![background image](http://html1.mh-extra.com/html/han-bond/hb-series/hb-series_user-manualline_3483091046.webp)
www.han-bond.com
45
Calibration of spacing dislocation
Figure 9 spacing dislocation
Calibrate cartridge tilt misalignment
Ink box frame’s tilt lean to the right dislocation (FIG. 10 cases, left), tighten
the spring adjusting screw on the left of the ink holder.(Before adjustment, the 2
fixed screws on the right of the ink box rack must be all unscrewed)
Ink box frame’s tilt lean to the left dislocation (FIG. 10 cases, right), tighten
the spring adjusting screw on the right of the ink holder.(Before adjustment, the
2 fixed screws on the left of the ink box rack must be all unscrewed)
Figure 10 ink frame tilt adjustment