HESS-OF-S-10K
Empowering Energy Clean And Affordable
34
7. FaultandRemedy
7.1、Fault code
Alarm
Fault code
Fault
Code
Meaning
Does it
Affect the
outputs
Instructions
01
BatVoltLow
Yes
Battery under-voltage alarm
02
BatOverCurrSw
Yes
Battery discharge over-current, software protection
03
BatOpen
Yes
Battery disconnected alarm
04
BatLowEod
Yes
Battery under-voltage stop discharging alarm
05
BatOverCurrHw
Yes
Battery over-current hardware protection
06
BatOverVolt
Yes
Battery over-voltage protection
07
BusOverVoltHw
Yes
Busbar over-voltage hardware protection
08
BusOverVoltSw
Yes
Busbar over-voltage software protection
09
PvVoltHigh
Yes
PV input over-voltage protection
10
PvBoostOCSw
NO
Boost circuit over-current software protection
11
PvBoostOCHw
NO
Boost circuit over-current hardware protection
12
SpiCommErr
Yes
Master-slave chip SPI communication failure
13
OverloadBypass
Yes
Bypass overload protection
14
OverloadInverter
Yes
Inverter overload protection
15
AcOverCurrHw
Yes
Inverter over-current hardware protection
16
AuxDSpReqOffPWM
Yes
Slave chip request switch off failure
17
InvShort
Yes
Inverter short-circuit protection
18
Bussoftfailed
Yes
Busbar soft start failure