D Model Number 5X00 A 12 Scanner Identification AutoTrigger Option 0 Hands Free AutoTrigger Feature Not Included 1 Hands Free AutoTrigger Feature Included Engine Type A Increased Performance Operates only from 5V power source for 5700 A Operates only from either 5 or 12V power HD High Density ALR Advanced Long Range Manufactured Month Year ModelNumber 5X00 A 12 SerialN...

Страница 11: ... terminal or computer by scanning the Terminal Set Up Codes Either scan the Plug and Play codes Pages 1 7 to 1 10 or use the Supported Terminal list Pages 1 11 to 1 12 to determine your terminal s Terminal ID With Plug and Play programming you connect the scanner and scan only one bar code to program the scanner to work with a designated interface including any required prefixes and suffixes To de...

Страница 12: ...0 0 2 5 08 4 10 2 6 15 2 8 20 3 10 25 4 12 30 5 14 35 6 16 40 6 18 45 7 20 50 8 22 55 9 24 61 26 66 28 71 1 30 76 2 32 81 3 In Cm 9 65 24 511 9 65 24 511 5 mil 2 5 3 5 7 5 mil 2 7 20mil 1 5 18 40 mil 3 5 26 55 mil 4 31 19 3 Typical Performance at 20 C for SCANTEAM 5700 A 1 13 mil 14 ...

Страница 13: ...5 08 1 2 54 0 0 1 2 54 2 0 3 3 mil 1 0 2 5 5 5 mil 7 5 mil 4 0 4 5 In Typical Depth of Field in Inches Centimeters Cm 0 0 1 2 54 2 5 08 3 7 62 4 10 16 5 12 7 6 15 24 Typical Performance at 20 C for SCANTEAM 5700 HD 2 8 13 mil 6 0 5 1 0 10 mil 5 5 5 ...

Страница 14: ...formance at 20 C for SCANTEAM 5700ALR 100 mil 322 123 30 104 1 20 76 2 10 50 8 25 4 0 0 25 4 10 50 8 20 76 2 30 104 1 41 30 mil 43 22 99 40 70 mil retroreflective 68 172 7 cm 13 5 411 5 cm 100 mil retroreflective 82 208 3 cm 17 5 533 4 cm 30 60 120 150 210 240 300 330 0 228 6 457 2 685 8 914 4 76 2 152 4 304 8 381 0 533 4 609 6 762 0 838 2 ...

Страница 15: ...e return CR suffix also PS 2 30 286 50 55SX 60 70 70 061 70 121 80 for PS 2 25 30 models Wand Emulation Code 39 Format Interface Wand Emulation Same Code Format Interface Supports Code 39 UPC EAN Code 128 Interleaved 2 of 5 and Codabar All other codes output as Code 39 Transmission Rate 20 inches per second Output Polarity Black High Programmable Option Setting These bar codes also program the fol...

Страница 16: ...e IBM 4683 Port 9B HHBCR 1 Interface IBM 4683 Port 9B HHBCR 2 Interface IBM 4683 Port 17 Interface EAN 8 0C Code 39 00 0A 0B EAN 13 16 I 2 of 5 00 0D 0B UPC A 0D Code 128 00 18 0B UPC E 0A Symbology Suffix Symbology Prefix These bar codes also program the following parameters ...

Страница 17: ...refix EAN 8 0F 0F UPC A 0A EAN 13 0F UPC E 0E Symbology Suffix Symbology Prefix EAN 8 46 46 Code 39 42 31 EAN 13 46 I 2 of 5 42 32 UPC A 41 Code 128 42 33 UPC E 45 Symbology Suffix Symbology Prefix The bar code above also programs the following parameters The bar code above also programs the following parameters This bar code above also programs the following parameters Nixdorf OCIA Interface EAN ...

Страница 18: ...CR Interface OCR RS232 Interface IBM OCR Port 21 Interface Symbology Suffix Symbology Prefix Symbology Suffix Symbology Prefix The bar code above also programs the following parameters RS 232 Interface Baud Rate 9600 bits per second Parity even Data Format 7 data bits parity bit 1 stop bit 8 Bit Data The bar code above also programs the following parameters Programmable Option Setting End of Plug ...

Страница 19: ...T PS 2 30 286 50 55SX 03 60 70 70 061 70 121 80 IBM 4683 4684 51 IBM 102 Key 3151 3161 3162 3163 3191 06 3192 3196 3197 3471 3472 3476 3477 IBM 122 Key 3179 1 3191 3192 3471 07 3472 3194 IBM 122 Key 3196 3197 3476 3477 08 3486 3488 3482 IBM 122 Key 3180 24 Program Terminal Interface If your terminal is not one of the Plug and Play options you must program one of the terminals listed below To progr...

Страница 20: ... Qume Enhanced PC QVT 61 62 70 82 191 Qx15 38 RS232 True 00 RS232 TTL 00 Serial Wedge 50 Siemens 9758 German Only 34 Stratus V103 14 Televideo 955 965 36 Telex 88 Key 078A 078 79 80 191 196 25 1191 1192 1471 1472 1476 Telex 102 Key 078A 078 79 80 191 196 45 1191 1192 1471 1472 1476 Telex 122 Key 078A 078 79 80 191 196 46 1191 1192 1471 1472 1476 Wand Emulation 61 WYSE WY 30 13 WYSE WY 85 185 16 WY...

Страница 21: ...on requires it scan the Program Carriage Return Suffix bar code to program a carriage return CR suffix for all enabled bar code symbologies Scanning this bar code clears all previously programmed prefixes and suffixes Scan the Clear Bar Code Suffix bar code to disable or clear all previously programmed prefixes and suffixes e g the carriage return suffix Scan the Show Software Revision bar code to...

Страница 22: ...ondary interface from one selection to another e g from HHLC to RS 232 the scanner must be reconnected to the primary interface and then reprogrammed for the new secondary interface Connect the scanner to the primary interface cable Follow steps 1 4 above Scanning Plug and Play bar codes single scan terminal selection bar codes or changing the terminal type does not affect Dual Interface settings ...

Страница 23: ...Code 39 Wand Emulation Selection Same Code Wand Emulation Selection RS 232 Selection RS 232 Selection Laser Emulation Selection Laser Emulation Selection Supports Code 39 UPC EAN Code 128 Interleaved 2 of 5 and Codabar All other codes output as Code 39 Note 5700 X3 units do not support Dual Interface ...

Страница 24: ... When this feature is enabled the unit consumes less than 50 uA from its power line when the trigger is not pulled When the trigger is pulled it consumes normal power This feature is used for battery powered devices to save power If power savings is not an issue and speed is disable this feature for better performance Scan two of the Numeric Bar Codes on the Programming Chart inside back cover to ...

Страница 25: ...se this chapter to program the output parameters for the Hand Held Laser Scanner This programming section contains the following menuing selections Prefix and Suffix Output Serial Communication RS 232 Data Formatter Section 2 Serial Interface Menu ...

Страница 26: ...ng bar code This exits without changing the Prefix Suffix Other Programming Selections Scanning the Clear All Primary Prefixes or Clear All Primary Suffixes bar code deletes all Primary Prefix or Suffix selections You don t need to scan the Save Current Changes or Discard Current Changes programming bar code to complete programming H Save Current Prefix or Suffix Changes programming bar code This ...

Страница 27: ...ix Selection Exit Selection for Prefix Suffix Discard Current Prefix or Suffix Changes Clear All Primary Suffixes One or more two digit numbers are required after scanning this programming bar code Please scan your selection on the Programming Chart inside back cover Clear One Primary Prefix Clear One Primary Suffix Save Current Prefix or Suffix Changes ...

Страница 28: ...gramming bar code This exits without changing the Prefix Suffix Other Programming Selections Scanning the Clear All Secondary Prefixes or Clear All Secondary Suffixes bar code deletes all Secondary Prefix or Suffix selections You don t need to scan the Save Current Changes or Discard Current Changes programming bar code to complete programming H Save Current Prefix or Suffix Changes programming ba...

Страница 29: ... Suffix Selection Exit Selection for Prefix Suffix Discard Current Prefix or Suffix Changes Clear All Secondary Suffixes One or more two digit numbers are required after scanning this programming bar code Scan your selection on the Programming Chart inside back cover Clear One Secondary Prefix Clear One Secondary Suffix Save Current Prefix or Suffix Changes ...

Страница 30: ...Symbologies You want to send a HT tab Prefix for UPC only and a CR LF carriage return line feed Suffix for all symbologies H Scan the Add Suffix Suffix Selection bar code H The Symbology Chart indicates that the Hex value for All Symbologies is 99 Scan 9 and 9 on the Programming Chart H A CR is equivalent to 0D and an LF is 0A Scan 0 D 0 and A on the Programming Chart H Scan the Save Current Prefi...

Страница 31: ... 44 45 46 47 48 49 4A 4B 4C 4D 4E 4F P Q R S T U V W X Y Z _ 50 51 52 53 54 55 56 57 58 59 5A 5B 5C 5D 5E 5F a b c d e f g h i j k l m n o 60 61 62 63 64 65 66 67 68 69 6A 6B 6C 6D 6E 6F p q r s t u v w x y z DEL 70 71 72 73 74 75 76 77 78 79 7A 7B 7C 7D 7E 7F Note Prefix Suffix entries for specific symbologies override the universal All Symbologies 99 entry Note Adding a Prefix or a Suffix append...

Страница 32: ...en data output by the scanner to the host terminal The actual delay is 5 milliseconds multiplied by the programmed value 00 99 Default 00 Example You need a 45 millisecond delay Scan the Intercharacter Delay bar code Then scan 0 and 9 on the Programming Chart 09 x 5ms 45 ms Intercharacter Delay is the time delay between data characters output by the scanner to the host terminal Interfunction Delay...

Страница 33: ...e bar code Longer delays are effective in minimizing accidental rereads at POS point of sale terminals Use shorter delays in applications where repetitive bar code scanning is required This selection allows you to set a time period that must pass before the scanner can read another bar code Some terminals require a slower read rate By setting a good read delay you can ensure a good read When Laser...

Страница 34: ...y code which corresponds to the decoded ASCII function code to the terminal ASCII function codes are represented by the HEX values 00 1F Charts of these function codes are shown in Section 6 Supported Interface Keys This selection allows you to enable or disable transmission of an AIM I D before the decoded bar code symbology See AIM Guidelines on Symbology Identifiers for more information on the ...

Страница 35: ...t the software programming feature that checks for a CTS signal if your application does not have a CTS I O line Default Disable This selection sets the baud rate from 300 bits per second to 38 400 bits per second Programming baud rate causes the data to be sent at the specified rate The host terminal must be set up for the same baud rate as the scanner to ensure reliable communication Default 960...

Страница 36: ... at one each If an application requires only ASCII Hex characters 0 through 7F decimal text digits and punctuation select 7 data bits For applications requiring use of the full ASCII set select 8 data bits per character This selection provides a means of checking character bit patterns for validity The scanner can be configured to operate under Even Odd Mark None or Space parity options The host t...

Страница 37: ...devices The scanner supports Record Xon Xoff and Ack Nak protocols when receiving data from an RS 232 device This selection allows you to select the serial output direction required by your application P1 and P2 are serial wedge designations printed on the serial wedge cable Usually one goes to the host and one goes to the terminal depending on your specific application and the serial wedge cable ...

Страница 38: ...he Hex Value column that represent the Code I D of the symbology you want formatted All Symbologies hex value 99 is not supported by Data Formatter Length Scan two numeric bar codes inside back cover for the bar code length you require 00 99 Be sure to include spaces To make Data Format Editor selections you must know the terminal type code I D code length and editor commands your application requ...

Страница 39: ... the existing Data Format Editor formats One format per line will be printed out When disabled the bar code data will be output to the host as scanned including prefixes and suffixes When enabled all input data must conform to an edited format or the scanner will not transmit the input data to the host device See pages 2 14 and 2 16 through 2 17 for a description of this selection and examples ...

Страница 40: ...ion Syntax F5NN NN number of characters 00 99 DEC F6 Move cursor back NN characters from current cursor position Syntax F6NN NN number of characters 00 99 DEC F7 Move cursor to the beginning of the data string Syntax F7 Search Commands F8 Search ahead for XX character from current cursor position leaving cursor pointing to XX character Syntax F8XX XX HEX ASCII character 00 7F F9 Search back for XX...

Страница 41: ...A with 5 digit addenda 56098 0 12345 67890 5 Refer to the Format Editor Commands Chart on page 2 16 to format the following example The programming bar codes on pages 2 15 and the alpha numeric bar codes on the inside back cover are used to program the data formatter H Scan the 63 bar codes the Hex value for UPC symbology H Scan the 18 bar codes for the bar code length H Scan the FB suppress chara...

Страница 42: ...2 18 SCANTEAM 5700 User s Guide ...

Страница 43: ...s Guide Introduction Use this chapter to program the Hand Held Laser Scanner for General Operating features This programming section contains the following menuing selections Laser Options Wand Emulation Country Code Keyboard ...

Страница 44: ...begins The marker beam emitted by centering the optical scan mirror appears as a bright spot of illumination that serves as an aiming guide when bar code targets are at a distance from the scanner Note Applies only to the 5700ALR product When enabled this programming selection allows auto triggering with the optional Scan Stand The Scan Stand provides hands free operation in any application where ...

Страница 45: ...nsmission rate causes the data to be sent at the specified rate The programmed transmission rate must be compatible with the device receiving the bar code data Default 25 ips inches per second This selection provides a wake up pulse on the sync line from the scanner to a portable terminal This feature extends battery life of the portable terminal by waking up the terminal only when data is ready t...

Страница 46: ...e selected country As a general rule the following characters are not supported by the scanner for countries other than the United States United States Belgium Foreign Keyboard Selection Denmark Finland Norway Sweden France Germany Austria Italy Switzerland United Kingdom Denmark Wyse only Norway Wyse only ...

Страница 47: ... connect the scanner directly to your terminal No keyboard is necessary when this selection is enabled Default Disable This selection allows you to program the scanner to transmit the proper keycodes when interfacing with a telephone calculator or PC AT type numeric keypad layout Choose the keypad layout that defines your keypad layout Default Layout 1 Telephone Note A direct connect cable is opti...

Страница 48: ...supported Style B Style C Style D IBM PC XT XT CAPS LOCK Keyboard Style Terminal SHIFT LOCK Style E Gr DOS SHIFT LOCK IBM PC AT AT CAPS LOCK SHIFT LOCK CTRL ASCII Gr DOS SHIFT LOCK IBM PS2 50 80 NORM CAPS LOCK SHIFT LOCK Gr DOS SHIFT LOCK HDS 2000 3200 T W CTRL IBM 3180 122 Key T W D E COMTERM 6178 T W D E TELEX 88 Key T W D E SIEMENS 9758 NORM CAPS LOCK NCR 7052 34Key 56 Key 122 Key Caps On 122 K...

Страница 49: ...ards Automatic Caps Lock is used if you change the Caps Lock key on and off The software tracks and reflects if you have Caps Lock on or off AT and PS 2 only This selection can only be used with systems that have an LED which notes the Caps Lock status Emulate External Keyboard should be scanned if you do not have an external keyboard IBM AT or equivalent Keyboard Style Selections Regular Automati...

Страница 50: ...On sends numeric characters as if entered from a numeric keypad Default Off Default All This sets all Keyboard Style Modifiers to their default states Control ASCII Mode Off Turbo Mode Off Numeric Keypad Mode Off Automatic Direct Connect When Emulate External Keyboard has been selected page 3 7 Automatic Direct Connect Mode keeps the integrated keyboard from becoming permanently disabled Default O...

Страница 51: ...ramming section contains the following menuing selections Codabar Selections Code 39 Selections Code 93 Selections Interleaved 2 of 5 Selections Code 2 of 5 Selections Matrix 2 of 5 Selections Code 11 Selections Code128 Selections Code 16K Selections Code 49 Selections EAN Selections UPC Selections MSI Selections Plessey Selections Section 4 Symbology Menu ...

Страница 52: ...essage Length Maximum Minimum A two digit number is required after scanning this programming bar code Scan your selection on the Programming Chart inside back cover Codabar Selection Decoding Adaptive Traditional Programming Tip If a symbology will not be used we recommend turning it off to minimize the chance of a misread ...

Страница 53: ...ou Allow concatenation the reader will look for a Codabar symbol having a D start character adjacent to a symbol having a D stop character In this case the two messages are concatenated into one with the D characters omitted Select Require to prevent the reader from decoding a lone Codabar symbol A12D D34A Star t Character Stop Star t Stop Codabar Programming Tip If a symbology will not be used we...

Страница 54: ...e Disable Append Enable Disable A two digit number is required after scanning this programming bar code Scan your selection on the Programming Chart inside back cover Code 39 Selection Refer to the Full ASCII Chart on page 4 6 Programming Tip If a symbology will not be used we recommend turning it off to minimize the chance of a misread ...

Страница 55: ...t No Check Character Validate And Transmit Check Character Code 39 Selection continued Message Length Maximum Minimum Decoding Adaptive Traditional Programming Tip If a symbology will not be used we recommend turning it off to minimize the chance of a misread ...

Страница 56: ... I J K L M N O V A B C D E F G H I J K L M N O P Q R S T U V W X Y Z _ P Q R S T U V W X Y Z K L M N O a b c d e f g h i j k l m n o W A B C D E F G H I J K L M N O p q r s t u v w x y z DEL P Q R S T U V W X Y Z P Q R S T This chart is used for encoding the above characters in Full ASCII when using Code 39 bar codes For example to get a encode G which is 25 47 on the Hex ASCII chart in the Prefix...

Страница 57: ...heck Digit Interleaved 2 of 5 Selection A two digit number is required after scanning this programming bar code Scan your selection on the Programming Chart inside back cover Default All Interleaved 2 of 5 Settings Decoding Adaptive Traditional Programming Tip If a symbology will not be used we recommend turning it off to minimize the chance of a misread ...

Страница 58: ... Matrix 2 of 5 Selection Code 2 of 5 Selection A two digit number is required after scanning this programming bar code Scan your selection on the Programming Chart inside back cover Default All Matrix Code 2 of 5 Settings Programming Tip If a symbology will not be used we recommend turning it off to minimize the chance of a misread ...

Страница 59: ...number is required after scanning this programming bar code Scan your selection on the Programming Chart inside back cover Code 11 On Off 2 Check Digits 1 Check Digit Code 11 Selection Message Length Maximum Minimum Check Digits Required Programming Tip If a symbology will not be used we recommend turning it off to minimize the chance of a misread ...

Страница 60: ...ner can substitute a GS for function character 1 To enable the GS substitution you must scan the Code 128 Function Character On bar code and the GS Substitution On bar code Note For complete Code 128 support the AIM ID Transmit selection should also be enabled Refer to page 2 10 Code 128 Function Character On Off GS Substitution ...

Страница 61: ...ning this programming bar code 16K may accept a 3 digit number Scan your selection on the Programming Chart inside back cover Default All Code 16K Code 49 Settings Code 16K On Off Code 49 On Off Not in standard product Contact your Welch Allyn Sales Coordinator Programming Tip If a symbology will not be used we recommend turning it off to minimize the chance of a misread ...

Страница 62: ...N 13 On Off EAN JAN 8 On Off Check Digit Transmit Don t Transmit Default All EAN UPC Settings EAN Selection ISBN Enable Disable Programming Tip If a symbology will not be used we recommend turning it off to minimize the chance of a misread ...

Страница 63: ... Off Check Digit Transmit Don t Transmit Number System Transmit Don t Transmit Version E Expand Expand Don t Expand Default All UPC EAN Settings UPC Selection Programming Tip If a symbology will not be used we recommend turning it off to minimize the chance of a misread ...

Страница 64: ... Disable EAN UPC Addenda Require Don t Require UPC Addenda Selection EAN Addenda Selection Two Digit Addenda Enable Disable Five Digit Addenda Enable Disable EAN UPC Addenda Format No Space Space Note The EAN UPC Addenda Format bar codes below apply to software revision level 2 0 and greater ...

Страница 65: ...ximum Minimum A two digit number is required after scanning this programming bar code Scan your selection on the Programming Chart inside back cover MSI On Off Message Length Maximum Minimum MSI Selection Programming Tip If a symbology will not be used we recommend turning it off to minimize the chance of a misread ...

Страница 66: ...4 16 SCANTEAM 5700 User s Guide ...

Страница 67: ...r The scanner also has a special cloning capability Cloning provides a quick convenient way to re program installed scanners from a master unit containing new or updated firmware eliminating the need to use a PC for each serial download After upgraded firmware is downloaded into the master unit the master may be used to program other scanners A cloning cable is used and may be ordered from your di...

Страница 68: ...ads reading the device s memory and downloads writing to the device s memory The Quick Load application will prompt you to scan the symbol shown below at the appropriate time Scanning the Memory Upload bar code sends the entire contents of ROM to the host terminal The data is transmitted serially as INTEL formatted ASCII text strings at 19 200 baud no parity 8 data bits and 1 stop bit Download New...

Страница 69: ...transfer the firmware contents of the master unit to the destination or installed unit First you must follow the steps below to initiate the cloning procedure 1 Connect the destination installed unit to one of the 8 pin modular connectors on the cloning cable 2 Connect the master unit containing the new or updated software to the remaining 8 pin modular connector on the cloning cable 3 Make sure t...

Страница 70: ...5 4 SCANTEAM 5700 User s Guide ...

Страница 71: ...following Keyboard Function Code Hex ASCII Value and Full ASCII CTRL relationships apply to all terminals that can be used with the Hand Held Decoded Output Laser scanner Function Code HEX ASCII Value Full ASCII CTRL The last five characters in the Full ASCII CTRL column 6 apply to US only The following chart indicates the equivalents of these five characters for different countries Country United...

Страница 72: ...ce Back Tab F12 F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 IBM AT XT and PS 2 Compatibles WYSE PC AT Reserved CR Enter Caps Lock Reserved Reserved Reserved Reserved CR Enter Reserved Tab Reserved Tab Delete CR Enter Insert Escape Reserved Home Print Back Space Back Tab Reserved F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 IBM XTs and Compatibles Reserved Enter F11 F12 F13 F14 F15 New Line F16 F17 F18 Tab Field Forward Dele...

Страница 73: ...F13 F14 F15 New Line F16 F17 F18 Tab Field Forward Delete Field Exit Insert Clear Error Reset Home Print Back Space Back Tab F19 F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 Supported Interface Keys Supported Interface Keys NUL 00 SOH 01 STX 02 ETX 03 EOT 04 ENQ 05 ACK 06 BEL 07 BS 08 HT 09 LF 0A VT 0B FF 0C CR 0D SO 0E SI 0F DLE 10 DC1 11 DC2 12 DC3 13 DC4 14 NAK 15 SYN 16 ETB 17 CAN 18 EM 19 SUB 1A ESC 1B FS ...

Страница 74: ...T 0B FF 0C CR 0D SO 0E SI 0F DLE 10 DC1 11 DC2 12 DC3 13 DC4 14 NAK 15 SYN 16 ETB 17 CAN 18 EM 19 SUB 1A ESC 1B FS 1C GS 1D RS 1E US 1F Esprit 200 400 ANSI Esprit 200 400 ASCII Esprit 200 400 PC Reserved New Line N A N A N A N A N A New Line N A Tab N A Tab N A New Line N A Escape F11 Insert F13 Back Space Back Tab F12 F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 Reserved New Line N A N A N A N A N A New Line N...

Страница 75: ...ror Reset Home Delete Line Erase EOP Erase EOF Insert Line F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 Reserved Enter PF1 PF2 PF3 PF11 PF12 New Line PF4 TAB F13 F14 Remove New Line Insert Here Cursor Up Cursor Left Cursor Down Cursor Right Delete Print F15 F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 Supported Interface Keys Supported Interface Keys NUL 00 SOH 01 STX 02 ETX 03 EOT 04 ENQ 05 ACK 06 BEL 07 BS 08 HT 09 LF 0A V...

Страница 76: ...rsor Right Back Space Reserved Reserved F1 F2 F3 F4 F5 CTRL F1 F6 CTRL F2 F7 CTRL F3 F8 CTRL F4 F9 SHIFT F2 F10 SHIFT F3 Supported Interface Keys Supported Interface Keys NUL 00 SOH 01 STX 02 ETX 03 EOT 04 ENQ 05 ACK 06 BEL 07 BS 08 HT 09 LF 0A VT 0B FF 0C CR 0D SO 0E SI 0F DLE 10 DC1 11 DC2 12 DC3 13 DC4 14 NAK 15 SYN 16 ETB 17 CAN 18 EM 19 SUB 1A ESC 1B FS 1C GS 1D RS 1E US 1F WYSE WY 30 ...

Страница 77: ...mA Scanning 135mA 5700ALR 10 mA Idle 110 mA Scanning 145mA 5700ALR 60 to 90 mA Idle 165 to 200 mA Scanning 105 mA Idle 210 mA Scanning Operating 32 F to 104 F 0 C to 40 C Storage 40 F to 140 F 40 C to 60 C 5 to 95 non condensing 5 drops from 5 feet 1 5m to concrete 5700 A HD ALR 15 kV to any external surface FCC Class B CE LVD CDRH Class II Class IIIa for 5700ALR Parameter Specification Dimensions...

Страница 78: ...ll Welch Allyn terminals See chart below 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9 P2 P1 9 Pin Type D Female 10 Pin Modular Plug Pin 1 Pin 10 6 9 1 5 N C Enable Ground Good Read Data 5VDC Trigger SOS Cord Shield Laser Enable Supply Ground Turn on Good Read LED or Beeper Digital Bar Code Data Output 5 Volt Power Connection Trigger Signal to Decoder Start of Scan Braid P1 P2 View A A P2 connects to your ter...

Страница 79: ...ible with all Welch Allyn terminals See chart below 1 3 4 5 6 8 9 1 3 7 8 5 6 9 2 P2 P1 9 Pin Type D Female 10 Pin Modular Plug Pin 1 Pin 10 6 9 1 5 N C Enable Ground Good Read Data Trigger SOS Power Connection Laser Enable Supply Ground Turn on Good Read LED or Beeper Digital Bar Code Data Output Trigger Signal to Decoder Start of Scan 12VDC P1 P2 View A A P2 connects to your terminal P1 connects...

Страница 80: ...terminated with an 10 pin modular plug P1 and a 9 pin Type D Squeeze to release connector P2 that is compatible with all Welch Allyn terminals See chart below 4 3 6 7 2 8 7 4 2 P2 P1 9 Pin Type D Female 10 Pin Modular Plug Pin 1 Pin 10 6 9 1 5 Ground Prog 1 Barcode 5VDC Braid Supply Ground Tied to 5 Volt Power Bar Code Data Output 5 Volt Power Connection Cord Shield P1 P2 View A A P2 connects to y...

Страница 81: ...ompatible with all Welch Allyn terminals See chart below 9 7 8 4 3 5 6 2 SH 6 5 2 8 7 3 P2 9 Pin Type D Female 6 9 1 5 5VDC RTS Ground DTR RXD TXD Braid Clear to Send Data 5 Volt Power Connection Request to Send Data Supply Ground Data Terminal Ready Receive Data Serial Data to Scanner Transmit Data Serial Data from Scanner Cord Shield CTS P1 P2 View A A P2 connects to your terminal 470Ω 470Ω SH 1...

Страница 82: ...lug P1 and a 9 pin Type D Squeeze to release connector P2 that is compatible with all Welch Allyn terminals See chart below 3 4 5 6 7 2 9 1 2 3 5 6 7 8 9 P2 P1 9 Pin Type D Female 10 Pin Modular Plug Pin 1 Pin 10 6 9 1 5 Enable Ground Good Read Data 5VDC Trigger SOS Cord Shield Laser Enable Supply Ground Turn on Good Read LED or Beeper Digital Bar Code Data Output 5 Volt Power Connection Trigger S...

Страница 83: ...e the scanner in water The scanner s housing is not water tight Warning Do not use abrasive wipers or tissues on the scan window abrasive wipers may scratch the window Never use solvents alcohol or acetone on the housing or window solvents may damage the finish or the window Inspecting Cords and Connectors Inspect the scanner s interface cable and connector for wear or other signs of damage A badl...

Страница 84: ...cate the small hole on the side of the scanner handle near the base see Figure below Straighten one end of a paper clip Insert the end of the paper clip into the small hole and press in This depresses the retention tab releasing the connector Pull the connector out of the scanner handle while maintaining pressure on the paper clip Replace with the new cable Insert the connector into the opening at...

Страница 85: ...le reading your bar codes If the scanner isn t reading bar codes well check that the bar codes aren t smeared rough scratched or exhibiting voids aren t coated with frost or water droplets on the surface are enabled in the scanner or the decoder the scanner is connected to Is the bar code displayed but not entered The bar code is displayed on the host device correctly but you still have to press a...

Страница 86: ...ion 4 Symbology Menu The scanner won t read your bar code at all If the scanner will not read your bar code Try scanning the Sample Bar Codes found on the back cover of the User s Guide If the scanner reads the Sample Bar Codes check that your bar code is readable See Is the scanner having trouble reading your bar codes on the previous page If the scanner does not read the Sample Bar Codes either ...

Страница 87: ...ice return the unit to Welch Allyn postage paid with a copy of the dated purchase record attached In the United States please contact the Welch Allyn Product Service Department at the address telephone number listed below to obtain a Return Material Authorization number RMA Main Office Welch Allyn Inc Data Collection Division 4619 Jordan Road P O Box 187 Skaneateles Falls New York 13153 0187 Produ...

Страница 88: ...n Latin America please contact your Welch Allyn representative at address below or your local distributor Latin America Office Welch Allyn Ltd 5150 North Tamiami Trail Suite 302 Naples FL 34103 2821 Telephone 941 263 7600 Fax 941 263 9689 Help Desk If after reviewing the Troubleshooting Section you still need assistance installing or troubleshooting your Cordless System please call your Distributo...

Страница 89: ...yn Inc to the user at the time it is purchased from any of Welch Allyn Inc s Authorized Distributors Any attempt on the part of the user to disassemble or service the equipment shall void the warranty This warranty gives you specific legal rights and you may also have other rights which vary from state to state or country to country THE WARRANTIES SET FORTH HEREIN ARE IN LIEU OF ANY AND ALL OTHER ...

Страница 90: ...9 4 SCANTEAM 5700 User s Guide ...

Страница 91: ...s 1 Stop Bit Page 2 12 Baud Rate 9600 Page 2 11 Parity Even Page 2 12 Primary Prefix None Page 2 3 Primary Suffix None Page 2 3 Function Code Transmit Laser Voting Buffered Scans Intercharacter Delay Enable Disable Enable 00 x5mS Page 2 10 Page 2 9 Page 2 10 Page 2 8 Output Delays Interfunction Delay 00 x5mS Page 2 8 Intermessage Delay 00 x5mS Page 2 8 Reread Delay Low 175mS Page 2 9 Good Read Del...

Страница 92: ...e Up Pulse Disable Page 3 3 Country Code Selections Foreign Keyboards United States Page 3 4 Marker Beam 5700ALR only Off Page 3 2 AutoTrigger Enable Page 3 2 Output Polarity Black High Page 3 3 General Operating Menu Defaults Keyboard Selections AT Direct Connect Disable Page 3 5 NCR 7052 Keypad Layout 1 Telephone Page 3 5 Keyboard Style Prior to Software Rev 2 0 Style A Page 3 6 Software Rev 2 0...

Страница 93: ...ing Adaptive Page 4 2 Code 93 Selections Interleaved 2 of 5 Selections Code 39 On Page 4 4 Start Stop Characters Don t Transmit Page 4 4 Message Length Min 0 Max 48 Page 4 5 Check Character No Check Character Page 4 5 Full ASCII Enable Page 4 4 Append Disable Page 4 4 Decoding Adaptive Page 4 5 Code 93 On Page 4 6 Page 4 6 Message Length Min 0 Max 64 Interleaved 2 of 5 On Page 4 7 Message Length M...

Страница 94: ... Required 2 Check Digits Page 4 9 Message Length Min 4 Max 80 Page 4 9 Code 128 Selections Code 128 On Page 4 9 Page 4 9 Message Length Min 0 Max 80 Code 16K Selections Code 16K Off Page 4 11 Page 4 11 Message Length Min 0 Max 154 Code 49 Selections Code 49 Off Page 4 11 Page 4 11 Message Length Min 1 Max 80 Not in standard product Contact your Welch Allyn Sales Coordinator Code 128 Function Chara...

Страница 95: ...ength Min 4 Max 48 EAN JAN 13 On Page 4 12 EAN JAN 8 On Page 4 12 Check Digit Transmit Page 4 12 ISBN Disable Page 4 12 UPC Selections UPC A On Page 4 13 UPC E0 On Page 4 13 UPC E1 Off Page 4 13 Check Digit Transmit Page 4 13 Number System Transmit Page 4 13 Version E Expand Don t Expand Page 4 13 EAN UPC Addenda Selections EAN UPC Addenda Don t Require Page 4 14 Two Digit Addenda Disable Page 4 1...

Страница 96: ...SCANTEAM 5700 User s Guide ...

Страница 97: ......

Страница 98: ......

Страница 99: ...0 1 2 3 4 5 6 7 8 9 A B C D E F ...

Страница 100: ...34567890 Code 39 TEST SHEET Code 2 of 5 Matrix 2 of 5 123456 6543210 123456 9 Code 93 UPC A with 5 digit addenda 56098 0 12345 67890 5 EAN 13 9 780330 290951 5700 DO UG Rev K Skaneateles Falls New York 13153 0187 P O Box 187 4619 Jordan Road ...

Отзывы: