EN
17
TROUBLESHOOTING
Symptom/error function
Proposed action
The mini compressor does
not start.
Switch on the vehicle ignition and check that the 12 V DC outlet
is supplied with voltage.
Press the connector firmly in the 12 V DC outlet and twist it back
and forth.
Check the fuse for the 12 V DC outlet in the vehicle. The fuse
must be at least 15 A.
The mini compressor starts but
does not generate air pressure.
Check that the valve connection is firmly screwed on the tyre valve.
Check that the tyre is not leaking and that there is no leakage at
the valve connection.
The mini compressor is working
at low speed.
Overheating as a result of prolonged use. Switch off the
appliance and allow it to cool for 25 minutes.
Voltage too low, check the condition of the vehicle battery.