IMAGETEAM™ 2020/4620 System Manual
2 - 23
Wand Emulation Delay Between Blocks
This sets the delay time between data blocks.
Default = 50ms.
Wand Emulation Overall Checksum
When this option is turned on, a computed check character is added at the end
of the entire message. The check character is the character which when
Exclusive-OR’d with every preceding character of the message yields a result of
0x00 (00H).
Default = Off.
5ms
500ms
* 50ms
150ms
Wand Emulation Overall
Checksum On
* Wand Emulation Overall
Checksum Off